{"title":"Accuracy and clinical role of digital templating for total knee arthroplasty performed on haemophilic knees","authors":"Arman Vahabi,&nbsp;Erdem Er,&nbsp;Elcil Kaya Biçer,&nbsp;Fahri Şahin,&nbsp;Kaan Kavakli,&nbsp;Semih Aydoğdu","doi":"10.1111/hae.15072","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Introduction</h3>\n \n <p>In total knee arthroplasty (TKA), choosing the correct implant size is important. There is lack of data on accuracy of templating on haemophilic knees. Our aim was to test the accuracy of 2D digital templating for TKA on haemophilic arthropathy (HA) of knee.</p>\n </section>\n \n <section>\n \n <h3> Materials and Methods</h3>\n \n <p>TKAs performed on HA between January 2011 and January 2022 were screened. Osteoarthritis (OA) group was created as control group by a one-to-one matching regarding type of implant used. Intra- and interobserver correlations were measured in HA, then correlation between templated and implanted sizes was investigated in four assessments (femur AP, femur lateral, tibia AP, tibia lateral), then compared with OA group. Fifty-eight knees in each group included.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Regarding intraobserver correlation in HA, there was excellent correlation for femur AP [.93 (.73–.98)], femur lateral [.98 (.91–.99)], and tibia AP (1.0) templating. Regarding interobserver correlation in HA, excellent correlation was observed for femur lateral [.93 (.74–.98)] and tibia AP templating [.90 (.65–.97)]. Regarding correlation of templated and applied sizes in HA; tibia AP, tibia lateral and femur lateral templating showed good correlation [.81 (.70–.89), .86 (.77–.91), .79 (.67–.87) while femur AP templating showed moderate correlation [.67 (.50–.79)]. Comparing HA and OA, there was no difference in correlation levels regarding femur AP, femur lateral, tibia AP and tibia lateral templating (<i>p</i> = .056, <i>p</i> = .781, <i>p</i> = .761, <i>p</i> = .083, respectively).</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>Although 2D digital templating shows comparable correlation in HA and OA, clinical applicability of templating on HA appears to be limited in its current state.</p>\n </section>\n </div>","PeriodicalId":12819,"journal":{"name":"Haemophilia","volume":"30 4","pages":"1043-1049"},"PeriodicalIF":3.0000,"publicationDate":"2024-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/hae.15072","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Haemophilia","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/hae.15072","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction

In total knee arthroplasty (TKA), choosing the correct implant size is important. There is lack of data on accuracy of templating on haemophilic knees. Our aim was to test the accuracy of 2D digital templating for TKA on haemophilic arthropathy (HA) of knee.

Materials and Methods

TKAs performed on HA between January 2011 and January 2022 were screened. Osteoarthritis (OA) group was created as control group by a one-to-one matching regarding type of implant used. Intra- and interobserver correlations were measured in HA, then correlation between templated and implanted sizes was investigated in four assessments (femur AP, femur lateral, tibia AP, tibia lateral), then compared with OA group. Fifty-eight knees in each group included.

Results

Regarding intraobserver correlation in HA, there was excellent correlation for femur AP [.93 (.73–.98)], femur lateral [.98 (.91–.99)], and tibia AP (1.0) templating. Regarding interobserver correlation in HA, excellent correlation was observed for femur lateral [.93 (.74–.98)] and tibia AP templating [.90 (.65–.97)]. Regarding correlation of templated and applied sizes in HA; tibia AP, tibia lateral and femur lateral templating showed good correlation [.81 (.70–.89), .86 (.77–.91), .79 (.67–.87) while femur AP templating showed moderate correlation [.67 (.50–.79)]. Comparing HA and OA, there was no difference in correlation levels regarding femur AP, femur lateral, tibia AP and tibia lateral templating (p = .056, p = .781, p = .761, p = .083, respectively).

Conclusion

Although 2D digital templating shows comparable correlation in HA and OA, clinical applicability of templating on HA appears to be limited in its current state.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
血友病膝关节全膝关节置换术数字模板的准确性和临床作用
导言:在全膝关节置换术(TKA)中,选择正确的植入物尺寸非常重要。目前还缺乏有关嗜血膝关节模板制作准确性的数据。我们的目的是测试二维数字模板对嗜血细胞性膝关节病(HA)的 TKA 的准确性。骨关节炎(OA)组作为对照组,在所用植入物类型上进行一对一匹配。在HA组中测量观察者内部和观察者之间的相关性,然后在四项评估(股骨AP、股骨侧、胫骨AP、胫骨侧)中调查模板尺寸和植入尺寸之间的相关性,然后与OA组进行比较。结果关于HA的观察者内相关性,股骨AP[.93(.73-.98)]、股骨侧[.98(.91-.99)]和胫骨AP(1.0)模板的相关性极佳。在医管局的观察者间相关性方面,股骨外侧[.93(.74-.98)]和胫骨AP模板[.90(.65-.97)]的相关性极佳。关于HA中模板和应用尺寸的相关性,胫骨AP、胫骨外侧和股骨外侧模板显示出良好的相关性[.81(.70-.89)、.86(.77-.91)、.79(.67-.87)],而股骨AP模板显示出中等相关性[.67(.50-.79)]。结论虽然二维数字模板在HA和OA中显示出相似的相关性,但目前模板在HA中的临床应用似乎还很有限。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Haemophilia
Haemophilia 医学-血液学
CiteScore
6.50
自引率
28.20%
发文量
226
审稿时长
3-6 weeks
期刊介绍: Haemophilia is an international journal dedicated to the exchange of information regarding the comprehensive care of haemophilia. The Journal contains review articles, original scientific papers and case reports related to haemophilia care, with frequent supplements. Subjects covered include: clotting factor deficiencies, both inherited and acquired: haemophilia A, B, von Willebrand''s disease, deficiencies of factor V, VII, X and XI replacement therapy for clotting factor deficiencies component therapy in the developing world transfusion transmitted disease haemophilia care and paediatrics, orthopaedics, gynaecology and obstetrics nursing laboratory diagnosis carrier detection psycho-social concerns economic issues audit inherited platelet disorders.
期刊最新文献
Cross-Cultural Translation of the Adolescent Menstrual Bleeding Questionnaire (AMBQ). Research Letter: Patient Attitudes Towards Haemophilia Gene Therapy at a US Haemophilia Treatment Center. Effects of physical therapy on health-related quality of life in patients with haemophilia: A systematic review and meta-analysis. A phase 1/2 safety and efficacy study of TAK-754 gene therapy: The challenge of achieving durable factor VIII expression in haemophilia A clinical trials. Issue Information
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1