{"title":"Simultaneous determination of icotinib, osimertinib, aumolertinib, and anlotinib in human plasma for therapeutic drug monitoring by UPLC-MS/MS","authors":"Yuxiang Xu , Hongxin Qie , Haopeng Zhao , Xiaonan Gao , Jinglin Gao , Zhangying Feng , Jing Bai , Mingxia Wang","doi":"10.1016/j.jpba.2024.116445","DOIUrl":null,"url":null,"abstract":"<div><p>Epidermal growth factor receptor tyrosine kinase inhibitors (EGFR-TKIs) such as icotinib, osimertinib, and aumolertinib have emerged as promising treatment options for EGFR mutated Non-small cell lung cancer (NSCLC) patients. Additionally, anlotinib, an anti-angiogenic agent targeting VEGFR, FGFR, and PDGFR, has been used in combination with EGFR-TKIs in NSCLC cases. A method utilizing ultrahigh performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed and validated for quantifying icotinib, osimertinib, aumolertinib and anlotinib simultaneously in clinical TDM. The chromatographic separation was performed using a Kinetex C18 column (100 mm × 2.1 mm) and an elution gradient of ammonium acetate in water acidified with 0.1 % formic acid and in acetonitrile. The assay was validated over a linear range of 4–2000 ng/mL for icotinib, 2–1000 ng/mL for osimertinib, 1–500 ng/mL for aumolertinib, and 0.8–400 ng/mL for anlotinib, following the guidelines on bioanalytical methods by FDA. The quantification method exhibited satisfactory performance in terms of selectivity, accuracy (from 91.3 % to 107 %), precision (intra- and inter-day coeffficients of variation ranged from 0.944 % to 7.48 %), linearity, recovery (from 86.0 % to 91.9 %), matrix effect (IS-normalized matrix factors were from 96.7 % to 102 %), and stability. Overall, the method proved to be sensitive, reliable, and straightforward, enabling successful simultaneous determination of blood concentrations of icotinib, osimertinib, aumolertinib, and anlotinib in patients. The validity of the method has been confirmed across various instruments.</p></div>","PeriodicalId":16685,"journal":{"name":"Journal of pharmaceutical and biomedical analysis","volume":"251 ","pages":"Article 116445"},"PeriodicalIF":3.1000,"publicationDate":"2024-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0731708524004850/pdfft?md5=eabcaf22da913814b318217df0e8d2a0&pid=1-s2.0-S0731708524004850-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of pharmaceutical and biomedical analysis","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0731708524004850","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/22 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Epidermal growth factor receptor tyrosine kinase inhibitors (EGFR-TKIs) such as icotinib, osimertinib, and aumolertinib have emerged as promising treatment options for EGFR mutated Non-small cell lung cancer (NSCLC) patients. Additionally, anlotinib, an anti-angiogenic agent targeting VEGFR, FGFR, and PDGFR, has been used in combination with EGFR-TKIs in NSCLC cases. A method utilizing ultrahigh performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed and validated for quantifying icotinib, osimertinib, aumolertinib and anlotinib simultaneously in clinical TDM. The chromatographic separation was performed using a Kinetex C18 column (100 mm × 2.1 mm) and an elution gradient of ammonium acetate in water acidified with 0.1 % formic acid and in acetonitrile. The assay was validated over a linear range of 4–2000 ng/mL for icotinib, 2–1000 ng/mL for osimertinib, 1–500 ng/mL for aumolertinib, and 0.8–400 ng/mL for anlotinib, following the guidelines on bioanalytical methods by FDA. The quantification method exhibited satisfactory performance in terms of selectivity, accuracy (from 91.3 % to 107 %), precision (intra- and inter-day coeffficients of variation ranged from 0.944 % to 7.48 %), linearity, recovery (from 86.0 % to 91.9 %), matrix effect (IS-normalized matrix factors were from 96.7 % to 102 %), and stability. Overall, the method proved to be sensitive, reliable, and straightforward, enabling successful simultaneous determination of blood concentrations of icotinib, osimertinib, aumolertinib, and anlotinib in patients. The validity of the method has been confirmed across various instruments.
期刊介绍:
This journal is an international medium directed towards the needs of academic, clinical, government and industrial analysis by publishing original research reports and critical reviews on pharmaceutical and biomedical analysis. It covers the interdisciplinary aspects of analysis in the pharmaceutical, biomedical and clinical sciences, including developments in analytical methodology, instrumentation, computation and interpretation. Submissions on novel applications focusing on drug purity and stability studies, pharmacokinetics, therapeutic monitoring, metabolic profiling; drug-related aspects of analytical biochemistry and forensic toxicology; quality assurance in the pharmaceutical industry are also welcome.
Studies from areas of well established and poorly selective methods, such as UV-VIS spectrophotometry (including derivative and multi-wavelength measurements), basic electroanalytical (potentiometric, polarographic and voltammetric) methods, fluorimetry, flow-injection analysis, etc. are accepted for publication in exceptional cases only, if a unique and substantial advantage over presently known systems is demonstrated. The same applies to the assay of simple drug formulations by any kind of methods and the determination of drugs in biological samples based merely on spiked samples. Drug purity/stability studies should contain information on the structure elucidation of the impurities/degradants.