A study on beneficial impact of the use of medium-molecular-weight hydroxyethyl starch in granulocyte apheresis using continuous-flow cell separator Spectra Optia: A retrospective single-center study at a tertiary care oncology center.

IF 0.6 Q4 HEMATOLOGY Asian Journal of Transfusion Science Pub Date : 2024-01-01 Epub Date: 2023-11-07 DOI:10.4103/ajts.ajts_43_23
Amardeep Pathak, Devasis Panda, Narender Tejwani, Anurag Mehta
{"title":"A study on beneficial impact of the use of medium-molecular-weight hydroxyethyl starch in granulocyte apheresis using continuous-flow cell separator Spectra Optia: A retrospective single-center study at a tertiary care oncology center.","authors":"Amardeep Pathak, Devasis Panda, Narender Tejwani, Anurag Mehta","doi":"10.4103/ajts.ajts_43_23","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Granulocyte transfusion is one of the best therapeutic modalities in prolonged neutropenic patients with severe bacterial/fungal infections. Granulocyte harvest using conventional acid citrate dextrose (ACD) anticoagulant (ACD-A) by apheresis is not satisfactory in comparison to the use of hydroxyethyl starch (HES), but the latter is associated with various adverse events, especially with high-molecular-weight HES.</p><p><strong>Aims and objective: </strong>This study aimed to assess the beneficial impact of the use of medium-molecular-weight (MMW)-HES and trisodium citrate combination over ACD-A in granulocyte apheresis when using Spectra Optia.</p><p><strong>Materials and methods: </strong>This was a retrospective study comparing granulocyte harvest results with the use of ACD or HES and trisodium citrate combination. All the donors in both the groups received single 600 μg of granulocyte colony-stimulating factor subcutaneous injection followed by 8 mg of dexamethasone tablet 10-12 h and omnacortil 60 mg orally 3 h before harvest. A number of adverse incidents, if any, were observed and noted. Donor/procedure parameters were compared using Mann-Whitney <i>U</i>-test/unpaired <i>t</i>-test.</p><p><strong>Results: </strong>Granulocyte yield (mean: 3.29 × 10<sup>10</sup>/unit vs. 4.5 × 10<sup>10</sup>/unit in the ACD and HES groups, respectively, <i>P</i> ≤ 0.0001) was significantly better in the HES group. The collection efficiency was also better in the HES group (mean: 15.86% vs. 26.70% in the ACD and HES groups, respectively, <i>P</i> ≤ 0.0001) in the ACD and HES groups, respectively. There was no significant adverse event noted in any of these two groups.</p><p><strong>Conclusion: </strong>In our study, granulocytes with optimum yield can be easily harvested with Spectra Optia cell separator using 6% HES (MMW) and trisodium citrate combination with standard 12-h interval gap between mobilization and harvest. This strategy can also have no or minimal extra cost burden to patients.</p>","PeriodicalId":42296,"journal":{"name":"Asian Journal of Transfusion Science","volume":"18 1","pages":"79-84"},"PeriodicalIF":0.6000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11259344/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Transfusion Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/ajts.ajts_43_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/7 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Granulocyte transfusion is one of the best therapeutic modalities in prolonged neutropenic patients with severe bacterial/fungal infections. Granulocyte harvest using conventional acid citrate dextrose (ACD) anticoagulant (ACD-A) by apheresis is not satisfactory in comparison to the use of hydroxyethyl starch (HES), but the latter is associated with various adverse events, especially with high-molecular-weight HES.

Aims and objective: This study aimed to assess the beneficial impact of the use of medium-molecular-weight (MMW)-HES and trisodium citrate combination over ACD-A in granulocyte apheresis when using Spectra Optia.

Materials and methods: This was a retrospective study comparing granulocyte harvest results with the use of ACD or HES and trisodium citrate combination. All the donors in both the groups received single 600 μg of granulocyte colony-stimulating factor subcutaneous injection followed by 8 mg of dexamethasone tablet 10-12 h and omnacortil 60 mg orally 3 h before harvest. A number of adverse incidents, if any, were observed and noted. Donor/procedure parameters were compared using Mann-Whitney U-test/unpaired t-test.

Results: Granulocyte yield (mean: 3.29 × 1010/unit vs. 4.5 × 1010/unit in the ACD and HES groups, respectively, P ≤ 0.0001) was significantly better in the HES group. The collection efficiency was also better in the HES group (mean: 15.86% vs. 26.70% in the ACD and HES groups, respectively, P ≤ 0.0001) in the ACD and HES groups, respectively. There was no significant adverse event noted in any of these two groups.

Conclusion: In our study, granulocytes with optimum yield can be easily harvested with Spectra Optia cell separator using 6% HES (MMW) and trisodium citrate combination with standard 12-h interval gap between mobilization and harvest. This strategy can also have no or minimal extra cost burden to patients.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用连续流细胞分离器 Spectra Optia 在粒细胞分离过程中使用中分子量羟乙基淀粉的有益影响研究:在一家三级肿瘤中心进行的单中心回顾性研究。
简介对于患有严重细菌/真菌感染的长期中性粒细胞病患者来说,粒细胞输注是最好的治疗方式之一。与使用羟乙基淀粉(HES)相比,使用常规酸性枸橼酸葡萄糖(ACD)抗凝剂(ACD-A)通过无细胞疗法采集粒细胞的效果并不理想,但后者与各种不良事件有关,尤其是高分子量的羟乙基淀粉:本研究旨在评估在使用 Spectra Optia 进行粒细胞无细胞采集时,中分子量(MMW)-HES 和枸橼酸三钠的联合使用对 ACD-A 的有益影响:这是一项回顾性研究,比较了使用 ACD 或 HES 和枸橼酸三钠组合的粒细胞采集结果。两组的所有捐献者在采集前 10-12 小时均接受了单次 600 μg 粒细胞集落刺激因子皮下注射,随后服用 8 mg 地塞米松片剂,并在采集前 3 小时口服 60 mg 奥那可的松。观察并记录了一些不良事件(如有)。使用 Mann-Whitney U 检验/非配对 t 检验比较供体/程序参数:结果:粒细胞产量(平均结果:粒细胞产量(平均值:3.29 × 1010/单位,ACD 组和 HES 组分别为 4.5 × 1010/单位,P≤0.0001)明显高于 HES 组。ACD 组和 HES 组的收集效率也分别高于 HES 组(ACD 组和 HES 组的收集效率分别为 15.86% 和 26.70%,P≤ 0.0001)。两组均未发现明显的不良反应:在我们的研究中,使用 Spectra Optia 细胞分离器,结合 6% HES (MMW) 和枸橼酸三钠,在动员和收获之间间隔 12 小时的标准时间内,可以轻松收获产量最佳的粒细胞。这种策略也不会给患者带来额外的费用负担,或者说负担极小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
0.90
自引率
0.00%
发文量
56
审稿时长
44 weeks
期刊最新文献
A method for selecting P antigen-negative red cell units for patients with paroxysmal cold hemoglobinuria. A review of issues and challenges of implementation of patient blood management. A study on beneficial impact of the use of medium-molecular-weight hydroxyethyl starch in granulocyte apheresis using continuous-flow cell separator Spectra Optia: A retrospective single-center study at a tertiary care oncology center. Aweak phenotype associated with novel ABO*A allele variant c.106delinsGG. Antioxidative effects of α-tocopherol on stored human red blood cell units.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1