Effective low-cost pediatric vision screening by naive nonophthalmic examiners using the 'Arclight' device.

IF 2.1 4区 医学 Q2 OPHTHALMOLOGY Indian Journal of Ophthalmology Pub Date : 2025-01-01 Epub Date: 2024-07-11 DOI:10.4103/IJO.IJO_3027_23
Rujuta Gore, Jenny N Wang, Christopher D Yang, Miranda An, Stephen C Hunter, Kourosh Shahraki, Andrew Blaikie, Donny W Suh
{"title":"Effective low-cost pediatric vision screening by naive nonophthalmic examiners using the 'Arclight' device.","authors":"Rujuta Gore, Jenny N Wang, Christopher D Yang, Miranda An, Stephen C Hunter, Kourosh Shahraki, Andrew Blaikie, Donny W Suh","doi":"10.4103/IJO.IJO_3027_23","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To explore whether a low-cost ophthalmoscope (Arclight) can be used by naive nonophthalmic examiners to effectively screen for pediatric eye disease.</p><p><strong>Methods: </strong>Fifty-four children (108 eyes) were examined by five medical students using an Arclight. Gold standard examination was performed by an ophthalmologist using a slit lamp and indirect ophthalmoscope. Examinations performed included ophthalmoscopy of the optic disc, estimation of the cup-to-disc ratio (CDR), corneal light reflex test (CRT), Bruckner's reflex test (BRT), and evaluation of refractive error. We determined the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the nonophthalmologist's Arclight exam compared to the gold standard findings of comprehensive evaluation by pediatric ophthalmologists.</p><p><strong>Results: </strong>Using the Arclight, the optic nerve exam was successfully completed in 65% of patients. CDRs above and below 0.5 could be determined with 66.7% sensitivity and 84.4% specificity. Arclight CRT measurements were significant ( P < .00001) predictors of strabismus, with 80% sensitivity, 95.1%, specificity, 80% PPV, and 95.1% NPV. BRT was not a significant predictor of amblyopia, with a 34.6% sensitivity, 85.7% specificity, 69.2% PPV, and 58.5% NPV. Refractive error was estimated with a success rate of 81% for emmetropia, 38% for myopia, and 21% for hyperopia. The Arclight ease-of-use was rated on average as 4.4 (SD = 0.9) on a scale of 1 to 5, with 1 being the hardest and 5 being the easiest.</p><p><strong>Conclusions: </strong>Our study shows the Arclight as an affordable and effective alternative to the traditional ophthalmoscope for assessing eye disease in children. This device can improve eye health services in under-resourced regions.</p>","PeriodicalId":13329,"journal":{"name":"Indian Journal of Ophthalmology","volume":" ","pages":"41-44"},"PeriodicalIF":2.1000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4103/IJO.IJO_3027_23","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/11 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To explore whether a low-cost ophthalmoscope (Arclight) can be used by naive nonophthalmic examiners to effectively screen for pediatric eye disease.

Methods: Fifty-four children (108 eyes) were examined by five medical students using an Arclight. Gold standard examination was performed by an ophthalmologist using a slit lamp and indirect ophthalmoscope. Examinations performed included ophthalmoscopy of the optic disc, estimation of the cup-to-disc ratio (CDR), corneal light reflex test (CRT), Bruckner's reflex test (BRT), and evaluation of refractive error. We determined the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the nonophthalmologist's Arclight exam compared to the gold standard findings of comprehensive evaluation by pediatric ophthalmologists.

Results: Using the Arclight, the optic nerve exam was successfully completed in 65% of patients. CDRs above and below 0.5 could be determined with 66.7% sensitivity and 84.4% specificity. Arclight CRT measurements were significant ( P < .00001) predictors of strabismus, with 80% sensitivity, 95.1%, specificity, 80% PPV, and 95.1% NPV. BRT was not a significant predictor of amblyopia, with a 34.6% sensitivity, 85.7% specificity, 69.2% PPV, and 58.5% NPV. Refractive error was estimated with a success rate of 81% for emmetropia, 38% for myopia, and 21% for hyperopia. The Arclight ease-of-use was rated on average as 4.4 (SD = 0.9) on a scale of 1 to 5, with 1 being the hardest and 5 being the easiest.

Conclusions: Our study shows the Arclight as an affordable and effective alternative to the traditional ophthalmoscope for assessing eye disease in children. This device can improve eye health services in under-resourced regions.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
天真的非眼科检查员使用 "Arclight "设备进行有效的低成本儿童视力筛查。
目的:探讨低成本的眼科视力镜(Arclight)能否被非眼科专业的初学者用来有效筛查小儿眼病:方法: 五名医科学生使用 Arclight 检查了 54 名儿童(108 只眼睛)。金标准检查由眼科医生使用裂隙灯和间接检眼镜进行。检查项目包括视盘眼底镜检查、杯盘比(CDR)估算、角膜光反射测试(CRT)、布鲁克纳反射测试(BRT)和屈光不正评估。我们确定了非眼科医生的 Arclight 检查与儿科眼科医生综合评估的金标准结果相比的敏感性、特异性、阳性预测值 (PPV) 和阴性预测值 (NPV):使用 Arclight,65% 的患者成功完成了视神经检查。CDR高于或低于0.5的灵敏度为66.7%,特异度为84.4%。Arclight CRT 测量对斜视有显著的预测作用(P < .00001),灵敏度为 80%,特异性为 95.1%,PPV 为 80%,NPV 为 95.1%。BRT 对弱视的预测作用不明显,灵敏度为 34.6%,特异性为 85.7%,PPV 为 69.2%,NPV 为 58.5%。屈光不正的估计成功率为:散光 81%,近视 38%,远视 21%。Arclight的易用性平均为4.4(SD = 0.9)(1-5分),其中1分最难,5分最容易:我们的研究表明,Arclight 是替代传统眼底镜评估儿童眼疾的一种经济有效的方法。该设备可改善资源匮乏地区的眼健康服务。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.80
自引率
19.40%
发文量
1963
审稿时长
38 weeks
期刊介绍: Indian Journal of Ophthalmology covers clinical, experimental, basic science research and translational research studies related to medical, ethical and social issues in field of ophthalmology and vision science. Articles with clinical interest and implications will be given preference.
期刊最新文献
Clinical profile and outcomes of rejection after deep anterior lamellar keratoplasty in keratoconus. Effective low-cost pediatric vision screening by naive nonophthalmic examiners using the 'Arclight' device. Efficacy of dexamethasone implant in the management of chronic central serous chorioretinopathy without choroidal neovascularization. The Glowport - Illuminated vitrectomy trocar cannulas. Efficacy, safety, and tolerability of lifitegrast 5% eye drops: A randomized, double-blind, active-controlled trial in Indian patients with dry eye disease.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1