{"title":"Outcome of CAS under flow reversal and analysis for the intraprocedural flow of internal carotid artery","authors":"Daizo Ishii , Takeshi Hara , Masashi Kuwabara , Hiroshi Kondo , Shinji Kume , Nobutaka Horie","doi":"10.1016/j.clineuro.2024.108443","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><p>Carotid artery stenting (CAS) under flow reversal with dual protection using a proximal balloon and distal filter has been an established procedure for internal carotid artery (ICA) stenosis. This study investigates the effect of external carotid artery (ECA) occlusion on outcomes of CAS and ICA flow under flow reversal.</p></div><div><h3>Methods</h3><p>We reviewed 231 cases of CAS under flow reversal with ECA occlusion and 32 without. In the last 14 of 32 cases, the flow in the ICA under flow reversal was analyzed by ultrasound. The collateral index, which was defined as the total value of the maximum diameters of the ipsilateral anterior cerebral artery at the A1 segment and the anterior communicating artery, as well as those of the ipsilateral posterior cerebral artery at the P1 segment and the ipsilateral posterior communicating artery, and the maximum diameter of the ipsilateral ECA were correlated with the flow direction in the ICA.</p></div><div><h3>Results</h3><p>There was no significant difference in the outcome of CAS between the groups with or without ECA occlusion. Among the 14 cases without ECA occlusion, antegrade flow in the ICA was observed in 6 cases (42.9 %). The group with the antegrade flow in the ICA exhibited a significantly lower collateral index (5.08±0.33 vs 6.71±0.28, <em>p</em>=0.01) and a significantly larger ECA diameter (4.66±0.51 mm vs 3.21±1.24 mm, <em>p</em>=0.01) than the group with the stagnant or retrograde flow in the ICA.</p></div><div><h3>Conclusions</h3><p>The outcomes of CAS under flow reversal were acceptable even without ECA occlusion. The ECA occlusion may not be necessary for CAS under dual protection; however, distal filter protection should be used even under flow reversal.</p></div>","PeriodicalId":10385,"journal":{"name":"Clinical Neurology and Neurosurgery","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2024-07-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Neurology and Neurosurgery","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0303846724003305","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Objective
Carotid artery stenting (CAS) under flow reversal with dual protection using a proximal balloon and distal filter has been an established procedure for internal carotid artery (ICA) stenosis. This study investigates the effect of external carotid artery (ECA) occlusion on outcomes of CAS and ICA flow under flow reversal.
Methods
We reviewed 231 cases of CAS under flow reversal with ECA occlusion and 32 without. In the last 14 of 32 cases, the flow in the ICA under flow reversal was analyzed by ultrasound. The collateral index, which was defined as the total value of the maximum diameters of the ipsilateral anterior cerebral artery at the A1 segment and the anterior communicating artery, as well as those of the ipsilateral posterior cerebral artery at the P1 segment and the ipsilateral posterior communicating artery, and the maximum diameter of the ipsilateral ECA were correlated with the flow direction in the ICA.
Results
There was no significant difference in the outcome of CAS between the groups with or without ECA occlusion. Among the 14 cases without ECA occlusion, antegrade flow in the ICA was observed in 6 cases (42.9 %). The group with the antegrade flow in the ICA exhibited a significantly lower collateral index (5.08±0.33 vs 6.71±0.28, p=0.01) and a significantly larger ECA diameter (4.66±0.51 mm vs 3.21±1.24 mm, p=0.01) than the group with the stagnant or retrograde flow in the ICA.
Conclusions
The outcomes of CAS under flow reversal were acceptable even without ECA occlusion. The ECA occlusion may not be necessary for CAS under dual protection; however, distal filter protection should be used even under flow reversal.