“SEMS-in-SEMS” technique for the removal of embedded fully covered self-expandable metal stents in benign pancreatic duct stricture

IF 5 2区 医学 Q1 GASTROENTEROLOGY & HEPATOLOGY Digestive Endoscopy Pub Date : 2024-07-17 DOI:10.1111/den.14887
Il Sang Shin, Jong Ho Moon, Yun Nah Lee
{"title":"“SEMS-in-SEMS” technique for the removal of embedded fully covered self-expandable metal stents in benign pancreatic duct stricture","authors":"Il Sang Shin,&nbsp;Jong Ho Moon,&nbsp;Yun Nah Lee","doi":"10.1111/den.14887","DOIUrl":null,"url":null,"abstract":"<p>Fully covered self-expandable metal stents (SEMS) are an alternative treatment option for persistent benign main pancreatic duct stricture (BPS), but their removal can be hampered by fibrosis formation and tissue overgrowth if the indwelling duration exceeds 3 months.<span><sup>1</sup></span> We present a case in which a fully covered SEMS, which initially could not be removed from the pancreatic duct, was retrieved using a “SEMS-in-SEMS” technique.</p><p>A 69-year-old male patient with a history of symptomatic chronic pancreatitis treated by multiple exchanges of plastic stents presented with abdominal pain. Computed tomography identified refractory BPS at the pancreatic head, and a fully covered SEMS (Bonastent M-intraductal; Standard Sci Tech, Seoul, South Korea) with a diameter of 8 mm and a length of 5 cm was inserted across the stricture. Although stent removal and a follow-up pancreatogram were scheduled at 3 months, the patient arbitrarily delayed visiting the hospital until 7 months after SEMS insertion. During the delayed follow-up endoscopic retrograde cholangiopancreatography, the inserted SEMS could not be removed, likely because it had become embedded in the pancreatic duct wall. Subsequent pancreatogram suggested tissue hyperplasia and overgrowth into the stent. The SEMS-in-SEMS technique was performed by placing a second fully covered SEMS with a diameter of 10 mm and a length of 7 cm, extended by 1 cm at both ends, inside the existing SEMS to compress the hyperplastic tissue and induce its ischemia and necrosis (Fig. 1, Video S1). One month later, an attempt to remove both stents using a rat-tooth forceps succeeded (Fig. 2).</p><p>The placement of a SEMS inside another SEMS can induce pressure necrosis of bile duct hyperplasia, enabling subsequent removal of the embedded biliary stent.<span><sup>2-4</sup></span> The SEMS-in-SEMS technique, which was documented only in the bile duct interventions, can also be safe and effective for the extraction of embedded SEMS in patients with BPS.</p><p>Authors declare no conflict of interest for this article.</p><p>This work was partly supported by the SoonChunHyang University Research Fund.</p>","PeriodicalId":159,"journal":{"name":"Digestive Endoscopy","volume":"36 10","pages":"1171-1172"},"PeriodicalIF":5.0000,"publicationDate":"2024-07-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/den.14887","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digestive Endoscopy","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/den.14887","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Fully covered self-expandable metal stents (SEMS) are an alternative treatment option for persistent benign main pancreatic duct stricture (BPS), but their removal can be hampered by fibrosis formation and tissue overgrowth if the indwelling duration exceeds 3 months.1 We present a case in which a fully covered SEMS, which initially could not be removed from the pancreatic duct, was retrieved using a “SEMS-in-SEMS” technique.

A 69-year-old male patient with a history of symptomatic chronic pancreatitis treated by multiple exchanges of plastic stents presented with abdominal pain. Computed tomography identified refractory BPS at the pancreatic head, and a fully covered SEMS (Bonastent M-intraductal; Standard Sci Tech, Seoul, South Korea) with a diameter of 8 mm and a length of 5 cm was inserted across the stricture. Although stent removal and a follow-up pancreatogram were scheduled at 3 months, the patient arbitrarily delayed visiting the hospital until 7 months after SEMS insertion. During the delayed follow-up endoscopic retrograde cholangiopancreatography, the inserted SEMS could not be removed, likely because it had become embedded in the pancreatic duct wall. Subsequent pancreatogram suggested tissue hyperplasia and overgrowth into the stent. The SEMS-in-SEMS technique was performed by placing a second fully covered SEMS with a diameter of 10 mm and a length of 7 cm, extended by 1 cm at both ends, inside the existing SEMS to compress the hyperplastic tissue and induce its ischemia and necrosis (Fig. 1, Video S1). One month later, an attempt to remove both stents using a rat-tooth forceps succeeded (Fig. 2).

The placement of a SEMS inside another SEMS can induce pressure necrosis of bile duct hyperplasia, enabling subsequent removal of the embedded biliary stent.2-4 The SEMS-in-SEMS technique, which was documented only in the bile duct interventions, can also be safe and effective for the extraction of embedded SEMS in patients with BPS.

Authors declare no conflict of interest for this article.

This work was partly supported by the SoonChunHyang University Research Fund.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在良性胰管狭窄中移除嵌入式全覆盖自膨胀金属支架的 "SEMS-in-SEMS "技术。
全覆盖自膨胀金属支架(SEMS)是治疗顽固性良性主胰管狭窄(BPS)的一种替代疗法,但如果留置时间超过3个月,纤维化的形成和组织过度生长会阻碍支架的取出。我们介绍了一例利用 "SEMS-in-SEMS "技术从胰管中取出最初无法取出的全覆盖 SEMS 的病例。一名 69 岁的男性患者因腹痛前来就诊,该患者曾有症状性慢性胰腺炎病史,曾多次更换塑料支架治疗。计算机断层扫描发现胰头处有难治性 BPS,于是将直径 8 毫米、长 5 厘米的全覆盖 SEMS(Bonastent M-intraductal;Standard Sci Tech,韩国首尔)插入狭窄处。虽然计划在 3 个月后取出支架并进行胰腺造影随访,但患者却擅自推迟到 SEMS 植入 7 个月后才到医院就诊。在延迟的内镜逆行胰胆管造影随访中,插入的 SEMS 无法取出,很可能是因为它已经嵌入了胰管壁。随后的胰腺造影显示,支架内有组织增生和过度生长。我们采用了SEMS-in-SEMS技术,将第二个直径为10毫米、长度为7厘米、两端延长1厘米的全覆盖SEMS放置在现有的SEMS内,以压迫增生组织并诱导其缺血和坏死(图1,视频S1)。一个月后,使用鼠齿钳成功取出了两个支架(图 2)。将 SEMS 置于另一个 SEMS 内可诱导胆管增生组织受压坏死,从而随后取出嵌入的胆道支架。2-4 SEMS-in-SEMS技术仅在胆管介入治疗中有所记载,但也可安全有效地取出BPS患者体内的嵌入式SEMS。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Digestive Endoscopy
Digestive Endoscopy 医学-外科
CiteScore
10.10
自引率
15.10%
发文量
291
审稿时长
6-12 weeks
期刊介绍: Digestive Endoscopy (DEN) is the official journal of the Japan Gastroenterological Endoscopy Society, the Asian Pacific Society for Digestive Endoscopy and the World Endoscopy Organization. Digestive Endoscopy serves as a medium for presenting original articles that offer significant contributions to knowledge in the broad field of endoscopy. The Journal also includes Reviews, Original Articles, How I Do It, Case Reports (only of exceptional interest and novelty are accepted), Letters, Techniques and Images, abstracts and news items that may be of interest to endoscopists.
期刊最新文献
Cover Image Issue Information WEO Newsletter: Evaluation and Endoscopic Management of Disconnected Pancreatic Duct Syndrome New milestone for clinical research about biliary drainage Issue Information
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1