Implantation of CRT pacemaker during pregnancy: estimated fetal radiation dose.

Pub Date : 2024-09-19 DOI:10.1093/rpd/ncae182
Anna-Leena Manninen, Jukka Järvinen, Joanna Sierpowska, Timo J Mäkelä, Tuomas T Rissanen
{"title":"Implantation of CRT pacemaker during pregnancy: estimated fetal radiation dose.","authors":"Anna-Leena Manninen, Jukka Järvinen, Joanna Sierpowska, Timo J Mäkelä, Tuomas T Rissanen","doi":"10.1093/rpd/ncae182","DOIUrl":null,"url":null,"abstract":"<p><p>The benefits of a cardiac resynchronization therapy (CRT) implantation are known in severe heart failure and its implantation may also be considered during pregnancy to ensure safe pregnancy and delivery for both the mother and the fetus. This study on a patient case aimed to estimate the absorbed dose (AD) to the fetus during the CRT implantation of 21st week of the pregnant woman. AD measurement was done using anthropomorphic phantom, radiophotoluminescence dosemeters and Monte Carlo simulation utilizing kerma area product (KAP) of the procedures. The measured AD for a phantom's uterus and heart was 0.116 and 14.7 mGy with total KAP of 27.9 Gycm2. The estimated actual AD to the fetus and the mother's heart was 0.004 and 1.2 mGy, with total KAP of 1.5 Gycm2. The dose to the fetus can be minimized with the optimized procedure.</p>","PeriodicalId":0,"journal":{"name":"","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2024-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1093/rpd/ncae182","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The benefits of a cardiac resynchronization therapy (CRT) implantation are known in severe heart failure and its implantation may also be considered during pregnancy to ensure safe pregnancy and delivery for both the mother and the fetus. This study on a patient case aimed to estimate the absorbed dose (AD) to the fetus during the CRT implantation of 21st week of the pregnant woman. AD measurement was done using anthropomorphic phantom, radiophotoluminescence dosemeters and Monte Carlo simulation utilizing kerma area product (KAP) of the procedures. The measured AD for a phantom's uterus and heart was 0.116 and 14.7 mGy with total KAP of 27.9 Gycm2. The estimated actual AD to the fetus and the mother's heart was 0.004 and 1.2 mGy, with total KAP of 1.5 Gycm2. The dose to the fetus can be minimized with the optimized procedure.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
孕期植入 CRT 起搏器:胎儿辐射剂量估算。
众所周知,心脏再同步化疗法(CRT)植入对严重心力衰竭患者有好处,在怀孕期间也可考虑植入,以确保母亲和胎儿的安全妊娠和分娩。本研究针对一例患者,旨在估算孕妇在第 21 周植入 CRT 时胎儿的吸收剂量(AD)。吸收剂量的测量采用了拟人化模型、放射光剂量计和蒙特卡洛模拟,利用的是手术过程中的切口面积乘积(KAP)。测得的模型子宫和心脏的 AD 分别为 0.116 和 14.7 mGy,总 KAP 为 27.9 Gycm2。估计胎儿和母亲心脏的实际 AD 分别为 0.004 和 1.2 mGy,总 KAP 为 1.5 Gycm2。通过优化程序,可将胎儿所受剂量降至最低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1