Computational analysis of the biomechanical stability of internal fixation of the lateral tibial plateau fracture: A mechanical stability study.

IF 1.7 4区 医学 Q3 ENGINEERING, BIOMEDICAL Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine Pub Date : 2024-08-01 Epub Date: 2024-08-24 DOI:10.1177/09544119241272782
Yafeng Li, Fengyuan Lu, Peng Yi, Zichun Zou, Xi Zhang, Jing Zhang
{"title":"Computational analysis of the biomechanical stability of internal fixation of the lateral tibial plateau fracture: A mechanical stability study.","authors":"Yafeng Li, Fengyuan Lu, Peng Yi, Zichun Zou, Xi Zhang, Jing Zhang","doi":"10.1177/09544119241272782","DOIUrl":null,"url":null,"abstract":"<p><p>The selection of internal fixation as the primary fixation modality for the patient is one of the challenges for the surgeon treating the patient in question. A model of the lateral tibial plateau fracture was established. Three different configurations of internal fixators namely L bone plate, T bone plate, and screw-washer were analyzed. Three stages after surgery were simulated to assess the displacement of bone plates, screws, washers, and the stress shielding ratio in the fracture area.At three stages after surgery, the T bone plate showed better stability for patients during rehabilitation compared with the remaining two schemes, and the screw-washer scheme was the least stable due to the larger internal fixation displacement and stress shielding ratio in the fracture area. In contrast, the L bone plate scheme showed better stability in the early stages after surgery but was second only to the screw-washer scheme in the middle and late stages after surgery. The T bone plate showed better stability and became a new selection for surgeons to treat related patients. At three stages after surgery, the T bone plate has better biomechanical stability compared to the L bone plate and screw-washer schemes.</p>","PeriodicalId":20666,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine","volume":" ","pages":"897-908"},"PeriodicalIF":1.7000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/09544119241272782","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/24 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The selection of internal fixation as the primary fixation modality for the patient is one of the challenges for the surgeon treating the patient in question. A model of the lateral tibial plateau fracture was established. Three different configurations of internal fixators namely L bone plate, T bone plate, and screw-washer were analyzed. Three stages after surgery were simulated to assess the displacement of bone plates, screws, washers, and the stress shielding ratio in the fracture area.At three stages after surgery, the T bone plate showed better stability for patients during rehabilitation compared with the remaining two schemes, and the screw-washer scheme was the least stable due to the larger internal fixation displacement and stress shielding ratio in the fracture area. In contrast, the L bone plate scheme showed better stability in the early stages after surgery but was second only to the screw-washer scheme in the middle and late stages after surgery. The T bone plate showed better stability and became a new selection for surgeons to treat related patients. At three stages after surgery, the T bone plate has better biomechanical stability compared to the L bone plate and screw-washer schemes.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
胫骨外侧平台骨折内固定的生物力学稳定性计算分析:机械稳定性研究。
选择内固定作为患者的主要固定方式,是外科医生在治疗患者时面临的挑战之一。我们建立了一个胫骨外侧平台骨折模型。分析了三种不同配置的内固定器,即 L 型骨板、T 型骨板和螺钉垫圈。模拟术后三个阶段,评估骨板、螺钉、垫圈的位移以及骨折区域的应力屏蔽比。术后三个阶段,T 型骨板与其余两种方案相比,在患者康复期间表现出更好的稳定性,而螺钉垫圈方案由于骨折区域的内固定位移和应力屏蔽比较大,稳定性最差。相比之下,L 型骨板方案在术后早期的稳定性较好,但在术后中后期的稳定性仅次于螺钉垫圈方案。T 型骨板显示出更好的稳定性,成为外科医生治疗相关患者的新选择。在术后三个阶段,与 L 型骨板和螺钉垫圈方案相比,T 型骨板具有更好的生物力学稳定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.60
自引率
5.60%
发文量
122
审稿时长
6 months
期刊介绍: The Journal of Engineering in Medicine is an interdisciplinary journal encompassing all aspects of engineering in medicine. The Journal is a vital tool for maintaining an understanding of the newest techniques and research in medical engineering.
期刊最新文献
Effects of self-expandable pedicle screws with shape memory alloy structures on spinal fixation strength: A finite element study. A systematic review of energy storing dynamic response foot for prosthetic rehabilitation. Cortical bone fracture analysis including the combined influence of osteon orientations, applied load and crack lengths: A numerical investigation. A wavelet and local binary pattern-based feature descriptor for the detection of chronic infection through thoracic X-ray images. Optimization and control of robotic vertebral plate grinding: Predictive modeling, parameter optimization, and fuzzy control strategies for minimizing bone damage in laminectomy procedures.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1