Oxidation of Ni–30Cr Alloy at Low Temperature and Low Oxygen Partial Pressure: Experimental Methods to Improve Kinetics Constants Determination

IF 2.1 3区 材料科学 Q2 METALLURGY & METALLURGICAL ENGINEERING Oxidation of Metals Pub Date : 2024-07-26 DOI:10.1007/s11085-024-10270-x
S. Bosonnet, X. Huang, L. Bataillou, L. Martinelli, Paul C. M. Fossati, Laurence Latu-Romain, Yves Wouters, C. Desgranges, D. Monceau
{"title":"Oxidation of Ni–30Cr Alloy at Low Temperature and Low Oxygen Partial Pressure: Experimental Methods to Improve Kinetics Constants Determination","authors":"S. Bosonnet,&nbsp;X. Huang,&nbsp;L. Bataillou,&nbsp;L. Martinelli,&nbsp;Paul C. M. Fossati,&nbsp;Laurence Latu-Romain,&nbsp;Yves Wouters,&nbsp;C. Desgranges,&nbsp;D. Monceau","doi":"10.1007/s11085-024-10270-x","DOIUrl":null,"url":null,"abstract":"<div><p>Ni–30Cr model alloy was used to study chromia-scale formation behaviour. During its formation the mass variation signal is weak and it is important to take specific care to measure oxidation kinetics by thermogravimetric analysis. Symmetrical design allows the determination of very small mass changes in compensating buoyancy effects and limiting measurement drift. The mass variation measurement comprises noise coming from different sources that affects the electronic signal. It must be minimised to improve accuracy. This involves keeping the room-temperature constant, strictly balancing the beam and minimising buoyancy effects. By this way it was possible to acquire kinetics and to measured rate constants, <i>k</i><sub><i>p</i></sub>, in a range from 3.10<sup>–5</sup> to 3.10<sup>–10</sup> mg<sup>2</sup>.cm<sup>−4</sup>.s<sup>−1</sup> equivalent to 10<sup>–12</sup> down to 10<sup>–17</sup> cm<sup>2</sup>.s<sup>−1</sup>. Oxygen partial pressure (<span>\\({P}_{{O}_{2}}\\)</span>) was monitor and revealed an abnormal consumption of oxygen at the beginning of the thermal exposure. Experiments with an inert material showed parasitic reactions identified by mass spectrometry as combustion of impurities. As oxygen consumption is not only due to oxidation of the sample, corrosion kinetics can’t be deduced from it. Hence, to determine whether the oxygen supply from the gas is a limiting parameter, a model, which quantifies oxygen consumption by sample oxidation within the thermobalance, is proposed.</p></div>","PeriodicalId":724,"journal":{"name":"Oxidation of Metals","volume":"101 5","pages":"1197 - 1209"},"PeriodicalIF":2.1000,"publicationDate":"2024-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s11085-024-10270-x.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Oxidation of Metals","FirstCategoryId":"88","ListUrlMain":"https://link.springer.com/article/10.1007/s11085-024-10270-x","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"METALLURGY & METALLURGICAL ENGINEERING","Score":null,"Total":0}
引用次数: 0

Abstract

Ni–30Cr model alloy was used to study chromia-scale formation behaviour. During its formation the mass variation signal is weak and it is important to take specific care to measure oxidation kinetics by thermogravimetric analysis. Symmetrical design allows the determination of very small mass changes in compensating buoyancy effects and limiting measurement drift. The mass variation measurement comprises noise coming from different sources that affects the electronic signal. It must be minimised to improve accuracy. This involves keeping the room-temperature constant, strictly balancing the beam and minimising buoyancy effects. By this way it was possible to acquire kinetics and to measured rate constants, kp, in a range from 3.10–5 to 3.10–10 mg2.cm−4.s−1 equivalent to 10–12 down to 10–17 cm2.s−1. Oxygen partial pressure (\({P}_{{O}_{2}}\)) was monitor and revealed an abnormal consumption of oxygen at the beginning of the thermal exposure. Experiments with an inert material showed parasitic reactions identified by mass spectrometry as combustion of impurities. As oxygen consumption is not only due to oxidation of the sample, corrosion kinetics can’t be deduced from it. Hence, to determine whether the oxygen supply from the gas is a limiting parameter, a model, which quantifies oxygen consumption by sample oxidation within the thermobalance, is proposed.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Ni-30Cr 合金在低温和低氧分压下的氧化:改进动力学常数测定的实验方法
镍-30Cr 模型合金用于研究铬鳞的形成行为。在其形成过程中,质量变化信号很微弱,因此必须特别注意通过热重分析测量氧化动力学。通过对称设计,可以在补偿浮力效应和限制测量漂移的情况下测定极小的质量变化。质量变化测量包括来自不同来源的噪声,这些噪声会影响电子信号。必须尽量减少噪音,以提高精度。这包括保持室温恒定、严格平衡光束和尽量减少浮力效应。通过这种方法,可以获得动力学和测量速率常数 kp,范围从 3.10-5 到 3.10-10 mg2.cm-4.s-1 相当于 10-12 到 10-17 cm2.s-1。氧分压(\({P}_{O}_{2}}\))监测显示,在热暴露开始时氧气消耗异常。使用惰性材料进行的实验表明,通过质谱分析,寄生反应被确定为杂质燃烧。由于氧气消耗不仅仅是由于样品氧化造成的,因此无法从中推断出腐蚀动力学。因此,为了确定气体供氧是否是一个限制性参数,我们提出了一个模型,该模型量化了热平衡中样品氧化的耗氧量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Oxidation of Metals
Oxidation of Metals 工程技术-冶金工程
CiteScore
5.10
自引率
9.10%
发文量
47
审稿时长
2.2 months
期刊介绍: Oxidation of Metals is the premier source for the rapid dissemination of current research on all aspects of the science of gas-solid reactions at temperatures greater than about 400˚C, with primary focus on the high-temperature corrosion of bulk and coated systems. This authoritative bi-monthly publishes original scientific papers on kinetics, mechanisms, studies of scales from structural and morphological viewpoints, transport properties in scales, phase-boundary reactions, and much more. Articles may discuss both theoretical and experimental work related to gas-solid reactions at the surface or near-surface of a material exposed to elevated temperatures, including reactions with oxygen, nitrogen, sulfur, carbon and halogens. In addition, Oxidation of Metals publishes the results of frontier research concerned with deposit-induced attack. Review papers and short technical notes are encouraged.
期刊最新文献
Segmentation and Metallographic Evaluation of Aluminium Slurry Coatings Using Machine Learning Techniques Editorial on Modeling, Prediction and Simulation Editorial on Oxidation in Complex Atmospheres Editorial on Oxidation of Novel Metallic Materials (Intermetallics, MMCs, HEAs…) Editorial on Coatings
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1