Donát Szebeni , Roland Told , Sándor Kunsági-Máté , József Szalma , Péter Maróti , Katalin Böddi , Edina Lempel
{"title":"Monomer elution and shrinkage stress analysis of addition-fragmentation chain-transfer-modified resin composites in relation to the curing protocol","authors":"Donát Szebeni , Roland Told , Sándor Kunsági-Máté , József Szalma , Péter Maróti , Katalin Böddi , Edina Lempel","doi":"10.1016/j.dental.2024.07.029","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><p>The purpose was to compare the effects of rapid (3 s) and conventional (20 s) polymerization protocols (PP) of mono- and multichip LED curing units (LCU) on shrinkage stress (SS) and monomer elution (ME) in bulk-fill resin-based composites (RBC) with and without addition-fragmentation chain-transfer (AFCT) monomer.</p></div><div><h3>Methods</h3><p>Cylindrical (5x4mm) specimens were prepared from two RBCs containing different AFCT monomers (Filtek OneBulk-FOB; Tetric PowerFill-TPF) and one without (Tetric EvoCeram Bulk-TEC). After soaking for 3, 10, and 14 days (75 % ethanol), ME was quantified using standard monomers by High-Performance Liquid Chromatography. SS was measured from the start of polymerization to 5 min using a Materials Testing Machine. The radiant exitance of LCUs was measured using a spectrophotometer. ANOVA and Tukey's post-hoc test, multivariate analysis and partial eta-squared statistics were used to analyze the data (p < 0.05).</p></div><div><h3>Results</h3><p>AFCT-modification significantly decreased ME (p < 0.001). ME was reduced by half by day 10 and by one tenth by the end of the 14-day compared to the 3-day sampling. ME itself was dependent, whereas the percentage of monomers released was independent of the PP used (p > 0.05). FOB showed the lowest SS (p < 0.001), while there was no significant difference between TPF and TEC (p = 0.124). Both ME and SS were significantly influenced by material type and PP.</p></div><div><h3>Significance</h3><p>The incorporation of the AFCT monomer reduced ME, but this was inversely related to a decrease in exposure time. SS values reduced by rapid PP in parallel with increasing ME values. The utilization of the AFCT molecule in conjunction with an appropriate resin-, initiator-system is of significant consequence for the kinetics of polymerization and the incorporation of monomers into the network.</p></div>","PeriodicalId":298,"journal":{"name":"Dental Materials","volume":"40 10","pages":"Pages 1611-1623"},"PeriodicalIF":4.6000,"publicationDate":"2024-07-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0109564124002318/pdfft?md5=870100ad6e2008ffd2c6f0ebe43c0d75&pid=1-s2.0-S0109564124002318-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dental Materials","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0109564124002318","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Objective
The purpose was to compare the effects of rapid (3 s) and conventional (20 s) polymerization protocols (PP) of mono- and multichip LED curing units (LCU) on shrinkage stress (SS) and monomer elution (ME) in bulk-fill resin-based composites (RBC) with and without addition-fragmentation chain-transfer (AFCT) monomer.
Methods
Cylindrical (5x4mm) specimens were prepared from two RBCs containing different AFCT monomers (Filtek OneBulk-FOB; Tetric PowerFill-TPF) and one without (Tetric EvoCeram Bulk-TEC). After soaking for 3, 10, and 14 days (75 % ethanol), ME was quantified using standard monomers by High-Performance Liquid Chromatography. SS was measured from the start of polymerization to 5 min using a Materials Testing Machine. The radiant exitance of LCUs was measured using a spectrophotometer. ANOVA and Tukey's post-hoc test, multivariate analysis and partial eta-squared statistics were used to analyze the data (p < 0.05).
Results
AFCT-modification significantly decreased ME (p < 0.001). ME was reduced by half by day 10 and by one tenth by the end of the 14-day compared to the 3-day sampling. ME itself was dependent, whereas the percentage of monomers released was independent of the PP used (p > 0.05). FOB showed the lowest SS (p < 0.001), while there was no significant difference between TPF and TEC (p = 0.124). Both ME and SS were significantly influenced by material type and PP.
Significance
The incorporation of the AFCT monomer reduced ME, but this was inversely related to a decrease in exposure time. SS values reduced by rapid PP in parallel with increasing ME values. The utilization of the AFCT molecule in conjunction with an appropriate resin-, initiator-system is of significant consequence for the kinetics of polymerization and the incorporation of monomers into the network.
期刊介绍:
Dental Materials publishes original research, review articles, and short communications.
Academy of Dental Materials members click here to register for free access to Dental Materials online.
The principal aim of Dental Materials is to promote rapid communication of scientific information between academia, industry, and the dental practitioner. Original Manuscripts on clinical and laboratory research of basic and applied character which focus on the properties or performance of dental materials or the reaction of host tissues to materials are given priority publication. Other acceptable topics include application technology in clinical dentistry and dental laboratory technology.
Comprehensive reviews and editorial commentaries on pertinent subjects will be considered.