Monomer elution and shrinkage stress analysis of addition-fragmentation chain-transfer-modified resin composites in relation to the curing protocol

IF 4.6 1区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Dental Materials Pub Date : 2024-07-29 DOI:10.1016/j.dental.2024.07.029
Donát Szebeni , Roland Told , Sándor Kunsági-Máté , József Szalma , Péter Maróti , Katalin Böddi , Edina Lempel
{"title":"Monomer elution and shrinkage stress analysis of addition-fragmentation chain-transfer-modified resin composites in relation to the curing protocol","authors":"Donát Szebeni ,&nbsp;Roland Told ,&nbsp;Sándor Kunsági-Máté ,&nbsp;József Szalma ,&nbsp;Péter Maróti ,&nbsp;Katalin Böddi ,&nbsp;Edina Lempel","doi":"10.1016/j.dental.2024.07.029","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><p>The purpose was to compare the effects of rapid (3 s) and conventional (20 s) polymerization protocols (PP) of mono- and multichip LED curing units (LCU) on shrinkage stress (SS) and monomer elution (ME) in bulk-fill resin-based composites (RBC) with and without addition-fragmentation chain-transfer (AFCT) monomer.</p></div><div><h3>Methods</h3><p>Cylindrical (5x4mm) specimens were prepared from two RBCs containing different AFCT monomers (Filtek OneBulk-FOB; Tetric PowerFill-TPF) and one without (Tetric EvoCeram Bulk-TEC). After soaking for 3, 10, and 14 days (75 % ethanol), ME was quantified using standard monomers by High-Performance Liquid Chromatography. SS was measured from the start of polymerization to 5 min using a Materials Testing Machine. The radiant exitance of LCUs was measured using a spectrophotometer. ANOVA and Tukey's post-hoc test, multivariate analysis and partial eta-squared statistics were used to analyze the data (p &lt; 0.05).</p></div><div><h3>Results</h3><p>AFCT-modification significantly decreased ME (p &lt; 0.001). ME was reduced by half by day 10 and by one tenth by the end of the 14-day compared to the 3-day sampling. ME itself was dependent, whereas the percentage of monomers released was independent of the PP used (p &gt; 0.05). FOB showed the lowest SS (p &lt; 0.001), while there was no significant difference between TPF and TEC (p = 0.124). Both ME and SS were significantly influenced by material type and PP.</p></div><div><h3>Significance</h3><p>The incorporation of the AFCT monomer reduced ME, but this was inversely related to a decrease in exposure time. SS values reduced by rapid PP in parallel with increasing ME values. The utilization of the AFCT molecule in conjunction with an appropriate resin-, initiator-system is of significant consequence for the kinetics of polymerization and the incorporation of monomers into the network.</p></div>","PeriodicalId":298,"journal":{"name":"Dental Materials","volume":"40 10","pages":"Pages 1611-1623"},"PeriodicalIF":4.6000,"publicationDate":"2024-07-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0109564124002318/pdfft?md5=870100ad6e2008ffd2c6f0ebe43c0d75&pid=1-s2.0-S0109564124002318-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dental Materials","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0109564124002318","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objective

The purpose was to compare the effects of rapid (3 s) and conventional (20 s) polymerization protocols (PP) of mono- and multichip LED curing units (LCU) on shrinkage stress (SS) and monomer elution (ME) in bulk-fill resin-based composites (RBC) with and without addition-fragmentation chain-transfer (AFCT) monomer.

Methods

Cylindrical (5x4mm) specimens were prepared from two RBCs containing different AFCT monomers (Filtek OneBulk-FOB; Tetric PowerFill-TPF) and one without (Tetric EvoCeram Bulk-TEC). After soaking for 3, 10, and 14 days (75 % ethanol), ME was quantified using standard monomers by High-Performance Liquid Chromatography. SS was measured from the start of polymerization to 5 min using a Materials Testing Machine. The radiant exitance of LCUs was measured using a spectrophotometer. ANOVA and Tukey's post-hoc test, multivariate analysis and partial eta-squared statistics were used to analyze the data (p < 0.05).

Results

AFCT-modification significantly decreased ME (p < 0.001). ME was reduced by half by day 10 and by one tenth by the end of the 14-day compared to the 3-day sampling. ME itself was dependent, whereas the percentage of monomers released was independent of the PP used (p > 0.05). FOB showed the lowest SS (p < 0.001), while there was no significant difference between TPF and TEC (p = 0.124). Both ME and SS were significantly influenced by material type and PP.

Significance

The incorporation of the AFCT monomer reduced ME, but this was inversely related to a decrease in exposure time. SS values reduced by rapid PP in parallel with increasing ME values. The utilization of the AFCT molecule in conjunction with an appropriate resin-, initiator-system is of significant consequence for the kinetics of polymerization and the incorporation of monomers into the network.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
与固化方案有关的加成-断裂链转移改性树脂复合材料的单体洗脱和收缩应力分析。
研究目的目的是比较单片和多片 LED 固化单元(LCU)的快速(3 秒)和常规(20 秒)聚合方案(PP)对含和不含加成-断裂链转移(AFCT)单体的块状填充树脂基复合材料(RBC)的收缩应力(SS)和单体洗脱(ME)的影响:用两种含不同 AFCT 单体的 RBC(Filtek OneBulk-FOB;Tetric PowerFill-TPF)和一种不含 AFCT 单体的 RBC(Tetric EvoCeram Bulk-TEC)制备圆柱形(5x4 毫米)试样。浸泡 3 天、10 天和 14 天(75% 乙醇)后,使用标准单体通过高效液相色谱法对 ME 进行量化。使用材料试验机测量了从聚合开始到 5 分钟的 SS 值。使用分光光度计测量 LCU 的辐射出射率。采用方差分析、Tukey 后检验、多元分析和部分等方统计来分析数据(p 结果:AFCT 改性明显降低了 ME(p 0.05)。FOB 显示出最低的 SS(p 显著性:AFCT 单体的加入降低了 ME 值,但这与暴露时间的缩短成反比。随着 ME 值的增加,SS 值也随 PP 值的快速增加而降低。将 AFCT 分子与适当的树脂、引发剂系统结合使用,对聚合动力学和单体融入网络具有重要意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Dental Materials
Dental Materials 工程技术-材料科学:生物材料
CiteScore
9.80
自引率
10.00%
发文量
290
审稿时长
67 days
期刊介绍: Dental Materials publishes original research, review articles, and short communications. Academy of Dental Materials members click here to register for free access to Dental Materials online. The principal aim of Dental Materials is to promote rapid communication of scientific information between academia, industry, and the dental practitioner. Original Manuscripts on clinical and laboratory research of basic and applied character which focus on the properties or performance of dental materials or the reaction of host tissues to materials are given priority publication. Other acceptable topics include application technology in clinical dentistry and dental laboratory technology. Comprehensive reviews and editorial commentaries on pertinent subjects will be considered.
期刊最新文献
Bonding neat hydrophobic-rich resins to etched dentin: A proof of concept. Models for shrinkage stress: C-factor and all that. Ability of a novel primer to enhance the polymerization of a self-cured resin composite. Classification and bibliometric analysis of hydrogels in periodontitis treatment: Trends, mechanisms, advantages, and future research directions. Microspheres of stem cells from human exfoliated deciduous teeth exhibit superior pulp regeneration capacity.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1