[Effect of zirconia personalized gingival penetration on peri-implant soft and hard tissue of thin gingival biotypes in the anterior region: a retrospective study].

Y R Wang, M Zhang, P Chen, S B Li, H B Lu, M Y Zeng, Y Zeng, M D Rong
{"title":"[Effect of zirconia personalized gingival penetration on peri-implant soft and hard tissue of thin gingival biotypes in the anterior region: a retrospective study].","authors":"Y R Wang, M Zhang, P Chen, S B Li, H B Lu, M Y Zeng, Y Zeng, M D Rong","doi":"10.3760/cma.j.cn112144-20240316-00112","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objective:</b> To investigate the effect of zirconia personalized gingival structure on peri-implant soft and hard tissue stability after single-tooth implant restorations in patients with thin gingival biotypes in the anterior region, with a view to provide a clinical guideline. <b>Methods:</b> This retrospective study included 20 patients with thin gingival biotype and implant restorations in the anterior region. These patients included 9 males and 11 females, and the age was (35.2± 10.3) years. The patients were from the Department of Periodontal Implantology, Stomatology Hospital, Southern Medical University from January 2018 to December 2022. Computer-aided design/computer-aided manufacturing (CAD/CAM) techniques were used to fabricate a titanium base zirconia personalized gingival structure to maintain the soft-tissue perforated gingival contour of the anterior esthetic zone. This structure consists of two modalities: titanium base + zirconia outer crown or titanium base personalized zirconia abutment + zirconia outer crown. Clinical outcomes were recorded immediately and after delivery of the final restorations. Implant retention was recorded, esthetic scoring was performed using the pink esthetic index, the amount of bone resorption at the implant margins was measured based on digitized apical radiographs, and periodontal health was evaluated using the modified plaque index and the modified bleeding index. <b>Results:</b> The survival rate of the 20 implants was 100% after 3 years of wearing the final restorations, with a pink aesthetic score of 9.3±0.9. Bone resorption at the proximal and distal mesial margins of the implants was 0.09 (-0.21, 0.20) mm, 0.17 (-0.12, 0.27) mm after 3 years, respectively, and the difference was not statistically significant when compared to bone resorption immediately after placement of the final restoration [0(0, 0) mm] (<i>Z</i>=-1.03, <i>P</i>=0.394; <i>Z</i>=-2.05, <i>P</i>=0.065). <b>Conclusions:</b> Zirconia personalized gingival structure maintains the stability of peri-implant hard and soft tissues of thin gingival biotypes in the anterior region.</p>","PeriodicalId":23965,"journal":{"name":"中华口腔医学杂志","volume":"59 7","pages":"690-695"},"PeriodicalIF":0.0000,"publicationDate":"2024-07-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华口腔医学杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/cma.j.cn112144-20240316-00112","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To investigate the effect of zirconia personalized gingival structure on peri-implant soft and hard tissue stability after single-tooth implant restorations in patients with thin gingival biotypes in the anterior region, with a view to provide a clinical guideline. Methods: This retrospective study included 20 patients with thin gingival biotype and implant restorations in the anterior region. These patients included 9 males and 11 females, and the age was (35.2± 10.3) years. The patients were from the Department of Periodontal Implantology, Stomatology Hospital, Southern Medical University from January 2018 to December 2022. Computer-aided design/computer-aided manufacturing (CAD/CAM) techniques were used to fabricate a titanium base zirconia personalized gingival structure to maintain the soft-tissue perforated gingival contour of the anterior esthetic zone. This structure consists of two modalities: titanium base + zirconia outer crown or titanium base personalized zirconia abutment + zirconia outer crown. Clinical outcomes were recorded immediately and after delivery of the final restorations. Implant retention was recorded, esthetic scoring was performed using the pink esthetic index, the amount of bone resorption at the implant margins was measured based on digitized apical radiographs, and periodontal health was evaluated using the modified plaque index and the modified bleeding index. Results: The survival rate of the 20 implants was 100% after 3 years of wearing the final restorations, with a pink aesthetic score of 9.3±0.9. Bone resorption at the proximal and distal mesial margins of the implants was 0.09 (-0.21, 0.20) mm, 0.17 (-0.12, 0.27) mm after 3 years, respectively, and the difference was not statistically significant when compared to bone resorption immediately after placement of the final restoration [0(0, 0) mm] (Z=-1.03, P=0.394; Z=-2.05, P=0.065). Conclusions: Zirconia personalized gingival structure maintains the stability of peri-implant hard and soft tissues of thin gingival biotypes in the anterior region.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[氧化锆个性化牙龈穿透对前牙区薄牙龈生物型种植体周围软组织和硬组织的影响:一项回顾性研究]。
目的研究氧化锆个性化牙龈结构对前牙区薄型牙龈患者单牙种植修复后种植体周围软组织和硬组织稳定性的影响,以期为临床提供指导。研究方法这项回顾性研究纳入了 20 名牙龈生物型较薄并在前牙区域进行过种植修复的患者。其中男性 9 人,女性 11 人,年龄为(35.2±10.3)岁。患者来自南方医科大学口腔医院牙周种植科,时间为2018年1月至2022年12月。采用计算机辅助设计/计算机辅助制造(CAD/CAM)技术制作钛基氧化锆个性化牙龈结构,以保持前牙美学区的软组织穿孔牙龈轮廓。该结构包括两种模式:钛基底+氧化锆外冠或钛基底个性化氧化锆基台+氧化锆外冠。临床结果在最终修复体交付时和交付后进行记录。记录种植体的固位情况,使用粉色美学指数进行美学评分,根据数字化根尖X光片测量种植体边缘的骨吸收量,使用改良菌斑指数和改良出血指数评估牙周健康状况。结果显示20颗种植体在佩戴最终修复体3年后的存活率为100%,粉色美学评分为9.3±0.9。种植体近端和远端中线边缘的骨吸收在 3 年后分别为 0.09 (-0.21, 0.20) mm 和 0.17 (-0.12, 0.27) mm,与最终修复体植入后即刻(0)的骨吸收相比,差异无统计学意义(Z=-1.03,P=0.394;Z=-2.05,P=0.065)。结论氧化锆个性化牙龈结构可以保持前牙区薄牙龈生物型种植体周围软硬组织的稳定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
中华口腔医学杂志
中华口腔医学杂志 Medicine-Medicine (all)
CiteScore
0.90
自引率
0.00%
发文量
9692
期刊介绍: Founded in August 1953, Chinese Journal of Stomatology is a monthly academic journal of stomatology published publicly at home and abroad, sponsored by the Chinese Medical Association and co-sponsored by the Chinese Stomatology Association. It mainly reports the leading scientific research results and clinical diagnosis and treatment experience in the field of oral medicine, as well as the basic theoretical research that has a guiding role in oral clinical practice and is closely combined with oral clinical practice. Chinese Journal of Over the years, Stomatology has been published in Medline, Scopus database, Toxicology Abstracts Database, Chemical Abstracts Database, American Cancer database, Russian Abstracts database, China Core Journal of Science and Technology, Peking University Core Journal, CSCD and other more than 20 important journals at home and abroad Physical medicine database and retrieval system included.
期刊最新文献
[Artificial intelligence-supported clear aligner orthodontic technology]. [Assessment of optical coherence tomography and optical coherence microscope for oral cancer diagnosis: a clinical study]. [Customized lingual orthodontics: clinical features and difficulties]. [Development and application of digital technology in craniomaxillofacial surgery]. [Effect of loading angle and fabrication materials on stress distribution with periodontal splint in compromised periodontal tissues: a finite element study].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1