Clinical Effect of Personalized Adjustable Mandibular Advancement Device on Obstructive Sleep Apnea.

IF 1 4区 医学 Q3 MEDICINE, GENERAL & INTERNAL British journal of hospital medicine Pub Date : 2024-08-30 Epub Date: 2024-08-19 DOI:10.12968/hmed.2024.0189
Wei Wang, Jian Pang, Yi-Xue Zhang, Yi-Meng Mo, Jiao Zhang, Zhen-Hui Wei
{"title":"Clinical Effect of Personalized Adjustable Mandibular Advancement Device on Obstructive Sleep Apnea.","authors":"Wei Wang, Jian Pang, Yi-Xue Zhang, Yi-Meng Mo, Jiao Zhang, Zhen-Hui Wei","doi":"10.12968/hmed.2024.0189","DOIUrl":null,"url":null,"abstract":"<p><p><b>Aims/Background:</b> Mandibular advancement devices are effective in treating mild or moderate obstructive sleep apnea (OSA), but such devices that are commonly used in clinical settings require further improvement. In this study, we evaluated the clinical effects of personalized adjustable mandibular advancement devices on mild or moderate OSA. <b>Methods:</b> Forty patients with mild or moderate OSA were randomly divided into experimental (personalized adjustable device) and control (traditional device) groups. Side effects, including increased salivation, dry mouth, muscle aches, and temporomandibular joint discomfort, were assessed. Respiratory markers during sleep, including the apnea-hypopnea index, mean blood oxygen saturation, lowest blood oxygen saturation and maximum apnea time, were evaluated using polysomnography. The upper airway cross-sectional area and temporomandibular joint morphology and motion trajectory were evaluated using cone beam computed tomography. <b>Results:</b> Side effects were significantly lower in the experimental group than in the control group. Respiratory marker levels were significantly restored post-treatment. Soft palate- and tongue-pharyngeal cross-sectional areas were significantly increased in both groups, but temporomandibular joint morphology or motion trajectory remained unchanged. <b>Conclusion:</b> The personalized adjustable mandibular advancement devices may reduce side effects and are effective in treating patients with OSA. <b>Clinical Trial Registration:</b> The study was registered and approved by the Chinese Clinical Trial Registry (ChiCTR2400080306). https://www.chictr.org.cn/showproj.html?proj=206538.</p>","PeriodicalId":9256,"journal":{"name":"British journal of hospital medicine","volume":"85 8","pages":"1-17"},"PeriodicalIF":1.0000,"publicationDate":"2024-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"British journal of hospital medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.12968/hmed.2024.0189","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/19 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Aims/Background: Mandibular advancement devices are effective in treating mild or moderate obstructive sleep apnea (OSA), but such devices that are commonly used in clinical settings require further improvement. In this study, we evaluated the clinical effects of personalized adjustable mandibular advancement devices on mild or moderate OSA. Methods: Forty patients with mild or moderate OSA were randomly divided into experimental (personalized adjustable device) and control (traditional device) groups. Side effects, including increased salivation, dry mouth, muscle aches, and temporomandibular joint discomfort, were assessed. Respiratory markers during sleep, including the apnea-hypopnea index, mean blood oxygen saturation, lowest blood oxygen saturation and maximum apnea time, were evaluated using polysomnography. The upper airway cross-sectional area and temporomandibular joint morphology and motion trajectory were evaluated using cone beam computed tomography. Results: Side effects were significantly lower in the experimental group than in the control group. Respiratory marker levels were significantly restored post-treatment. Soft palate- and tongue-pharyngeal cross-sectional areas were significantly increased in both groups, but temporomandibular joint morphology or motion trajectory remained unchanged. Conclusion: The personalized adjustable mandibular advancement devices may reduce side effects and are effective in treating patients with OSA. Clinical Trial Registration: The study was registered and approved by the Chinese Clinical Trial Registry (ChiCTR2400080306). https://www.chictr.org.cn/showproj.html?proj=206538.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
个性化可调下颌前突矫正器对阻塞性睡眠呼吸暂停的临床效果。
目的/背景:下颌前突矫正器可有效治疗轻度或中度阻塞性睡眠呼吸暂停(OSA),但临床上常用的此类矫正器还需要进一步改进。在这项研究中,我们评估了个性化可调下颌前突矫正器对轻度或中度 OSA 的临床效果。研究方法将 40 名轻度或中度 OSA 患者随机分为实验组(个性化可调装置)和对照组(传统装置)。对副作用进行评估,包括唾液增多、口干、肌肉酸痛和颞下颌关节不适。使用多导睡眠图评估了睡眠期间的呼吸指标,包括呼吸暂停-低通气指数、平均血氧饱和度、最低血氧饱和度和最长呼吸暂停时间。锥形束计算机断层扫描对上气道横截面积和颞下颌关节形态及运动轨迹进行了评估。结果显示实验组的副作用明显低于对照组。治疗后呼吸标志物水平明显恢复。两组患者的软腭和舌咽横截面积均明显增加,但颞下颌关节形态或运动轨迹保持不变。结论个性化可调下颌前突装置可减少副作用,对治疗 OSA 患者有效。临床试验注册:本研究已在中国临床试验注册中心注册并获得批准(ChiCTR2400080306)。https://www.chictr.org.cn/showproj.html?proj=206538。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
British journal of hospital medicine
British journal of hospital medicine 医学-医学:内科
CiteScore
1.50
自引率
0.00%
发文量
176
审稿时长
4-8 weeks
期刊介绍: British Journal of Hospital Medicine was established in 1966, and is still true to its origins: a monthly, peer-reviewed, multidisciplinary review journal for hospital doctors and doctors in training. The journal publishes an authoritative mix of clinical reviews, education and training updates, quality improvement projects and case reports, and book reviews from recognized leaders in the profession. The Core Training for Doctors section provides clinical information in an easily accessible format for doctors in training. British Journal of Hospital Medicine is an invaluable resource for hospital doctors at all stages of their career. The journal is indexed on Medline, CINAHL, the Sociedad Iberoamericana de Información Científica and Scopus.
期刊最新文献
Analysis of Risk Factors and Establishment of a Risk Prediction Model for Severe Postpartum Haemorrhage. Analysis of the Efficacy and Safety of Benzbromarone Combined with Sodium Bicarbonate Tablets in the Treatment of Hyperuricemia. Comparison of Effects between Nasal Bi-Level Positive Airway Pressure and Nasal Synchronized Intermittent Mandatory Ventilation in Neonatal Respiratory Distress Syndrome. Antimicrobial Stewardship in the Frail Elderly. Application of Intelligent Management Model Based on Electronic Patient-Reported Outcome During Immunotherapy in Patients with Gastric Cancer: A Single-Center Retrospective Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1