A modular, isolated high-voltage switch for application in ion mobility spectrometry

IF 2 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC HardwareX Pub Date : 2024-09-01 DOI:10.1016/j.ohx.2024.e00574
Martin Lippmann, Moritz Hitzemann, Jonas Winkelholz, David Bailey, Stefan Zimmermann
{"title":"A modular, isolated high-voltage switch for application in ion mobility spectrometry","authors":"Martin Lippmann,&nbsp;Moritz Hitzemann,&nbsp;Jonas Winkelholz,&nbsp;David Bailey,&nbsp;Stefan Zimmermann","doi":"10.1016/j.ohx.2024.e00574","DOIUrl":null,"url":null,"abstract":"<div><p>Ion mobility spectrometry is an emerging technology in trace gas analysis that has moved from typical safety and security applications to many other fields ranging from environmental and food quality monitoring to medicine and life sciences. Nevertheless, further dissemination, including the development of new instruments and the expansion into new fields of application requires the availability of the fundamental components of ion mobility spectrometers. For example, the electronics is essential for the analytical performance, but is only provided by specialized manufacturers due to specific requirements. In this paper, we present a modular, isolated high-voltage switch that can be operated at an isolated potential. The modular design enables tailoring its configuration to the required application. Each module can switch a voltage of up to 3 kV, and can be operated with an offset voltage of up to 7 kV. The switch has rise and fall times of less than 25 ns, making it suitable for a wide range of applications, e.g., in ion mobility spectrometry. Finally, the presented modular, isolated high-voltage switch was used in a push–pull configuration to generate the injection pulse of the ion gate. The new modular, isolated high-voltage switch shows similar performance compared to a commercially available high-voltage switch.</p></div>","PeriodicalId":37503,"journal":{"name":"HardwareX","volume":null,"pages":null},"PeriodicalIF":2.0000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2468067224000683/pdfft?md5=c0b7647745783914fcf83f5f4a8efb0d&pid=1-s2.0-S2468067224000683-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"HardwareX","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2468067224000683","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Ion mobility spectrometry is an emerging technology in trace gas analysis that has moved from typical safety and security applications to many other fields ranging from environmental and food quality monitoring to medicine and life sciences. Nevertheless, further dissemination, including the development of new instruments and the expansion into new fields of application requires the availability of the fundamental components of ion mobility spectrometers. For example, the electronics is essential for the analytical performance, but is only provided by specialized manufacturers due to specific requirements. In this paper, we present a modular, isolated high-voltage switch that can be operated at an isolated potential. The modular design enables tailoring its configuration to the required application. Each module can switch a voltage of up to 3 kV, and can be operated with an offset voltage of up to 7 kV. The switch has rise and fall times of less than 25 ns, making it suitable for a wide range of applications, e.g., in ion mobility spectrometry. Finally, the presented modular, isolated high-voltage switch was used in a push–pull configuration to generate the injection pulse of the ion gate. The new modular, isolated high-voltage switch shows similar performance compared to a commercially available high-voltage switch.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
应用于离子迁移谱仪的模块化隔离高压开关
离子迁移谱法是痕量气体分析领域的一项新兴技术,其应用已从典型的安全和安保领域扩展到从环境和食品质量监测到医学和生命科学等许多其他领域。然而,要进一步推广,包括开发新仪器和扩展到新的应用领域,就必须具备离子迁移谱仪的基本组件。例如,电子元件对分析性能至关重要,但由于特殊要求,只有专业制造商才能提供。在本文中,我们介绍了一种可在隔离电位下操作的模块化隔离高压开关。模块化设计使其能够根据所需应用进行定制配置。每个模块可切换高达 3 kV 的电压,并可在高达 7 kV 的偏移电压下运行。开关的上升和下降时间小于 25 ns,因此适用于广泛的应用,例如离子迁移率光谱分析。最后,所介绍的模块化隔离高压开关被用于推挽式配置,以产生离子闸门的注入脉冲。与市场上销售的高压开关相比,新型模块化隔离高压开关显示出相似的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
HardwareX
HardwareX Engineering-Industrial and Manufacturing Engineering
CiteScore
4.10
自引率
18.20%
发文量
124
审稿时长
24 weeks
期刊介绍: HardwareX is an open access journal established to promote free and open source designing, building and customizing of scientific infrastructure (hardware). HardwareX aims to recognize researchers for the time and effort in developing scientific infrastructure while providing end-users with sufficient information to replicate and validate the advances presented. HardwareX is open to input from all scientific, technological and medical disciplines. Scientific infrastructure will be interpreted in the broadest sense. Including hardware modifications to existing infrastructure, sensors and tools that perform measurements and other functions outside of the traditional lab setting (such as wearables, air/water quality sensors, and low cost alternatives to existing tools), and the creation of wholly new tools for either standard or novel laboratory tasks. Authors are encouraged to submit hardware developments that address all aspects of science, not only the final measurement, for example, enhancements in sample preparation and handling, user safety, and quality control. The use of distributed digital manufacturing strategies (e.g. 3-D printing) is encouraged. All designs must be submitted under an open hardware license.
期刊最新文献
An open source isolated data acquisition with trigger pulse generation for ion mobility spectrometry A 3D-Printable smartphone accessory for plant leaf chlorophyll measurement ASMI: An automated, low-cost indenter for soft matter A multispectral camera in the VIS–NIR equipped with thermal imaging and environmental sensors for non invasive analysis in precision agriculture MoMa: An assistive mobile manipulator with a webcam-based gaze control system
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1