Fluorescein-conjugated hyaluronic acid enables visualization of retained ophthalmic viscosurgical device in anterior chamber.

IF 2.6 3区 医学 Q2 OPHTHALMOLOGY Journal of cataract and refractive surgery Pub Date : 2024-10-01 DOI:10.1097/j.jcrs.0000000000001503
Erick E Rocher, Allen O Eghrari
{"title":"Fluorescein-conjugated hyaluronic acid enables visualization of retained ophthalmic viscosurgical device in anterior chamber.","authors":"Erick E Rocher, Allen O Eghrari","doi":"10.1097/j.jcrs.0000000000001503","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To develop and assess the utility of an ophthalmic viscosurgical device (OVD) manufactured with fluorescein-conjugated hyaluronic acid (conjHA).</p><p><strong>Setting: </strong>Department of Biomedical Engineering and the Wilmer Eye Institute, Johns Hopkins University and School of Medicine, Baltimore, Maryland.</p><p><strong>Design: </strong>Laboratory study.</p><p><strong>Methods: </strong>ConjHA and unconjugated HA (unconjHA) at varied ratios were used to produce OVD (conjOVD) with varied fluorescence intensity. The conjHA:unconjHA ratio was optimized to maximize clarity under white light and fluorescence intensity under cobalt blue light (CBL), allowing for conditional visualization. The effect of conjugation on conjOVD viscosity was assessed by rotational rheometry. Intraocular lenses (IOLs) were immersed in conjOVD for 4 hours to assess staining of IOLs. A proof-of-concept study was performed in ex vivo porcine eyes. After injection and visualization, the OVDs were removed from the eyes by irrigation/aspiration (I/A).</p><p><strong>Results: </strong>0.5 mg/mL of conjHA (degree of substitution = 0.005) enabled robust fluorescence of conjOVD under CBL. Fluorescein conjugation did not significantly affect conjOVD viscosity ( P > .05 for mean difference in viscosity at all shear rates tested). No staining of IOLs was appreciated. ConjOVD was visualized under CBL when injected ex vivo and maintained clarity of the anterior chamber under white light. Importantly, conjHA enabled delineation of retained OVD after I/A.</p><p><strong>Conclusions: </strong>Use of OVD composed of fluorescein-conjugated HA is a feasible method to enable conditional visualization of OVD intraoperatively without nonspecific staining of ocular structures. Further development of this technology may enable accelerated OVD removal in ocular surgery or decreased OVD retention postoperatively.</p>","PeriodicalId":15214,"journal":{"name":"Journal of cataract and refractive surgery","volume":" ","pages":"1058-1064"},"PeriodicalIF":2.6000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of cataract and refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/j.jcrs.0000000000001503","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To develop and assess the utility of an ophthalmic viscosurgical device (OVD) manufactured with fluorescein-conjugated hyaluronic acid (conjHA).

Setting: Department of Biomedical Engineering and the Wilmer Eye Institute, Johns Hopkins University and School of Medicine, Baltimore, Maryland.

Design: Laboratory study.

Methods: ConjHA and unconjugated HA (unconjHA) at varied ratios were used to produce OVD (conjOVD) with varied fluorescence intensity. The conjHA:unconjHA ratio was optimized to maximize clarity under white light and fluorescence intensity under cobalt blue light (CBL), allowing for conditional visualization. The effect of conjugation on conjOVD viscosity was assessed by rotational rheometry. Intraocular lenses (IOLs) were immersed in conjOVD for 4 hours to assess staining of IOLs. A proof-of-concept study was performed in ex vivo porcine eyes. After injection and visualization, the OVDs were removed from the eyes by irrigation/aspiration (I/A).

Results: 0.5 mg/mL of conjHA (degree of substitution = 0.005) enabled robust fluorescence of conjOVD under CBL. Fluorescein conjugation did not significantly affect conjOVD viscosity ( P > .05 for mean difference in viscosity at all shear rates tested). No staining of IOLs was appreciated. ConjOVD was visualized under CBL when injected ex vivo and maintained clarity of the anterior chamber under white light. Importantly, conjHA enabled delineation of retained OVD after I/A.

Conclusions: Use of OVD composed of fluorescein-conjugated HA is a feasible method to enable conditional visualization of OVD intraoperatively without nonspecific staining of ocular structures. Further development of this technology may enable accelerated OVD removal in ocular surgery or decreased OVD retention postoperatively.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
荧光素共轭透明质酸可用于观察前房中留置的眼科粘弹性手术器械。
目的:开发并评估使用荧光素结合透明质酸(conjugated hyaluronic acid,conjHA)制造的眼科粘弹性手术器械(OVD)的实用性:美国马里兰州巴尔的摩市约翰霍普金斯大学医学院生物医学工程系和威尔莫眼科研究所:设计:实验室研究:方法:使用不同比例的结合HA和非结合HA(unconjHA)生产具有不同荧光强度的OVD(conjOVD)。共轭 HA 与未共轭 HA 的比例经过优化,在白光和钴蓝光(CBL)下可最大限度地提高清晰度和荧光强度,从而实现有条件的可视化。通过旋转流变仪评估了共轭对 conjOVD 粘度的影响。将人工晶体(IOL)浸泡在 conjOVD 中 4 小时,以评估人工晶体的染色情况。在活体猪眼中进行了概念验证研究。注射和显影后,通过灌洗/吸气(I/A)将 OVD 从猪眼中取出:结果:0.5 毫克/毫升的 conjHA(取代度=0.005)可使 conjOVD 在 CBL 下发出强荧光。荧光素共轭对 conjOVD 的粘度没有明显影响(在所有测试的剪切率下,粘度的平均差异均大于 0.05)。人工晶体未被染色。体内注射时,在 CBL 下可观察到 conjOVD,在白光下可保持前房的清晰度。重要的是,ConjOVD 能够在 I/A 后对保留的 OVD 进行划定:结论:使用由荧光素结合的 HA 组成的 OVD 是一种可行的方法,可在术中有条件地观察 OVD,而不会对眼部结构造成非特异性染色。这项技术的进一步发展可能会加快眼科手术中OVD的清除速度或减少术后OVD的滞留。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
5.60
自引率
14.30%
发文量
259
审稿时长
8.5 weeks
期刊介绍: The Journal of Cataract & Refractive Surgery (JCRS), a preeminent peer-reviewed monthly ophthalmology publication, is the official journal of the American Society of Cataract and Refractive Surgery (ASCRS) and the European Society of Cataract and Refractive Surgeons (ESCRS). JCRS publishes high quality articles on all aspects of anterior segment surgery. In addition to original clinical studies, the journal features a consultation section, practical techniques, important cases, and reviews as well as basic science articles.
期刊最新文献
Ocular Shape of Cataract with Retinitis Pigmentosa: A Case-Control Study. Intraocular Lens Rotational Stability after Cataract Surgery with and without Primary Posterior Continuous Curvilinear Capsulorrhexis. Risk of Zonular Dialysis in Fellow-Eye Cataract Surgeries: A Multicenter Comparative Study. Accuracy of intraocular lens power calculation in patients with endothelial dystrophy without edema. Analysis of the ESCRS calculator's prediction accuracy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1