The Mitris RESILIA Valve: New Skin for a Proven Design.

IF 0.8 Q4 SURGERY Surgical technology international Pub Date : 2024-07-15 DOI:10.52198/24.STI.44.CV1792
Giulia Ciccarelli, Luca Weltert, Raffaele Scaffa, Andrea Salica, Alessandro Bellisario, Alessandro Ricci, Salvatore D'Aleo, Samuel Fusca, Lorenzo Guerrieri Wolf, Giulio Folino, Gino Gerosa, Ruggero De Paulis
{"title":"The Mitris RESILIA Valve: New Skin for a Proven Design.","authors":"Giulia Ciccarelli, Luca Weltert, Raffaele Scaffa, Andrea Salica, Alessandro Bellisario, Alessandro Ricci, Salvatore D'Aleo, Samuel Fusca, Lorenzo Guerrieri Wolf, Giulio Folino, Gino Gerosa, Ruggero De Paulis","doi":"10.52198/24.STI.44.CV1792","DOIUrl":null,"url":null,"abstract":"<p><p>By incorporating the best features of the Carpentier-Edwards PERIMOUNT Magna Mitral Ease valve (Edwards Lifesciences Corporation, Irvine, California) and INSPIRIS RESILIA tissue (Edwards Lifesciences Corporation, Irvine, California), the mitris valve inherits the advantages of the remarkable hemodynamic performance of the former and the durability of the latter. In this paper, we will summarize the process that led to the creation of this new valve and report on the first implant's feasibility and first impression. The mitris valve has an overall implantability profile, overlapping the previous generation with no added challenges, but compared to the PERIMOUNT Magna Mitral Ease valve, the mitris valve boasts a more pliable saddle-shaped sewing cuff that is specifically tailored to fit the complex structure of the mitral valve with a lower stent height. This could be particularly beneficial in the context of double-valve replacement, as it may prevent any disturbance to the bioprosthesis located in the aortic position in small annulus. This could also prevent some rare but unpleasant complications such as left ventricle outflow obstruction or rupture of the atrioventricular sulcus. In addition, it could allow for better adherence to the saddle-shaped annulus of the mitral valve with the possibility of less stress (and therefore fibrosis) on the valve tissue, while further reducing the degeneration time. Furthermore, thanks to the possibility of being temporarily adjusted inwards, it is possible to ensure greater implantability compared to the previous generation of Magna Edwards mitral valves. Thanks to INSPIRIS technology, which prevents the generation of free aldehydes that promote oxidation and calcification of pericardial tissue, it is possible to assume that the durability will probably also improve. This reinforces the trustworthiness of the mitris valve.</p>","PeriodicalId":22194,"journal":{"name":"Surgical technology international","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2024-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Surgical technology international","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52198/24.STI.44.CV1792","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

By incorporating the best features of the Carpentier-Edwards PERIMOUNT Magna Mitral Ease valve (Edwards Lifesciences Corporation, Irvine, California) and INSPIRIS RESILIA tissue (Edwards Lifesciences Corporation, Irvine, California), the mitris valve inherits the advantages of the remarkable hemodynamic performance of the former and the durability of the latter. In this paper, we will summarize the process that led to the creation of this new valve and report on the first implant's feasibility and first impression. The mitris valve has an overall implantability profile, overlapping the previous generation with no added challenges, but compared to the PERIMOUNT Magna Mitral Ease valve, the mitris valve boasts a more pliable saddle-shaped sewing cuff that is specifically tailored to fit the complex structure of the mitral valve with a lower stent height. This could be particularly beneficial in the context of double-valve replacement, as it may prevent any disturbance to the bioprosthesis located in the aortic position in small annulus. This could also prevent some rare but unpleasant complications such as left ventricle outflow obstruction or rupture of the atrioventricular sulcus. In addition, it could allow for better adherence to the saddle-shaped annulus of the mitral valve with the possibility of less stress (and therefore fibrosis) on the valve tissue, while further reducing the degeneration time. Furthermore, thanks to the possibility of being temporarily adjusted inwards, it is possible to ensure greater implantability compared to the previous generation of Magna Edwards mitral valves. Thanks to INSPIRIS technology, which prevents the generation of free aldehydes that promote oxidation and calcification of pericardial tissue, it is possible to assume that the durability will probably also improve. This reinforces the trustworthiness of the mitris valve.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Mitris RESILIA 阀门:久经考验的设计的新表皮。
Mitris 瓣膜融合了 Carpentier-Edwards PERIMOUNT Magna 二尖瓣轻松瓣膜(Edwards Lifesciences 公司,加利福尼亚州欧文市)和 INSPIRIS RESILIA 组织(Edwards Lifesciences 公司,加利福尼亚州欧文市)的最佳特点,继承了前者显著的血液动力学性能和后者耐用性的优点。在本文中,我们将总结这种新型瓣膜的诞生过程,并报告首次植入的可行性和第一印象。与 PERIMOUNT Magna 二尖瓣轻松瓣膜相比,mitris 瓣膜的马鞍形缝合袖带更加柔韧,专门针对二尖瓣的复杂结构定制,支架高度更低。这对双瓣置换尤其有利,因为它可以防止位于主动脉位置小瓣环中的生物假体受到任何干扰。这还可以避免一些罕见但令人不快的并发症,如左心室流出道阻塞或房室沟破裂。此外,它还能更好地附着在二尖瓣鞍形瓣环上,减少对瓣膜组织的压力(从而减少纤维化),同时进一步缩短退化时间。此外,与上一代 Magna Edwards 二尖瓣相比,由于可以临时向内调整,因此可以确保更高的植入性。INSPIRIS 技术可防止产生促进心包组织氧化和钙化的游离醛,因此可以认为其耐用性也将得到改善。这进一步增强了 mitris 瓣膜的可靠性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.00
自引率
0.00%
发文量
141
期刊最新文献
Robotic Assisted Lapendoscopic Single-Site Surgery for Ileal Deep Endometriosis. A Case Report and Review of Literature. Robotic versus Laparoscopic Partial Nephrectomy: A Systematic Review and Meta-Analysis of Randomised Trials. Cardiophrenic Lymph Node Resection Through Abdominal Subxiphoid Approach: Surgical Technique. What Happens to Endometriosis During the Menstrual Cycle? Robotic Total Knee Arthroplasty is Associated with Thinner and Less Constrained Polyethylene Inserts.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1