Glycine-modified Pencil Graphite Electrode as a Sensor for Caffeine Determination: A Voltammetric Study

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY Accounts of Chemical Research Pub Date : 2024-07-30 DOI:10.2174/0115734110324545240725114425
Şeyma Korkmaz, Wael Bosnali, Hafizullah Sharifi, İbrahim Ender Mülazımoğlu, Ayşen Demir Mülazımoğlu
{"title":"Glycine-modified Pencil Graphite Electrode as a Sensor for Caffeine Determination: A Voltammetric Study","authors":"Şeyma Korkmaz, Wael Bosnali, Hafizullah Sharifi, İbrahim Ender Mülazımoğlu, Ayşen Demir Mülazımoğlu","doi":"10.2174/0115734110324545240725114425","DOIUrl":null,"url":null,"abstract":"Background: Caffeine (CAF) is a widely used chemical in foods and pharmaceuticals that is consumed by a lot of people every day. Overconsumption of caffeine can lead to some undesirable symptoms. However, CAF is considered a crucial nervous system stimulant. Aims: This study aimed to find an accurate and effective route for determining caffeine using voltammetric techniques. Objective: In this work, for the first time, a glycine (Gly) modified pencil graphite electrode (Gly/PGE) was used for the determination of caffeine (CAF) by Square Wave Adsorptive Stripping Voltammetry (SWAdSV) technique. Methods: The modification procedure of PGE by Gly was accomplished by performing the cyclic voltammetry (CV) technique for 10 cycles at a potential range of 0.8 to 1.8 V. Moreover, the characterization of Gly/PGE was done by applying the CV technique in aqueous and non-aqueous media and electrochemical impedance spectroscopy (EIS) in addition to the SEM technique. The movement type of CAF toward Gly/PGE was proven to be a diffusion-controlled process by conducting some measurements at different scan rates. The supporting electrolyte for the determination of CAF was studied, where 100 mM of sulfuric acid (H2SO4) provided the best result. Optimization of accumulation time, pulse size, and wave frequency were implemented and found to be 60 s accumulation time, 50 mV pulse size, and 25 Hz wave frequency. The stability of Gly/PGE was studied in different mediums, such as air, ultrapure water, and acetonitrile (CH3CN). Results: The determination of CAF under optimum conditions was within the linear concentration range of 0.1–75 μM, with a correlation coefficient of R2 = 0.9990. The limit of detection (LOD) and limit of quantification (LOQ) were 0.070 and 0.231 μM, respectively. Conclusion: An effective voltammetric methodology was suggested to determine CAF. This methodology has great promise to be applied in different matrices to determine CAF.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-07-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.2174/0115734110324545240725114425","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Caffeine (CAF) is a widely used chemical in foods and pharmaceuticals that is consumed by a lot of people every day. Overconsumption of caffeine can lead to some undesirable symptoms. However, CAF is considered a crucial nervous system stimulant. Aims: This study aimed to find an accurate and effective route for determining caffeine using voltammetric techniques. Objective: In this work, for the first time, a glycine (Gly) modified pencil graphite electrode (Gly/PGE) was used for the determination of caffeine (CAF) by Square Wave Adsorptive Stripping Voltammetry (SWAdSV) technique. Methods: The modification procedure of PGE by Gly was accomplished by performing the cyclic voltammetry (CV) technique for 10 cycles at a potential range of 0.8 to 1.8 V. Moreover, the characterization of Gly/PGE was done by applying the CV technique in aqueous and non-aqueous media and electrochemical impedance spectroscopy (EIS) in addition to the SEM technique. The movement type of CAF toward Gly/PGE was proven to be a diffusion-controlled process by conducting some measurements at different scan rates. The supporting electrolyte for the determination of CAF was studied, where 100 mM of sulfuric acid (H2SO4) provided the best result. Optimization of accumulation time, pulse size, and wave frequency were implemented and found to be 60 s accumulation time, 50 mV pulse size, and 25 Hz wave frequency. The stability of Gly/PGE was studied in different mediums, such as air, ultrapure water, and acetonitrile (CH3CN). Results: The determination of CAF under optimum conditions was within the linear concentration range of 0.1–75 μM, with a correlation coefficient of R2 = 0.9990. The limit of detection (LOD) and limit of quantification (LOQ) were 0.070 and 0.231 μM, respectively. Conclusion: An effective voltammetric methodology was suggested to determine CAF. This methodology has great promise to be applied in different matrices to determine CAF.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
甘氨酸改性铅笔石墨电极作为咖啡因测定传感器:伏安法研究
背景:咖啡因(CAF)是一种广泛应用于食品和药品的化学物质,每天都有很多人摄入。过量摄入咖啡因会导致一些不良症状。然而,咖啡因被认为是一种重要的神经系统兴奋剂。目的:本研究旨在找到一种利用伏安法测定咖啡因的准确而有效的方法。目的:本研究首次采用伏安法测定咖啡因:本研究首次使用甘氨酸(Gly)修饰的铅笔石墨电极(Gly/PGE),通过方波吸附剥离伏安法(SWAdSV)技术测定咖啡因(CAF)。方法:通过在 0.8 至 1.8 V 的电位范围内进行 10 个循环的循环伏安(CV)技术,完成了 Gly 对 PGE 的改性过程。此外,除了扫描电镜技术外,还在水介质和非水介质中应用了 CV 技术和电化学阻抗光谱(EIS)技术对 Gly/PGE 进行了表征。通过在不同扫描速率下进行一些测量,证明了 CAF 向 Gly/PGE 的移动类型是一个扩散控制过程。研究了测定 CAF 的辅助电解质,其中 100 mM 的硫酸 (H2SO4) 效果最佳。对累积时间、脉冲大小和波频进行了优化,发现累积时间为 60 秒,脉冲大小为 50 mV,波频为 25 Hz。研究了 Gly/PGE 在不同介质(如空气、超纯水和乙腈 (CH3CN))中的稳定性。结果显示在最佳条件下,CAF 的测定在 0.1-75 μM 的线性浓度范围内,相关系数为 R2 = 0.9990。检出限(LOD)和定量限(LOQ)分别为 0.070 和 0.231 μM。结论提出了一种有效的伏安法测定 CAF。该方法有望应用于不同基质中的 CAF 检测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
期刊最新文献
Management of Cholesteatoma: Hearing Rehabilitation. Congenital Cholesteatoma. Evaluation of Cholesteatoma. Management of Cholesteatoma: Extension Beyond Middle Ear/Mastoid. Recidivism and Recurrence.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1