[Navigational bronchoscopy with tranbronchial cryobiopsy in differential diagnosis of peripheral pulmonary lesions].

Q4 Medicine Khirurgiya Pub Date : 2024-01-01 DOI:10.17116/hirurgia202406136
Ya O Chesalina, I Yu Shabalina, L A Semenova, I V Sivokozov
{"title":"[Navigational bronchoscopy with tranbronchial cryobiopsy in differential diagnosis of peripheral pulmonary lesions].","authors":"Ya O Chesalina, I Yu Shabalina, L A Semenova, I V Sivokozov","doi":"10.17116/hirurgia202406136","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To evaluate the efficacy and safety of tranbronchial cryobiopsy <b>(</b>TBCB) with 1.9-mm and 1.1-mm cryoprobes in patients with peripheral pulmonary lesions (PPLs).</p><p><strong>Material and methods: </strong>We analyzed 34 patients (mean age 60 years) with PPLs who underwent bronchoscopy with TBCB. Mean lesion size was 31.5 mm, upper lobe localization was predominant (47% of cases). CT signs of appropriate bronchus were identified in 79% (27/34) of cases. Manual branch tracking and virtual bronchoscopy (VB) were performed pre-procedurally, and radial endobronchial ultrasonography (rEBUS) was performed during bronchoscopy for accurate positioning of PPLs. TBCB was performed using 1.9-mm (<i>n</i>=19) or 1.1-mm (<i>n</i>=15) cryoprobes without fluoroscopic guidance. Incidence and severity of bleeding and pneumothorax were evaluated in all patients.</p><p><strong>Results: </strong>Total efficacy of TBCB was 76.5% (26/34): 78.9% (15/19) for 1.9-mm cryoprobe and 73.3% (11/15) for 1.1-mm cryoprobe (<i>p</i>=0.702). Efficacy depended on the presence of CT signs of bronchus (presence - 94%, absence 14.3%, <i>p</i><0.001) and PPL size (94% for PPL >30 mm and 58.8% for PPL <30 mm, <i>p</i>=0.016). Central probe position during rEBUS was associated with 94.7% diagnostic efficacy (18/19), adjacent probe position - 72.7% (8/11) (<i>p</i>=0.088). Bleeding grade 3 (Nasville) occurred in 5.8% (2/34) of cases, and no pneumothorax was observed.</p><p><strong>Conclusion: </strong>TBCB is an effective and safe diagnostic method for PPLs.</p>","PeriodicalId":35986,"journal":{"name":"Khirurgiya","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Khirurgiya","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17116/hirurgia202406136","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To evaluate the efficacy and safety of tranbronchial cryobiopsy (TBCB) with 1.9-mm and 1.1-mm cryoprobes in patients with peripheral pulmonary lesions (PPLs).

Material and methods: We analyzed 34 patients (mean age 60 years) with PPLs who underwent bronchoscopy with TBCB. Mean lesion size was 31.5 mm, upper lobe localization was predominant (47% of cases). CT signs of appropriate bronchus were identified in 79% (27/34) of cases. Manual branch tracking and virtual bronchoscopy (VB) were performed pre-procedurally, and radial endobronchial ultrasonography (rEBUS) was performed during bronchoscopy for accurate positioning of PPLs. TBCB was performed using 1.9-mm (n=19) or 1.1-mm (n=15) cryoprobes without fluoroscopic guidance. Incidence and severity of bleeding and pneumothorax were evaluated in all patients.

Results: Total efficacy of TBCB was 76.5% (26/34): 78.9% (15/19) for 1.9-mm cryoprobe and 73.3% (11/15) for 1.1-mm cryoprobe (p=0.702). Efficacy depended on the presence of CT signs of bronchus (presence - 94%, absence 14.3%, p<0.001) and PPL size (94% for PPL >30 mm and 58.8% for PPL <30 mm, p=0.016). Central probe position during rEBUS was associated with 94.7% diagnostic efficacy (18/19), adjacent probe position - 72.7% (8/11) (p=0.088). Bleeding grade 3 (Nasville) occurred in 5.8% (2/34) of cases, and no pneumothorax was observed.

Conclusion: TBCB is an effective and safe diagnostic method for PPLs.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[导航支气管镜与经支气管冷冻活组织检查在鉴别诊断周围肺部病变中的应用]。
目的评估使用 1.9 毫米和 1.1 毫米冷冻探针进行经支气管冷冻活检(TBCB)对肺周围病变(PPLs)患者的有效性和安全性:我们分析了 34 名接受支气管镜和 TBCB 检查的 PPLs 患者(平均年龄 60 岁)。病变平均大小为 31.5 毫米,上叶定位为主(占 47%)。79%的病例(27/34)发现了相应支气管的 CT 征象。术前进行了人工分支追踪和虚拟支气管镜检查(VB),支气管镜检查期间进行了径向支气管内超声检查(rEBUS),以准确定位 PPLs。TBCB使用1.9毫米(n=19)或1.1毫米(n=15)冷冻探针,无需透视引导。对所有患者的出血和气胸发生率和严重程度进行了评估:TBCB的总有效率为76.5%(26/34):结果:TBCB 的总有效率为 76.5%(26/34):1.9 毫米冷冻探针为 78.9%(15/19),1.1 毫米冷冻探针为 73.3%(11/15)(P=0.702)。疗效取决于是否存在支气管 CT 征象(存在 - 94%,不存在 14.3%,P30 毫米和 PPL 58.8% p=0.016)。rEBUS检查中,探头位于中心位置的诊断有效率为94.7%(18/19),探头位于邻近位置的诊断有效率为72.7%(8/11)(P=0.088)。5.8%的病例(2/34)出现3级出血(纳斯维尔),未观察到气胸:结论:TBCB 是一种有效、安全的 PPL 诊断方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Khirurgiya
Khirurgiya Medicine-Medicine (all)
CiteScore
0.70
自引率
0.00%
发文量
161
期刊介绍: Хирургия отдельных областей сердце, сосуды легкие пищевод молочная железа желудок и двенадцатиперстная кишка кишечник желчевыводящие пути печень
期刊最新文献
[Endoscopic stenting for malignant pancreatobiliary strictures]. [Ankle replacement for severe post-traumatic deformation of the distal tibia: a case report]. [Comparative analysis of in-hospital and long-term results of patients with acute dysfunction of coronary bypass grafts depending on treatment tactics]. [Efficacy and safety of surgical treatment of patients with pathological tortuosity of the internal carotid artery]. [Endoscopic vacuum therapy in minimally invasive treatment of esophageal perforations].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1