The effect of extended periods of mini-scleral lens wear on the conjunctival/episcleral and scleral thickness.

IF 4.1 3区 医学 Q1 OPHTHALMOLOGY Contact Lens & Anterior Eye Pub Date : 2024-08-30 DOI:10.1016/j.clae.2024.102289
Ruveyde Bolac, Merve Beyza Yıldız, Oksan Alpogan, Yasemin Un, Mehmet Serhat Mangan
{"title":"The effect of extended periods of mini-scleral lens wear on the conjunctival/episcleral and scleral thickness.","authors":"Ruveyde Bolac, Merve Beyza Yıldız, Oksan Alpogan, Yasemin Un, Mehmet Serhat Mangan","doi":"10.1016/j.clae.2024.102289","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the conjunctival/episcleral thickness (CET) and anterior scleral thickness (AST) in patients with keratoconus with an extended duration of mini-scleral contact lens wear by utilizing anterior segment optical coherence tomography (ASOCT).</p><p><strong>Methods: </strong>This study included 17 eyes of 17 patients with keratoconus with mini-scleral contact lens wear (Group 1), 20 eyes of 20 patients with keratoconus without any contact lens wear (Group 2), and 20 eyes of 20 healthy controls (Group 3). CET and AST were measured using AS-OCT (Triton, Topcon, Japan) at 1, 2, and 3 mm posterior to the scleral spur in the nasal, temporal, superior, and inferior quadrants.</p><p><strong>Results: </strong>The median age of the mini-scleral contact lens group was 26, and the number of male patients was 14 (82.4 %). The superior CET values at 1 mm, 2 mm, and 3 mm statistically differed between the groups, with Group 1 having significantly lower values than Group 3 and Group 2 having statistically similar values to the remaining two groups. The inferior CET at 2 mm was lower in Groups 1 and 2 than in Group 3. The inferior CET at 3 mm was lower in Group 1 compared to Groups 2 and 3. AST was similar between the groups at all measured quadrants and distances. The duration of lens wear had a strong, statistically significant, negative correlation with the superior CET at 2 mm (rho: -0.847, p < 0.001) and a moderate, statistically significant, negative correlation with the superior CET at 3 mm (rho: -0.506, p < 0.038).</p><p><strong>Conclusions: </strong>In this study, it was found that mini-scleral contact lens usage causes thinning in the conjunctival-episcleral layer, especially in the superior and inferior quadrants, but does not affect scleral thickness. AS-OCT is a non-invasive and clinically applicable technique for assessing the impact of contact lens use on the conjunctiva/episclera and sclera.</p>","PeriodicalId":49087,"journal":{"name":"Contact Lens & Anterior Eye","volume":" ","pages":"102289"},"PeriodicalIF":4.1000,"publicationDate":"2024-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Contact Lens & Anterior Eye","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.clae.2024.102289","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To evaluate the conjunctival/episcleral thickness (CET) and anterior scleral thickness (AST) in patients with keratoconus with an extended duration of mini-scleral contact lens wear by utilizing anterior segment optical coherence tomography (ASOCT).

Methods: This study included 17 eyes of 17 patients with keratoconus with mini-scleral contact lens wear (Group 1), 20 eyes of 20 patients with keratoconus without any contact lens wear (Group 2), and 20 eyes of 20 healthy controls (Group 3). CET and AST were measured using AS-OCT (Triton, Topcon, Japan) at 1, 2, and 3 mm posterior to the scleral spur in the nasal, temporal, superior, and inferior quadrants.

Results: The median age of the mini-scleral contact lens group was 26, and the number of male patients was 14 (82.4 %). The superior CET values at 1 mm, 2 mm, and 3 mm statistically differed between the groups, with Group 1 having significantly lower values than Group 3 and Group 2 having statistically similar values to the remaining two groups. The inferior CET at 2 mm was lower in Groups 1 and 2 than in Group 3. The inferior CET at 3 mm was lower in Group 1 compared to Groups 2 and 3. AST was similar between the groups at all measured quadrants and distances. The duration of lens wear had a strong, statistically significant, negative correlation with the superior CET at 2 mm (rho: -0.847, p < 0.001) and a moderate, statistically significant, negative correlation with the superior CET at 3 mm (rho: -0.506, p < 0.038).

Conclusions: In this study, it was found that mini-scleral contact lens usage causes thinning in the conjunctival-episcleral layer, especially in the superior and inferior quadrants, but does not affect scleral thickness. AS-OCT is a non-invasive and clinically applicable technique for assessing the impact of contact lens use on the conjunctiva/episclera and sclera.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
长时间佩戴微型巩膜透镜对结膜/巩膜外膜和巩膜厚度的影响。
目的:利用前节光学相干断层扫描(ASOCT)评估长期佩戴微型巩膜接触镜的角膜病患者的结膜/巩膜外膜厚度(CET)和前巩膜厚度(AST):本研究包括 17 名佩戴微型巩膜接触镜的角膜病患者的 17 只眼睛(第 1 组)、20 名未佩戴任何接触镜的角膜病患者的 20 只眼睛(第 2 组)和 20 名健康对照者的 20 只眼睛(第 3 组)。使用 AS-OCT(Triton,日本拓普康公司)在鼻、颞、上和下象限巩膜骨刺后 1、2 和 3 毫米处测量 CET 和 AST:迷你巩膜接触镜组的中位年龄为 26 岁,男性患者为 14 人(82.4%)。各组在 1 毫米、2 毫米和 3 毫米处的上部 CET 值在统计学上存在差异,第一组的值明显低于第三组,而第二组的值在统计学上与其余两组相似。第 1 组和第 2 组 2 毫米处的下部 CET 低于第 3 组,第 1 组 3 毫米处的下部 CET 低于第 2 组和第 3 组。在所有测量的象限和距离上,各组之间的 AST 相似。镜片配戴时间与 2 毫米处的上部 CET 呈显著负相关(rho:-0.847,p 结论:本研究发现,佩戴微型巩膜接触镜会导致结膜-巩膜外层变薄,尤其是在上象限和下象限,但不会影响巩膜厚度。AS-OCT 是一种非侵入性且适用于临床的技术,可用于评估使用隐形眼镜对结膜/巩膜和巩膜的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
7.60
自引率
18.80%
发文量
198
审稿时长
55 days
期刊介绍: Contact Lens & Anterior Eye is a research-based journal covering all aspects of contact lens theory and practice, including original articles on invention and innovations, as well as the regular features of: Case Reports; Literary Reviews; Editorials; Instrumentation and Techniques and Dates of Professional Meetings.
期刊最新文献
Validation and repeatability assessment of the Chinese version of the Ocular Surface Disease Index (OSDI), 5-item dry eye (DEQ-5), and contact lens dry eye questionnaire-8 (CLDEQ-8) questionnaires. Artificial intelligence-assisted fitting method using corneal topography outcomes enhances success rate in orthokeratology lens fitting. Randomised controlled trial on effects of topical insulin compared to artificial tears and normal saline on tear inflammatory mediator levels and clinical parameters in diabetics with dry eye disease. Development and evaluation of ocular antibiotic-loaded soluble film inserts. Digital eye strain and clinical correlates in older adults.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1