Evaluation of the Nautilus Smart Extracorporeal Membrane Oxygenation in Patients With Hemostatic Alteration: A Case Series.

IF 3.1 3区 医学 Q2 ENGINEERING, BIOMEDICAL ASAIO Journal Pub Date : 2025-02-01 Epub Date: 2024-06-14 DOI:10.1097/MAT.0000000000002252
Mauro Renghini, Debora Maddinelli, Anna Papeo, Carmine Puglia, Andrea Montisci, Sergio Cattaneo, Stefano Benussi
{"title":"Evaluation of the Nautilus Smart Extracorporeal Membrane Oxygenation in Patients With Hemostatic Alteration: A Case Series.","authors":"Mauro Renghini, Debora Maddinelli, Anna Papeo, Carmine Puglia, Andrea Montisci, Sergio Cattaneo, Stefano Benussi","doi":"10.1097/MAT.0000000000002252","DOIUrl":null,"url":null,"abstract":"<p><p>The intricate management of hemostatic disorders in extracorporeal membrane oxygenation (ECMO) assisted patients poses challenges, particularly when procoagulant administration is necessary. We hereby report the performance of the Nautilus* Smart ECMO Module in three patients with hemostatic disorders. We collected data from ECMO procedures with Nautilus* Smart ECMO Module and analyzed the performance: the operating pressures and resistance of the device in addition to the coagulation status of the patients. During the three procedures, partial pressure oxygen post-oxygenator (paO 2 ) stayed above 100 mm Hg and partial pressure carbon dioxide post-oxygenator (paCO 2 ) did not exceed 45 mm Hg. Membrane FiO 2 (fractional inspired O 2 ) did not exceed 75% and air flow remained within a 1:1 ratio with blood flow in veno-arterial ECMO (V-A) and within 1:2 in veno-venous ECMO (V-V). There was no evidence of excessive operating pressure for the device, with a pressure drop consistently below 28 mm Hg and a maximum peak resistance of 7 Δmm Hg/L/min. The Nautilus* Smart ECMO Module showed good performance in patients with hemostatic disorders despite the implications associated with procoagulant administration.</p>","PeriodicalId":8844,"journal":{"name":"ASAIO Journal","volume":" ","pages":"e28-e32"},"PeriodicalIF":3.1000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ASAIO Journal","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1097/MAT.0000000000002252","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/14 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The intricate management of hemostatic disorders in extracorporeal membrane oxygenation (ECMO) assisted patients poses challenges, particularly when procoagulant administration is necessary. We hereby report the performance of the Nautilus* Smart ECMO Module in three patients with hemostatic disorders. We collected data from ECMO procedures with Nautilus* Smart ECMO Module and analyzed the performance: the operating pressures and resistance of the device in addition to the coagulation status of the patients. During the three procedures, partial pressure oxygen post-oxygenator (paO 2 ) stayed above 100 mm Hg and partial pressure carbon dioxide post-oxygenator (paCO 2 ) did not exceed 45 mm Hg. Membrane FiO 2 (fractional inspired O 2 ) did not exceed 75% and air flow remained within a 1:1 ratio with blood flow in veno-arterial ECMO (V-A) and within 1:2 in veno-venous ECMO (V-V). There was no evidence of excessive operating pressure for the device, with a pressure drop consistently below 28 mm Hg and a maximum peak resistance of 7 Δmm Hg/L/min. The Nautilus* Smart ECMO Module showed good performance in patients with hemostatic disorders despite the implications associated with procoagulant administration.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
评估 Nautilus 智能体外膜氧合技术在止血功能改变患者中的应用:病例系列。
体外膜氧合(ECMO)辅助患者止血紊乱的复杂管理带来了挑战,尤其是在必须使用促凝血剂时。我们在此报告 Nautilus* 智能 ECMO 模块在三名止血障碍患者中的表现。我们收集了使用 Nautilus* 智能 ECMO 模块进行 ECMO 手术的数据,并分析了其性能:设备的工作压力和阻力以及患者的凝血状态。在三个手术过程中,氧合器后氧分压(paO2)保持在 100 毫米汞柱以上,氧合器后二氧化碳分压(paCO2)不超过 45 毫米汞柱。膜 FiO2(吸入氧气分数)不超过 75%,在静脉-动脉 ECMO(V-A)中,气流与血流的比例保持在 1:1;在静脉-静脉 ECMO(V-V)中,气流与血流的比例保持在 1:2。没有证据表明该设备工作压力过高,压降始终低于 28 mm Hg,最大峰值阻力为 7 Δmm Hg/L/min。Nautilus* 智能 ECMO 模块在有止血障碍的患者中表现良好,尽管使用促凝血剂会产生影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
ASAIO Journal
ASAIO Journal 医学-工程:生物医学
CiteScore
6.60
自引率
7.10%
发文量
651
审稿时长
4-8 weeks
期刊介绍: ASAIO Journal is in the forefront of artificial organ research and development. On the cutting edge of innovative technology, it features peer-reviewed articles of the highest quality that describe research, development, the most recent advances in the design of artificial organ devices and findings from initial testing. Bimonthly, the ASAIO Journal features state-of-the-art investigations, laboratory and clinical trials, and discussions and opinions from experts around the world. The official publication of the American Society for Artificial Internal Organs.
期刊最新文献
Platelet Activation and Severe Bleeding During Extracorporeal Carbon Dioxide Removal in Chronic Obstructive Pulmonary Disease Patients. Evaluation of the Nautilus Smart Extracorporeal Membrane Oxygenation in Patients With Hemostatic Alteration: A Case Series. Impella RP Flex: Rescue for the Failing Right Ventricle After Heart Transplantation-Case Report. Technique for Weaning From Peripheral Venopulmonary Extracorporeal Membrane Oxygenation in Combined Cardiopulmonary Failure. Extracorporeal Membrane Oxygenation in Amniotic Fluid Embolism: A Systematic Review of Case Reports.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1