“Turn-on” fluorescence sensing for sensitively detecting Cr(vi) via a guest exchange process in Cu NCs@MIL-101 composites†

IF 2.6 3区 化学 Q2 CHEMISTRY, ANALYTICAL Analytical Methods Pub Date : 2024-06-24 DOI:10.1039/D4AY00956H
Huijing Chen, Bo Peng, Ping Zhang, Ying Yang and Xue Hu
{"title":"“Turn-on” fluorescence sensing for sensitively detecting Cr(vi) via a guest exchange process in Cu NCs@MIL-101 composites†","authors":"Huijing Chen, Bo Peng, Ping Zhang, Ying Yang and Xue Hu","doi":"10.1039/D4AY00956H","DOIUrl":null,"url":null,"abstract":"<p >Copper nanoclusters (Cu NCs) are a new fluorescent material that is often used for determining metal ions, but most sensing systems are based on the “turn-off” model. Here, a “turn-on” model of fluorescence sensing for the detection of Cr(<small>VI</small>) was developed based on Cu NCs@MIL-101 composites. The Cu NCs@MIL-101 composites were synthesized from a simple mixture of Cu NCs and MIL-101(Cr), in which the Cu NCs were uniformly distributed in MIL-101(Cr). Notably, the fluorescence intensity of Cu NCs@MIL-101 was significantly weakened due to the internal filtration effect (IFE) of MIL-101. When Cr(<small>VI</small>) was introduced, the fluorescence of Cu NCs@MIL-101 was recovered by the guest exchange process between Cr(<small>VI</small>) and the Cu NCs, which overcame the IFE of Cu NCs@MIL-101. Based on this, a “turn-on” fluorescence probe was successfully constructed for the quantitative detection of Cr(<small>VI</small>) with two linear ranges of 0.05–1 μM and 1–20 μM, and a low detection limit of 0.05 μM. The proposed fluorescence probe possessed excellent selectivity and anti-interference ability, and was successfully applied for the detection of Cr(<small>VI</small>) in real water samples with satisfactory results. This study provides a new approach for the analytical application of Cu NCs.</p>","PeriodicalId":64,"journal":{"name":"Analytical Methods","volume":" 28","pages":" 4835-4842"},"PeriodicalIF":2.6000,"publicationDate":"2024-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Methods","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2024/ay/d4ay00956h","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Copper nanoclusters (Cu NCs) are a new fluorescent material that is often used for determining metal ions, but most sensing systems are based on the “turn-off” model. Here, a “turn-on” model of fluorescence sensing for the detection of Cr(VI) was developed based on Cu NCs@MIL-101 composites. The Cu NCs@MIL-101 composites were synthesized from a simple mixture of Cu NCs and MIL-101(Cr), in which the Cu NCs were uniformly distributed in MIL-101(Cr). Notably, the fluorescence intensity of Cu NCs@MIL-101 was significantly weakened due to the internal filtration effect (IFE) of MIL-101. When Cr(VI) was introduced, the fluorescence of Cu NCs@MIL-101 was recovered by the guest exchange process between Cr(VI) and the Cu NCs, which overcame the IFE of Cu NCs@MIL-101. Based on this, a “turn-on” fluorescence probe was successfully constructed for the quantitative detection of Cr(VI) with two linear ranges of 0.05–1 μM and 1–20 μM, and a low detection limit of 0.05 μM. The proposed fluorescence probe possessed excellent selectivity and anti-interference ability, and was successfully applied for the detection of Cr(VI) in real water samples with satisfactory results. This study provides a new approach for the analytical application of Cu NCs.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
通过 Cu NCs@MIL-101 复合材料中的客体交换过程灵敏检测 Cr(Ⅵ)的 "开启式 "荧光传感技术
纳米铜簇(Cu NCs)作为一种新型荧光材料经常被用于检测金属离子,但大多数都是基于 "关闭 "模式。本文基于 Cu NCs@MIL-101 复合材料,开发了一种用于检测 Cr(Ⅵ)的 "开启 "模式荧光传感平台。Cu NCs@MIL-101 由 Cu NCs 和 MIL-101(Cr)简单混合合成,其中 Cu NCs 均匀分布在 MIL-101(Cr)中。值得注意的是,由于 MIL-101 的内部过滤效应(IFE),Cu NCs@MIL-101 的荧光强度明显减弱。当引入铬(Ⅵ)时,Cu NCs@MIL-101 的荧光将通过铬(Ⅵ)与 Cu NCs 的客体交换过程恢复,从而克服 Cu NCs@MIL-101 的内滤效应。在此基础上,成功构建了一种用于定量检测铬(Ⅵ)的 "开启式 "荧光探针,其线性范围分别为 0.05-1 μM 和 1-20 μM,检测限低至 0.05 μM。该荧光探针具有良好的选择性和抗干扰能力,已成功应用于实际水样中铬(Ⅵ)的检测,结果令人满意。该研究为 Cu NCs 的分析应用提供了一种新方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Analytical Methods
Analytical Methods CHEMISTRY, ANALYTICAL-FOOD SCIENCE & TECHNOLOGY
CiteScore
5.10
自引率
3.20%
发文量
569
审稿时长
1.8 months
期刊介绍: Early applied demonstrations of new analytical methods with clear societal impact
期刊最新文献
One-pot iron determination in fortified flours using thymol-1,10-phenanthroline deep eutectic solvent and smartphone-based digital image photometry. Breaking the bottlenecks in nanozyme-antibody conjugate preparation: challenges, optimization strategies, and applications of in vitro diagnostics. A low-cost, high-throughput DNA quantification system using light pipe arrays for parallel fluorescence measurement. Accurate quantification of polyester in textiles through complete depolymerisation and HPLC. Imaging of individual concanavalin a proteins by atomic force microscopy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1