Milana Kendrisic, Jonas Nienhaus, Vladislav Agafonov, Matthias Salas, Quang Nguyen, Hemma Resch, Clemens Vass, Wolfgang Drexler, Tilman Schmoll, Rainer A. Leitgeb
{"title":"Exploring single-mode VCSEL wavelength tuning for low-cost 3D optical coherence tomography and OCT angiography","authors":"Milana Kendrisic, Jonas Nienhaus, Vladislav Agafonov, Matthias Salas, Quang Nguyen, Hemma Resch, Clemens Vass, Wolfgang Drexler, Tilman Schmoll, Rainer A. Leitgeb","doi":"10.1364/boe.523081","DOIUrl":null,"url":null,"abstract":"Low-cost optical coherence tomography has recently emerged as a growing field due to the increased need for general availability of OCT devices outside of the clinics. One of the main obstacles in creating low-cost SS-OCT systems is the price of the laser. In this work, we study the influence of different tuning parameters (e.g., frequency, duty cycle, modulation curve, temperature) on the resulting bandwidth of the previously proposed low-cost single-mode thermally-tunable vertical-cavity surface-emitting laser (VCSEL) source at 850 nm. With optimal parameters, the laser achieves a tuning bandwidth of 10.2 nm at a 50 kHz A-scan rate. In addition, we show the first 3D rendered volume scans of both anterior and posterior segment using a custom VCSEL-based low-cost OCT setup. With the help of deep-learning-based denoising, it was possible to critically reduce the noise in single scans. Moreover, by investigating the phase stability, it became apparent that phase stability between sweeps increases with rising modulation frequencies, making the auxiliary interferometer obsolete. Thus, the system’s 50 kHz tuning regimen is also suitable for functional extensions such as OCT angiography.","PeriodicalId":8969,"journal":{"name":"Biomedical optics express","volume":null,"pages":null},"PeriodicalIF":2.9000,"publicationDate":"2024-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical optics express","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1364/boe.523081","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
Abstract
Low-cost optical coherence tomography has recently emerged as a growing field due to the increased need for general availability of OCT devices outside of the clinics. One of the main obstacles in creating low-cost SS-OCT systems is the price of the laser. In this work, we study the influence of different tuning parameters (e.g., frequency, duty cycle, modulation curve, temperature) on the resulting bandwidth of the previously proposed low-cost single-mode thermally-tunable vertical-cavity surface-emitting laser (VCSEL) source at 850 nm. With optimal parameters, the laser achieves a tuning bandwidth of 10.2 nm at a 50 kHz A-scan rate. In addition, we show the first 3D rendered volume scans of both anterior and posterior segment using a custom VCSEL-based low-cost OCT setup. With the help of deep-learning-based denoising, it was possible to critically reduce the noise in single scans. Moreover, by investigating the phase stability, it became apparent that phase stability between sweeps increases with rising modulation frequencies, making the auxiliary interferometer obsolete. Thus, the system’s 50 kHz tuning regimen is also suitable for functional extensions such as OCT angiography.
期刊介绍:
The journal''s scope encompasses fundamental research, technology development, biomedical studies and clinical applications. BOEx focuses on the leading edge topics in the field, including:
Tissue optics and spectroscopy
Novel microscopies
Optical coherence tomography
Diffuse and fluorescence tomography
Photoacoustic and multimodal imaging
Molecular imaging and therapies
Nanophotonic biosensing
Optical biophysics/photobiology
Microfluidic optical devices
Vision research.