{"title":"Efficacy and safety of a self-expandable retainer in endoscopic ear surgery.","authors":"Yun Ji Lee, Woo Seok Kang, Jong Woo Chung","doi":"10.1007/s00405-024-08838-z","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>During endoscopic ear surgery (EES), it is important to maintain a clear view of the endoscopic camera to achieve a clean field. In this study, a self-expandable external auditory canal (EAC) retainer was developed to enable a more efficient and safer EES. This study aimed to evaluate the retainer's efficacy and safety in EES.</p><p><strong>Methods: </strong>Among adult patients scheduled for endoscopic tympanoplasty, 50 participants were recruited. They were assigned to either the retainer or control group in a 1:1 ratio. The anatomical characteristics, number of endoscopic cleanings during surgery, surgeon's satisfaction, and other factors were evaluated.</p><p><strong>Results: </strong>No differences were observed in the surgical direction, EAC size measured on preoperative temporal bone computed tomography scans, location and size of tympanic membrane perforation, or bleeding degree between the two groups. When comparing the surgical time, including retainer insertion and removal, the time was similar between groups (retainer group, 35 min; control group, 33.2 min). The frequency of endoscopic cleaning per minute was statistically significantly lower in the retainer group than in the control group (0.18 times per minute, p = 0.048). No side effects, including sensory abnormalities or allergic reactions, were reported in any patient who used the retainer.</p><p><strong>Conclusion: </strong>A reduction in unnecessary endoscopic cleaning during EES was observed while using the self-expandable retainer, leading to increased surgeon satisfaction and efficiency. Furthermore, as a safe method without side effects, the retainer could be widely used to various indications for EES beyond tympanoplasty.</p>","PeriodicalId":11952,"journal":{"name":"European Archives of Oto-Rhino-Laryngology","volume":" ","pages":"6267-6273"},"PeriodicalIF":1.9000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Archives of Oto-Rhino-Laryngology","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1007/s00405-024-08838-z","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/24 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: During endoscopic ear surgery (EES), it is important to maintain a clear view of the endoscopic camera to achieve a clean field. In this study, a self-expandable external auditory canal (EAC) retainer was developed to enable a more efficient and safer EES. This study aimed to evaluate the retainer's efficacy and safety in EES.
Methods: Among adult patients scheduled for endoscopic tympanoplasty, 50 participants were recruited. They were assigned to either the retainer or control group in a 1:1 ratio. The anatomical characteristics, number of endoscopic cleanings during surgery, surgeon's satisfaction, and other factors were evaluated.
Results: No differences were observed in the surgical direction, EAC size measured on preoperative temporal bone computed tomography scans, location and size of tympanic membrane perforation, or bleeding degree between the two groups. When comparing the surgical time, including retainer insertion and removal, the time was similar between groups (retainer group, 35 min; control group, 33.2 min). The frequency of endoscopic cleaning per minute was statistically significantly lower in the retainer group than in the control group (0.18 times per minute, p = 0.048). No side effects, including sensory abnormalities or allergic reactions, were reported in any patient who used the retainer.
Conclusion: A reduction in unnecessary endoscopic cleaning during EES was observed while using the self-expandable retainer, leading to increased surgeon satisfaction and efficiency. Furthermore, as a safe method without side effects, the retainer could be widely used to various indications for EES beyond tympanoplasty.
期刊介绍:
Official Journal of
European Union of Medical Specialists – ORL Section and Board
Official Journal of Confederation of European Oto-Rhino-Laryngology Head and Neck Surgery
"European Archives of Oto-Rhino-Laryngology" publishes original clinical reports and clinically relevant experimental studies, as well as short communications presenting new results of special interest. With peer review by a respected international editorial board and prompt English-language publication, the journal provides rapid dissemination of information by authors from around the world. This particular feature makes it the journal of choice for readers who want to be informed about the continuing state of the art concerning basic sciences and the diagnosis and management of diseases of the head and neck on an international level.
European Archives of Oto-Rhino-Laryngology was founded in 1864 as "Archiv für Ohrenheilkunde" by A. von Tröltsch, A. Politzer and H. Schwartze.