Min Zhou, Zhuang Nie, Jie Zhao, Yao Xiao, Xiaohua Hong, Yuhui Wang, Chengjun Dong, Alexander P Lin, Ziqiao Lei
{"title":"Optimization and validation of echo times of point-resolved spectroscopy for cystathionine detection in gliomas.","authors":"Min Zhou, Zhuang Nie, Jie Zhao, Yao Xiao, Xiaohua Hong, Yuhui Wang, Chengjun Dong, Alexander P Lin, Ziqiao Lei","doi":"10.1186/s40644-024-00764-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Cystathionine accumulates selectively in 1p/19q-codeleted gliomas, and can serve as a possible noninvasive biomarker. This study aims to optimize the echo time (TE) of point-resolved spectroscopy (PRESS) for cystathionine detection in gliomas, and evaluate the diagnostic accuracy of PRESS for 1p/19q-codeletion identification.</p><p><strong>Methods: </strong>The TE of PRESS was optimized with numerical and phantom analysis to better resolve cystathionine from the overlapping aspartate multiplets. The optimized and 97 ms TE PRESS were then applied to 84 prospectively enrolled patients suspected of glioma or glioma recurrence to examine the influence of aspartate on cystathionine quantification by fitting the spectra with and without aspartate. The diagnostic performance of PRESS for 1p/19q-codeleted gliomas were assessed.</p><p><strong>Results: </strong>The TE of PRESS was optimized as (TE1, TE2) = (17 ms, 28 ms). The spectral pattern of cystathionine and aspartate were consistent between calculation and phantom. The mean concentrations of cystathionine in vivo fitting without aspartate were significantly higher than those fitting with full basis-set for 97 ms TE PRESS (1.97 ± 2.01 mM vs. 1.55 ± 1.95 mM, p < 0.01), but not significantly different for 45 ms method (0.801 ± 1.217 mM and 0.796 ± 1.217 mM, p = 0.494). The cystathionine concentrations of 45 ms approach was better correlated with those of edited MRS than 97 ms counterparts (r = 0.68 vs. 0.49, both p < 0.01). The sensitivity and specificity for discriminating 1p/19q-codeleted gliomas were 66.7% and 73.7% for 45 ms method, and 44.4% and 52.5% for 97 ms method, respectively.</p><p><strong>Conclusion: </strong>The 45 ms TE PRESS yields more precise cystathionine estimates than the 97 ms method, and is anticipated to facilitate noninvasive diagnosis of 1p/19q-codeleted gliomas, and treatment response monitoring in those patients. Medium diagnostic performance of PRESS for 1p/19q-codeleted gliomas were observed, and warrants further investigations.</p>","PeriodicalId":9548,"journal":{"name":"Cancer Imaging","volume":"24 1","pages":"118"},"PeriodicalIF":3.5000,"publicationDate":"2024-09-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11367870/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cancer Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40644-024-00764-x","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Cystathionine accumulates selectively in 1p/19q-codeleted gliomas, and can serve as a possible noninvasive biomarker. This study aims to optimize the echo time (TE) of point-resolved spectroscopy (PRESS) for cystathionine detection in gliomas, and evaluate the diagnostic accuracy of PRESS for 1p/19q-codeletion identification.
Methods: The TE of PRESS was optimized with numerical and phantom analysis to better resolve cystathionine from the overlapping aspartate multiplets. The optimized and 97 ms TE PRESS were then applied to 84 prospectively enrolled patients suspected of glioma or glioma recurrence to examine the influence of aspartate on cystathionine quantification by fitting the spectra with and without aspartate. The diagnostic performance of PRESS for 1p/19q-codeleted gliomas were assessed.
Results: The TE of PRESS was optimized as (TE1, TE2) = (17 ms, 28 ms). The spectral pattern of cystathionine and aspartate were consistent between calculation and phantom. The mean concentrations of cystathionine in vivo fitting without aspartate were significantly higher than those fitting with full basis-set for 97 ms TE PRESS (1.97 ± 2.01 mM vs. 1.55 ± 1.95 mM, p < 0.01), but not significantly different for 45 ms method (0.801 ± 1.217 mM and 0.796 ± 1.217 mM, p = 0.494). The cystathionine concentrations of 45 ms approach was better correlated with those of edited MRS than 97 ms counterparts (r = 0.68 vs. 0.49, both p < 0.01). The sensitivity and specificity for discriminating 1p/19q-codeleted gliomas were 66.7% and 73.7% for 45 ms method, and 44.4% and 52.5% for 97 ms method, respectively.
Conclusion: The 45 ms TE PRESS yields more precise cystathionine estimates than the 97 ms method, and is anticipated to facilitate noninvasive diagnosis of 1p/19q-codeleted gliomas, and treatment response monitoring in those patients. Medium diagnostic performance of PRESS for 1p/19q-codeleted gliomas were observed, and warrants further investigations.
Cancer ImagingONCOLOGY-RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
CiteScore
7.00
自引率
0.00%
发文量
66
审稿时长
>12 weeks
期刊介绍:
Cancer Imaging is an open access, peer-reviewed journal publishing original articles, reviews and editorials written by expert international radiologists working in oncology.
The journal encompasses CT, MR, PET, ultrasound, radionuclide and multimodal imaging in all kinds of malignant tumours, plus new developments, techniques and innovations. Topics of interest include:
Breast Imaging
Chest
Complications of treatment
Ear, Nose & Throat
Gastrointestinal
Hepatobiliary & Pancreatic
Imaging biomarkers
Interventional
Lymphoma
Measurement of tumour response
Molecular functional imaging
Musculoskeletal
Neuro oncology
Nuclear Medicine
Paediatric.