Estudio piloto unicéntrico, doble ciego, aleatorizado y controlado con placebo para evaluar el uso de Canoxidin® en la prevención de la incrustación de la sonda en pacientes portadores de sonda permanente

IF 1.2 4区 医学 Q3 UROLOGY & NEPHROLOGY Actas urologicas espanolas Pub Date : 2024-11-01 DOI:10.1016/j.acuro.2024.05.005
{"title":"Estudio piloto unicéntrico, doble ciego, aleatorizado y controlado con placebo para evaluar el uso de Canoxidin® en la prevención de la incrustación de la sonda en pacientes portadores de sonda permanente","authors":"","doi":"10.1016/j.acuro.2024.05.005","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction and objectives</h3><div>Long-term use of an indwelling catheter is associated with complications such as catheter encrustation and infection. Canoxidin® is a novel oral treatment that can potentially prevent catheter encrustation, as it contains a urine acidifier and a combination of two crystallization inhibitors. This study aimed to evaluate the effects of Canoxidin® on catheter encrustation in patients with indwelling Foley catheters.</div></div><div><h3>Patients and methods</h3><div>This was a single-center, double-blind, randomized, placebo-controlled study. Neuro-urology patients aged ≥<!--> <!-->18<!--> <!-->years with an indwelling catheter (urethral or suprapubic) were randomized to treatment consisting of either Canoxidin® or placebo for one month. Foley catheters (two per patient, one before treatment and one after treatment) were removed for analysis of the presence and degree of encrustation.</div></div><div><h3>Results</h3><div>A total of 40 patients were enrolled and randomized, 28 of whom had analyzable catheters (13 assigned to Canoxidin® and 15 assigned to placebo). The patients had a mean age of 51.8<!--> <!-->years, and eight (28.6%) were female. Two patients (13.3%) in the placebo group and eight patients (61.5%) in the Canoxidin® group experienced an improvement (less encrustation). There was a significant association between Canoxidin® and improvement (odds ratio: 10.4, 95% confidence interval: 1.6 to 66.9, <em>P</em> <!-->=<!--> <!-->.016). No adverse effects attributable to the treatment were reported.</div></div><div><h3>Conclusions</h3><div>The overall rate of catheter encrustation was high among those with indwelling Foley catheters. One-month treatment with Canoxidin® reduced the formation of these encrustations, with an excellent short-term safety profile.</div></div>","PeriodicalId":7145,"journal":{"name":"Actas urologicas espanolas","volume":"48 9","pages":"Pages 658-664"},"PeriodicalIF":1.2000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Actas urologicas espanolas","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0210480624000743","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction and objectives

Long-term use of an indwelling catheter is associated with complications such as catheter encrustation and infection. Canoxidin® is a novel oral treatment that can potentially prevent catheter encrustation, as it contains a urine acidifier and a combination of two crystallization inhibitors. This study aimed to evaluate the effects of Canoxidin® on catheter encrustation in patients with indwelling Foley catheters.

Patients and methods

This was a single-center, double-blind, randomized, placebo-controlled study. Neuro-urology patients aged ≥ 18 years with an indwelling catheter (urethral or suprapubic) were randomized to treatment consisting of either Canoxidin® or placebo for one month. Foley catheters (two per patient, one before treatment and one after treatment) were removed for analysis of the presence and degree of encrustation.

Results

A total of 40 patients were enrolled and randomized, 28 of whom had analyzable catheters (13 assigned to Canoxidin® and 15 assigned to placebo). The patients had a mean age of 51.8 years, and eight (28.6%) were female. Two patients (13.3%) in the placebo group and eight patients (61.5%) in the Canoxidin® group experienced an improvement (less encrustation). There was a significant association between Canoxidin® and improvement (odds ratio: 10.4, 95% confidence interval: 1.6 to 66.9, P = .016). No adverse effects attributable to the treatment were reported.

Conclusions

The overall rate of catheter encrustation was high among those with indwelling Foley catheters. One-month treatment with Canoxidin® reduced the formation of these encrustations, with an excellent short-term safety profile.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
单中心、双盲、随机、安慰剂对照试验研究,评估 canoxidin® 在预防留置导管患者导管结壳方面的应用。
导言和目的长期使用留置导管会导致导管结壳和感染等并发症。Canoxidin® 是一种新型口服治疗药物,含有一种尿酸化剂和两种结晶抑制剂,有可能预防导管结壳。这项研究旨在评估 Canoxidin® 对留置 Foley 导管患者导管结壳的影响。患者和方法这是一项单中心、双盲、随机、安慰剂对照研究。年龄≥ 18 岁、留置导尿管(尿道或耻骨上导尿管)的神经泌尿科患者被随机分配接受为期一个月的 Canoxidin® 或安慰剂治疗。结果 共有 40 名患者参加了随机治疗,其中 28 人的导尿管可进行分析(13 人接受 Canoxidin® 治疗,15 人接受安慰剂治疗)。患者的平均年龄为 51.8 岁,其中 8 人(28.6%)为女性。安慰剂组的两名患者(13.3%)和 Canoxidin® 组的八名患者(61.5%)的病情有所改善(结壳减少)。Canoxidin®与病情改善之间存在明显关联(几率比:10.4,95% 置信区间:1.6 至 66.9,P = .016)。结论在留置 Foley 导管的患者中,导管结壳的总发生率很高。使用 Canoxidin® 进行为期一个月的治疗可减少这些包壳的形成,而且短期安全性极佳。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Actas urologicas espanolas
Actas urologicas espanolas UROLOGY & NEPHROLOGY-
CiteScore
1.90
自引率
0.00%
发文量
98
审稿时长
46 days
期刊介绍: Actas Urológicas Españolas is an international journal dedicated to urological diseases and renal transplant. It has been the official publication of the Spanish Urology Association since 1974 and of the American Urology Confederation since 2008. Its articles cover all aspects related to urology. Actas Urológicas Españolas, governed by the peer review system (double blinded), is published online in Spanish and English. Consequently, manuscripts may be sent in Spanish or English and bidirectional free cost translation will be provided.
期刊最新文献
El leaking pipeline y las brechas de género en Urología Controversias en el abordaje del cáncer de próstata: consenso de recomendaciones de expertos del norte de España Hacia el cribado poblacional del cáncer de próstata en España Evaluación de los cambios en la función sexual en pacientes sometidos a cirugía endoscópica de la litiasis del tracto urinario superior Producción científica en urología: un análisis bibliométrico de 20 años en Latinoamérica
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1