{"title":"Effect of high‐range water reducer and W/C ratio on the fresh and mechanical properties of fiber‐reinforced natural zeolite SCC","authors":"Arash K. Pour, Amir Shirkhani, Ehsan Noroozinejad Farsangi","doi":"10.1002/suco.202301071","DOIUrl":null,"url":null,"abstract":"The present study aims to investigate how the use of high‐range water reducer (HRWR) and variations in water/cement (W/C) ratio affect the properties of self‐consolidating concrete (SCC) while taking into account different proportions of polypropylene fibers (PF) and natural zeolite (NZ). A total of 28 samples were cast and analyzed. PF fractions ranging from 0% to 1.5% by weight were added, along with a substitution of 10% NZ for cement (50 kg/m<jats:sup>3</jats:sup>). Four W/C ratios (0.30, 0.35, 0.40, and 0.45) were tested, in addition to seven HRWR contents ranging from 5 to 6.5 kg/m<jats:sup>3</jats:sup>. Various tests were conducted to assess slump, T<jats:sub>500</jats:sub>, V‐funnel, L‐box, modulus of elasticity, and compressive, tensile, and flexural strengths. Novel models were developed to predict the properties of hardened concrete based on W/C, HRWR, PF, and NZ content. Findings indicated that optimal performance of PF‐reinforced SCC with NZ was achieved when up to 0.75% PF was combined with an HRWR content equivalent to 1.25% of the cement fraction and NZ ratio. Furthermore, the proposed models offer accurate predictions of both fresh and hardened‐state properties of PF‐reinforced SCC with NZ based on W/C and HRWR ratios.","PeriodicalId":21988,"journal":{"name":"Structural Concrete","volume":null,"pages":null},"PeriodicalIF":3.0000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Structural Concrete","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1002/suco.202301071","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

The present study aims to investigate how the use of high‐range water reducer (HRWR) and variations in water/cement (W/C) ratio affect the properties of self‐consolidating concrete (SCC) while taking into account different proportions of polypropylene fibers (PF) and natural zeolite (NZ). A total of 28 samples were cast and analyzed. PF fractions ranging from 0% to 1.5% by weight were added, along with a substitution of 10% NZ for cement (50 kg/m3). Four W/C ratios (0.30, 0.35, 0.40, and 0.45) were tested, in addition to seven HRWR contents ranging from 5 to 6.5 kg/m3. Various tests were conducted to assess slump, T500, V‐funnel, L‐box, modulus of elasticity, and compressive, tensile, and flexural strengths. Novel models were developed to predict the properties of hardened concrete based on W/C, HRWR, PF, and NZ content. Findings indicated that optimal performance of PF‐reinforced SCC with NZ was achieved when up to 0.75% PF was combined with an HRWR content equivalent to 1.25% of the cement fraction and NZ ratio. Furthermore, the proposed models offer accurate predictions of both fresh and hardened‐state properties of PF‐reinforced SCC with NZ based on W/C and HRWR ratios.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
高范围减水剂和 W/C 比对纤维增强天然沸石 SCC 的新鲜度和力学性能的影响
本研究旨在探讨在考虑不同比例的聚丙烯纤维(PF)和天然沸石(NZ)的情况下,高程减水剂(HRWR)的使用和水灰比(W/C)的变化如何影响自密实混凝土(SCC)的性能。共浇注和分析了 28 个样品。按重量计,聚丙烯纤维的添加量从 0% 到 1.5%,同时用 10% 的天然沸石替代水泥(50 千克/立方米)。除了 5 至 6.5 公斤/立方米的七种 HRWR 含量外,还测试了四种 W/C(0.30、0.35、0.40 和 0.45)比率。进行了各种测试,以评估坍落度、T500、V 型隧道、L 型箱、弹性模量以及抗压、抗拉和抗弯强度。根据 W/C、HRWR、PF 和 NZ 含量,开发了预测硬化混凝土性能的新模型。研究结果表明,当 PF 含量高达 0.75%、HRWR 含量相当于水泥组分和 NZ 比率的 1.25%时,使用 NZ 的 PF 增强 SCC 可达到最佳性能。此外,根据 W/C 和 HRWR 比率,所提出的模型还能准确预测采用 NZ 的 PF 加固 SCC 的新鲜状态和硬化状态性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Structural Concrete
Structural Concrete CONSTRUCTION & BUILDING TECHNOLOGY-ENGINEERING, CIVIL
CiteScore
5.60
自引率
15.60%
发文量
284
审稿时长
3 months
期刊介绍: Structural Concrete, the official journal of the fib, provides conceptual and procedural guidance in the field of concrete construction, and features peer-reviewed papers, keynote research and industry news covering all aspects of the design, construction, performance in service and demolition of concrete structures. Main topics: design, construction, performance in service, conservation (assessment, maintenance, strengthening) and demolition of concrete structures research about the behaviour of concrete structures development of design methods fib Model Code sustainability of concrete structures.
期刊最新文献
Mechanical behavior of prestressed UHPC wind turbine tower columns under combined axial compression and bending Experimental investigation on mechanical property and hydration process of sintered sludge cement paste at different water‐binder ratios and curing ages Recent advances in embedded technologies and self‐sensing concrete for structural health monitoring Strut‐and‐tie model for column‐to‐drilled shaft connections in reinforced concrete bridge columns subjected to lateral loads Seismic performance of reinforced concrete stairs with new sliding support
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1