Graphene oxide-based probe for detecting deltamethrin and emamectin benzoate pesticides in agricultural run-off†

IF 4.3 3区 材料科学 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC ACS Applied Electronic Materials Pub Date : 2024-07-04 DOI:10.1039/D4EW00328D
Suryyia Manzoor, Muhammad Hayat, Hina Raza, Noureddine Elboughdiri, Muhammad Imran Khan, Zeeshan Ali, Ayesha Javed, Nadeem Raza, Fahad Abdulaziz and Abdallah Shanableh
{"title":"Graphene oxide-based probe for detecting deltamethrin and emamectin benzoate pesticides in agricultural run-off†","authors":"Suryyia Manzoor, Muhammad Hayat, Hina Raza, Noureddine Elboughdiri, Muhammad Imran Khan, Zeeshan Ali, Ayesha Javed, Nadeem Raza, Fahad Abdulaziz and Abdallah Shanableh","doi":"10.1039/D4EW00328D","DOIUrl":null,"url":null,"abstract":"<p >Insecticides adversely affect aquatic ecosystems due to prolonged exposure, persistent nature, and bioaccumulation. Deltamethrin and emamectin benzoate are pesticides that can enter water resources <em>via</em> fruits and vegetables, causing severe concerns to living organisms. This study focuses on fabricating a probe for the selective solid-phase microextraction of targeted pesticides from agricultural runoff. The sorbent was designed using the novel dual-template graphene oxide-based molecularly imprinted organically modified silica. In this study, we investigated the effect of different parameters (time, pH, and temperature) on the efficacy of the sorbent using response surface methodology (central composite design). The sorbent exhibited high binding capacities of 42 mg g<small><sup>−1</sup></small> and 27 mg g<small><sup>−1</sup></small> for deltamethrin and emamectin benzoate, respectively. Percentage recoveries were 93.3% and 94.2% for deltamethrin and emamectin benzoate, respectively. The selective detection of deltamethrin and emamectin benzoate from agricultural runoff was confirmed by real-sample analysis using high-performance liquid chromatography.</p>","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2024-07-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"93","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2024/ew/d4ew00328d","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Insecticides adversely affect aquatic ecosystems due to prolonged exposure, persistent nature, and bioaccumulation. Deltamethrin and emamectin benzoate are pesticides that can enter water resources via fruits and vegetables, causing severe concerns to living organisms. This study focuses on fabricating a probe for the selective solid-phase microextraction of targeted pesticides from agricultural runoff. The sorbent was designed using the novel dual-template graphene oxide-based molecularly imprinted organically modified silica. In this study, we investigated the effect of different parameters (time, pH, and temperature) on the efficacy of the sorbent using response surface methodology (central composite design). The sorbent exhibited high binding capacities of 42 mg g−1 and 27 mg g−1 for deltamethrin and emamectin benzoate, respectively. Percentage recoveries were 93.3% and 94.2% for deltamethrin and emamectin benzoate, respectively. The selective detection of deltamethrin and emamectin benzoate from agricultural runoff was confirmed by real-sample analysis using high-performance liquid chromatography.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于氧化石墨烯的探针用于检测农业径流中的溴氰菊酯和苯甲酸戊酯杀虫剂
杀虫剂因其长期接触、持久性和生物累积性而对水生生态系统产生不利影响。溴氰菊酯和苯甲酸阿维菌素就是这两种杀虫剂,它们因在水果和蔬菜上的过度使用而进入水资源,对生物造成严重危害。在此,我们报告了一种用于从农业径流中选择性固相微萃取目标农药的探针的制造过程。该吸附剂是利用新型双模板氧化石墨烯基分子印迹有机改性二氧化硅设计的。研究采用响应面方法考察了不同参数(时间、pH 值和温度)对吸附剂功效的影响。该吸附剂对溴氰菊酯和苯甲酸阿维菌素的吸附容量分别为 42 mg g-1 和 27 mg g-1。苯甲酸阿维菌素的检出限和定量限分别为 0.31 和 0.59 µg L-1,溴氰菊酯的检出限和定量限分别为 0.41 和 0.92 µg L-1。吸附剂动力学研究表明,苯甲酸阿维菌素和溴氰菊酯的 χ2 值最低(分别为 0.72 和 1.69),R2 值最高(0.99),与假一阶模型相匹配。在研究吸附等温线时,发现 Freundlich 模型对两种模板的拟合效果最好。溴氰菊酯和苯甲酸阿维菌素的回收率分别为 93.3% 和 94.2%。通过使用高效液相色谱法进行实际样品分析,证实了从农业径流中选择性检测溴氰菊酯和苯甲酸阿维菌素的能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
7.20
自引率
4.30%
发文量
567
期刊最新文献
Hyperbaric oxygen treatment promotes tendon-bone interface healing in a rabbit model of rotator cuff tears. Oxygen-ozone therapy for myocardial ischemic stroke and cardiovascular disorders. Comparative study on the anti-inflammatory and protective effects of different oxygen therapy regimens on lipopolysaccharide-induced acute lung injury in mice. Heme oxygenase/carbon monoxide system and development of the heart. Hyperbaric oxygen for moderate-to-severe traumatic brain injury: outcomes 5-8 years after injury.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1