{"title":"Accuracy of the Dual Path Platform (DPP) rapid test for the diagnosis of leptospirosis: A multi-center study in six Brazilian states","authors":"Renata Aparecida Nascimento Ribeiro , Kátia Eliane Santos Avelar , Ilana Teruszkin Balassiano , Alexander Vargas , Edvar Yuri Pacheco Schubach , Rodrigo Menna Barreto Rodrigues , Lidsy Ximenes Fonseca , Vinícius Silva Belo","doi":"10.1016/j.actatropica.2024.107361","DOIUrl":null,"url":null,"abstract":"<div><p>Leptospirosis is a zoonotic disease with significant global impact and a challenging diagnosis. The utilization of adequately validated rapid tests is relevant for the opportune identification of the disease and for reduction in fatality rates. The present study analyzes the accuracy and reliability of the Dual Path Platform (DPP) assay -produced in Brazil by the Oswaldo Cruz Foundation (Fiocruz)- for diagnosing leptospirosis. Firstly, a serological panel was constructed in the Brazilian Reference Laboratory for Leptospirosis using samples routinely handled by reference laboratories of six Brazilian states. It consisted of 150 positive (according to MAT and IgM-ELISA) and 250 negative samples for leptospirosis. Subsequently, the panel samples were distributed to the reference laboratories for the performance of DPP assays in triplicate. Different measures were used in the assessment of diagnostic quality. Predictive values were estimated for different pre-test probability settings. Sensitivities varied between 67.33 % and 74.00 % and specificities between 93.20 % and 98.40 % in the states, and there were adequate agreements between them. Accuracies were lower for the samples of patients with less than 7 days of symptoms. In contexts of prevalence values up to around 25 %, positive and negative predictive values were around 90 %. However, in situations of high pre-test probabilities, NPVs were low. This study improves understanding of the use of DPP in diagnosing leptospirosis, particularly its application in healthcare settings. As long as the time of symptoms onset and clinical and epidemiological contexts are adequately considered for the interpretation of results, DPP is a valid option to be used in the leptospirosis diagnostic routine.</p></div>","PeriodicalId":7240,"journal":{"name":"Acta tropica","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2024-08-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta tropica","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0001706X24002432","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PARASITOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Leptospirosis is a zoonotic disease with significant global impact and a challenging diagnosis. The utilization of adequately validated rapid tests is relevant for the opportune identification of the disease and for reduction in fatality rates. The present study analyzes the accuracy and reliability of the Dual Path Platform (DPP) assay -produced in Brazil by the Oswaldo Cruz Foundation (Fiocruz)- for diagnosing leptospirosis. Firstly, a serological panel was constructed in the Brazilian Reference Laboratory for Leptospirosis using samples routinely handled by reference laboratories of six Brazilian states. It consisted of 150 positive (according to MAT and IgM-ELISA) and 250 negative samples for leptospirosis. Subsequently, the panel samples were distributed to the reference laboratories for the performance of DPP assays in triplicate. Different measures were used in the assessment of diagnostic quality. Predictive values were estimated for different pre-test probability settings. Sensitivities varied between 67.33 % and 74.00 % and specificities between 93.20 % and 98.40 % in the states, and there were adequate agreements between them. Accuracies were lower for the samples of patients with less than 7 days of symptoms. In contexts of prevalence values up to around 25 %, positive and negative predictive values were around 90 %. However, in situations of high pre-test probabilities, NPVs were low. This study improves understanding of the use of DPP in diagnosing leptospirosis, particularly its application in healthcare settings. As long as the time of symptoms onset and clinical and epidemiological contexts are adequately considered for the interpretation of results, DPP is a valid option to be used in the leptospirosis diagnostic routine.
期刊介绍:
Acta Tropica, is an international journal on infectious diseases that covers public health sciences and biomedical research with particular emphasis on topics relevant to human and animal health in the tropics and the subtropics.