Syed Muhammad Saad, Abdul Rafiq Khan, Khalid Mohammed Khan, Ali Al-Othaim
{"title":"Problems in Commercial Kits of 25-Hydroxy Vitamin D and the Development of Simple, Robust and Faster HPLC Method.","authors":"Syed Muhammad Saad, Abdul Rafiq Khan, Khalid Mohammed Khan, Ali Al-Othaim","doi":"10.1093/chromsci/bmae042","DOIUrl":null,"url":null,"abstract":"<p><p>Vitamin D is a lipid-soluble compound that plays a key role in bone mineral metabolism. The commercial current kits and several published assay methods (High-performance liquid chromatography (HPLC) and Immunoassay) are complicated due to the use of multiple reagents, larger sample volume, high backpressure, longer extraction time, evaporation under nitrogen after extraction, significant interference and antibody cross-reactivity. Here we report a new HPLC method for the determination of 25-hydroxyvitamin D2 (25-OHD2) and 25-hydroxyvitamin D3 (25-OHD3) that is simple (no evaporation), rapid (10-minute run time) and robust. Serum sample (300 μl) is mixed with 300 μl acetonitrile containing lauraphenone as internal standard. After vortexing and centrifugation, the supernatant was loaded into C18 extraction cartridges, washed with 70% methanol and then eluted with 200 μl of a mixture of 70% ethanol and 30% isopropyl alcohol (IPA). The eluent was mixed with 50 μl of water and injected into the HPLC-UV system for analysis. The method proved to be linear in the range of 10-750 nmol/L of 25-OHD2 and 25-OHD3. The intra- and inter-assay precision was less than 10 for both compounds at four different concentrations. The method was compared with (LC-MS/MS) and the correlation coefficients (R2) were 0.9454 and 0.9673 for 25-OHD2 and 25-OHD3 respectively. The proposed HPLC method is simple, rapid, robust and free from the most common problems encountered with commercial kits. It can be used in a high-volume laboratory that uses the HPLC method for the simultaneous determination of 25-OHD2 and 25-OHD3 in serum samples.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-06-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1093/chromsci/bmae042","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Vitamin D is a lipid-soluble compound that plays a key role in bone mineral metabolism. The commercial current kits and several published assay methods (High-performance liquid chromatography (HPLC) and Immunoassay) are complicated due to the use of multiple reagents, larger sample volume, high backpressure, longer extraction time, evaporation under nitrogen after extraction, significant interference and antibody cross-reactivity. Here we report a new HPLC method for the determination of 25-hydroxyvitamin D2 (25-OHD2) and 25-hydroxyvitamin D3 (25-OHD3) that is simple (no evaporation), rapid (10-minute run time) and robust. Serum sample (300 μl) is mixed with 300 μl acetonitrile containing lauraphenone as internal standard. After vortexing and centrifugation, the supernatant was loaded into C18 extraction cartridges, washed with 70% methanol and then eluted with 200 μl of a mixture of 70% ethanol and 30% isopropyl alcohol (IPA). The eluent was mixed with 50 μl of water and injected into the HPLC-UV system for analysis. The method proved to be linear in the range of 10-750 nmol/L of 25-OHD2 and 25-OHD3. The intra- and inter-assay precision was less than 10 for both compounds at four different concentrations. The method was compared with (LC-MS/MS) and the correlation coefficients (R2) were 0.9454 and 0.9673 for 25-OHD2 and 25-OHD3 respectively. The proposed HPLC method is simple, rapid, robust and free from the most common problems encountered with commercial kits. It can be used in a high-volume laboratory that uses the HPLC method for the simultaneous determination of 25-OHD2 and 25-OHD3 in serum samples.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.