Optofluidic photonic crystal fiber platform for sensitive and reliable fluorescence based biosensing.

IF 2.9 2区 医学 Q2 BIOCHEMICAL RESEARCH METHODS Biomedical optics express Pub Date : 2024-06-13 eCollection Date: 2024-07-01 DOI:10.1364/BOE.527248
Baptiste Moeglen-Paget, Jayakumar Perumal, Georges Humbert, Malini Olivo, U S Dinish
{"title":"Optofluidic photonic crystal fiber platform for sensitive and reliable fluorescence based biosensing.","authors":"Baptiste Moeglen-Paget, Jayakumar Perumal, Georges Humbert, Malini Olivo, U S Dinish","doi":"10.1364/BOE.527248","DOIUrl":null,"url":null,"abstract":"<p><p>Biosensing plays a pivotal role in various scientific domains, offering significant contributions to medical diagnostics, environmental monitoring, and biotechnology. Fluorescence biosensing relies on the fluorescence emission from labelled biomolecules to enable sensitive and selective identification and quantification of specific biological targets in various samples. Photonic crystal fibers (PCFs) have led to the development of optofluidic fibers enabling efficient light-liquid interaction within small liquid volume. Herein, we present the development of a user-friendly optofluidic-fiber platform with simple hardware requirements for sensitive and reliable fluorescence biosensing with high measurement repeatability. We demonstrate a sensitivity improvement of the fluorescence emission up to 17 times compared to standard cuvette measurement, with a limit of detection of Cy5 fluorophore as low as 100 pM. The improvement in measurement repeatability is exploited for detecting haptoglobin protein, a relevant biomarker to diagnose several diseases, by using commercially available Cy5 labelled antibodies. The study aims to showcase an optofluidic platform leveraging the benefits provided by optofluidic fibers, which encompass easy light injection, robustness, and high sensitivity.</p>","PeriodicalId":8969,"journal":{"name":"Biomedical optics express","volume":null,"pages":null},"PeriodicalIF":2.9000,"publicationDate":"2024-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11249680/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical optics express","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1364/BOE.527248","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

Biosensing plays a pivotal role in various scientific domains, offering significant contributions to medical diagnostics, environmental monitoring, and biotechnology. Fluorescence biosensing relies on the fluorescence emission from labelled biomolecules to enable sensitive and selective identification and quantification of specific biological targets in various samples. Photonic crystal fibers (PCFs) have led to the development of optofluidic fibers enabling efficient light-liquid interaction within small liquid volume. Herein, we present the development of a user-friendly optofluidic-fiber platform with simple hardware requirements for sensitive and reliable fluorescence biosensing with high measurement repeatability. We demonstrate a sensitivity improvement of the fluorescence emission up to 17 times compared to standard cuvette measurement, with a limit of detection of Cy5 fluorophore as low as 100 pM. The improvement in measurement repeatability is exploited for detecting haptoglobin protein, a relevant biomarker to diagnose several diseases, by using commercially available Cy5 labelled antibodies. The study aims to showcase an optofluidic platform leveraging the benefits provided by optofluidic fibers, which encompass easy light injection, robustness, and high sensitivity.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于灵敏可靠的荧光生物传感的光流体光子晶体光纤平台。
生物传感在各个科学领域发挥着举足轻重的作用,为医疗诊断、环境监测和生物技术做出了重大贡献。荧光生物传感依靠标记生物分子的荧光发射,实现对各种样品中特定生物目标的灵敏、选择性识别和定量。光子晶体纤维(PCFs)的开发推动了光流体纤维的发展,使其能够在小体积液体中实现高效的光-液相互作用。在本文中,我们介绍了一种用户友好型光导流体光纤平台的开发情况,该平台硬件要求简单,可用于灵敏可靠的荧光生物传感,测量重复性高。我们展示了与标准比色皿测量相比,荧光发射的灵敏度提高了 17 倍,Cy5 荧光团的检测限低至 100 pM。测量可重复性的提高被用于使用市售的 Cy5 标记抗体检测血红蛋白,血红蛋白是诊断多种疾病的相关生物标志物。这项研究旨在展示一种光流体平台,它充分利用了光流体纤维的优点,包括光注入方便、坚固耐用和灵敏度高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Biomedical optics express
Biomedical optics express BIOCHEMICAL RESEARCH METHODS-OPTICS
CiteScore
6.80
自引率
11.80%
发文量
633
审稿时长
1 months
期刊介绍: The journal''s scope encompasses fundamental research, technology development, biomedical studies and clinical applications. BOEx focuses on the leading edge topics in the field, including: Tissue optics and spectroscopy Novel microscopies Optical coherence tomography Diffuse and fluorescence tomography Photoacoustic and multimodal imaging Molecular imaging and therapies Nanophotonic biosensing Optical biophysics/photobiology Microfluidic optical devices Vision research.
期刊最新文献
Through-focus performance and off-axis effects in aspheric monofocal intraocular lenses Development of the international standard for functional near-infrared spectroscopy as a medical equipment A naturalistic approach to investigate the neural correlates of a laundry cycle with and without fragrance Microscope Integrated MHz Optical Coherence Tomography System for Neurosurgery: Development and Clinical In-Vivo Imaging Optical directional differential operation enabled visual chirality detection
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1