Diane N. Sayah OD, PhD , Denise Descovich MD , Santiago Costantino PhD , Mark R. Lesk MD, MSc
{"title":"The Association between the Pulsatile Choroidal Volume Change and Ocular Rigidity","authors":"Diane N. Sayah OD, PhD , Denise Descovich MD , Santiago Costantino PhD , Mark R. Lesk MD, MSc","doi":"10.1016/j.xops.2024.100576","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><p>To assess the relationship between the pulsatile choroidal volume change (ΔV) and ocular rigidity (OR), an important biomechanical property of the eye.</p></div><div><h3>Design</h3><p>This is a prospective cross-sectional study.</p></div><div><h3>Subjects</h3><p>Two hundred seventeen participants (235 eyes) were included in this study. Of those, 18 eyes (18 participants) had exudative retinal disease, and 217 eyes (199 participants) had open-angle glaucoma (39.2%), suspect discs (12.4%), ocular hypertension (14.3%), or healthy eyes (34.1%).</p></div><div><h3>Methods</h3><p>Pulsatile choroidal volume change was measured using dynamic OCT, which detects the change in choroidal thickness during the cardiac cycle. Ocular rigidity was measured using an invasive procedure as well as using a validated optical method. Correlations between ΔV and OR were assessed in subjects with healthy eyes, eyes with glaucoma, or eyes with exudative retinal disease.</p></div><div><h3>Main Outcome Measures</h3><p>Ocular rigidity and pulsatile ocular volume change.</p></div><div><h3>Results</h3><p>In 18 eyes where OR was obtained invasively and ΔV was obtained noninvasively, a significant correlation was found between ΔV and OR (r<sub>s</sub> = −0.664, <em>P</em> = 0.003). Similarly, a strong inverse correlation was found between the noninvasive measurements of both ΔV and OR (r<sub>s</sub> = −0.748, <em>P</em> < 0.001) in a large cohort and maintained its significance across diagnostic groups (a more compliant eye is associated with greater ΔV). No correlation was found between ΔV and age, blood pressure, intraocular pressure, axial length, or diagnosis (<em>P</em> ≥ 0.05). Mean ΔV was 7.3 ± 3.4 μL for all groups combined with a range of 3.0 to 20.8 μL.</p></div><div><h3>Conclusions</h3><p>These results suggest an association between the biomechanics of the corneoscleral shell and pulsatile ocular blood flow, which may indicate that a more rigid eye exerts more resistance to pulsatile choroidal expansion. This highlights the dynamic nature of both blood flow and biomechanics in the eye, as well as how they may interact, leading to a greater understanding of the pathophysiology of ocular disease.</p></div><div><h3>Financial Disclosures</h3><p>Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.</p></div>","PeriodicalId":74363,"journal":{"name":"Ophthalmology science","volume":null,"pages":null},"PeriodicalIF":3.2000,"publicationDate":"2024-07-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S266691452400112X/pdfft?md5=ddd401d8b394fedad1dc8122bed5d1a8&pid=1-s2.0-S266691452400112X-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmology science","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S266691452400112X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose
To assess the relationship between the pulsatile choroidal volume change (ΔV) and ocular rigidity (OR), an important biomechanical property of the eye.
Design
This is a prospective cross-sectional study.
Subjects
Two hundred seventeen participants (235 eyes) were included in this study. Of those, 18 eyes (18 participants) had exudative retinal disease, and 217 eyes (199 participants) had open-angle glaucoma (39.2%), suspect discs (12.4%), ocular hypertension (14.3%), or healthy eyes (34.1%).
Methods
Pulsatile choroidal volume change was measured using dynamic OCT, which detects the change in choroidal thickness during the cardiac cycle. Ocular rigidity was measured using an invasive procedure as well as using a validated optical method. Correlations between ΔV and OR were assessed in subjects with healthy eyes, eyes with glaucoma, or eyes with exudative retinal disease.
Main Outcome Measures
Ocular rigidity and pulsatile ocular volume change.
Results
In 18 eyes where OR was obtained invasively and ΔV was obtained noninvasively, a significant correlation was found between ΔV and OR (rs = −0.664, P = 0.003). Similarly, a strong inverse correlation was found between the noninvasive measurements of both ΔV and OR (rs = −0.748, P < 0.001) in a large cohort and maintained its significance across diagnostic groups (a more compliant eye is associated with greater ΔV). No correlation was found between ΔV and age, blood pressure, intraocular pressure, axial length, or diagnosis (P ≥ 0.05). Mean ΔV was 7.3 ± 3.4 μL for all groups combined with a range of 3.0 to 20.8 μL.
Conclusions
These results suggest an association between the biomechanics of the corneoscleral shell and pulsatile ocular blood flow, which may indicate that a more rigid eye exerts more resistance to pulsatile choroidal expansion. This highlights the dynamic nature of both blood flow and biomechanics in the eye, as well as how they may interact, leading to a greater understanding of the pathophysiology of ocular disease.
Financial Disclosures
Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.