Validation Experiments for In Situ Ne Isotope Analysis on Mars: Gas Separation Flange Assembly Using Polyimide Membrane and Metal Seal

IF 3.8 Q2 ASTRONOMY & ASTROPHYSICS The Planetary Science Journal Pub Date : 2024-08-28 DOI:10.3847/psj/ad66ba
Yuichiro Cho, Yayoi N. Miura, Hikaru Hyuga, Kenta Shimokoshi, Kazuo Yoshioka, Hiroyuki Kurokawa, Hidenori Kumagai, Naoyoshi Iwata, Satoshi Kasahara, Haruhisa Tabata, Mari Aida, Yoshifumi Saito, Seiji Sugita
{"title":"Validation Experiments for In Situ Ne Isotope Analysis on Mars: Gas Separation Flange Assembly Using Polyimide Membrane and Metal Seal","authors":"Yuichiro Cho, Yayoi N. Miura, Hikaru Hyuga, Kenta Shimokoshi, Kazuo Yoshioka, Hiroyuki Kurokawa, Hidenori Kumagai, Naoyoshi Iwata, Satoshi Kasahara, Haruhisa Tabata, Mari Aida, Yoshifumi Saito, Seiji Sugita","doi":"10.3847/psj/ad66ba","DOIUrl":null,"url":null,"abstract":"The Martian atmospheric Ne may reflect recent gas supply from its mantle via volcanic degassing, due to its short (∼100 Myr) escape timescale. The isotopic ratio of the Martian atmospheric Ne would therefore provide insights into that of the Martian mantle, further suggesting the origin of Mars volatiles during planetary formation. Mass spectrometric analysis of the Martian atmospheric Ne, however, has faced challenges from interference between <sup>20</sup>Ne<sup>+</sup> and <sup>40</sup>Ar<sup>++</sup>. Previous studies using a polyimide membrane for <sup>20</sup>Ne/<sup>40</sup>Ar separation were limited by the drawbacks of elastomeric O-rings to support the membrane, such as low-temperature intolerance, outgassing, and the need to endure environmental conditions during the launch and before/after landing on Mars. This study proposes a new method employing a metal C-ring to secure a 100 <italic toggle=\"yes\">μ</italic>m polyimide sheet within vacuum flanges. Environmental tests, including vibration, shock, extreme temperatures, and radiation exposure, were conducted on the gas separation flanges. Pre- and post-test analyses for He, Ne, and Ar demonstrated the membrane-flange system’s resilience. Gas permeation measurements using terrestrial air effectively permeated <sup>4</sup>He and <sup>20</sup>Ne, while reducing <sup>40</sup>Ar by more than six orders of magnitude. This study achieved a &lt;3% accuracy in determining the <sup>20</sup>Ne/<sup>22</sup>Ne ratio, sufficient for assessing the origins of Ne in the Martian mantle. Furthermore, experiments with a 590 Pa gas mixture simulating the Martian atmosphere achieved a 10% accuracy for the <sup>20</sup>Ne/<sup>22</sup>Ne isotope ratio, with gas abundances consistent with numerical predictions based on individual partial pressures. These results validate the suitability of the developed polyimide membrane assembly for in situ Martian Ne analyses.","PeriodicalId":34524,"journal":{"name":"The Planetary Science Journal","volume":"26 1","pages":""},"PeriodicalIF":3.8000,"publicationDate":"2024-08-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Planetary Science Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3847/psj/ad66ba","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ASTRONOMY & ASTROPHYSICS","Score":null,"Total":0}
引用次数: 0

Abstract

The Martian atmospheric Ne may reflect recent gas supply from its mantle via volcanic degassing, due to its short (∼100 Myr) escape timescale. The isotopic ratio of the Martian atmospheric Ne would therefore provide insights into that of the Martian mantle, further suggesting the origin of Mars volatiles during planetary formation. Mass spectrometric analysis of the Martian atmospheric Ne, however, has faced challenges from interference between 20Ne+ and 40Ar++. Previous studies using a polyimide membrane for 20Ne/40Ar separation were limited by the drawbacks of elastomeric O-rings to support the membrane, such as low-temperature intolerance, outgassing, and the need to endure environmental conditions during the launch and before/after landing on Mars. This study proposes a new method employing a metal C-ring to secure a 100 μm polyimide sheet within vacuum flanges. Environmental tests, including vibration, shock, extreme temperatures, and radiation exposure, were conducted on the gas separation flanges. Pre- and post-test analyses for He, Ne, and Ar demonstrated the membrane-flange system’s resilience. Gas permeation measurements using terrestrial air effectively permeated 4He and 20Ne, while reducing 40Ar by more than six orders of magnitude. This study achieved a <3% accuracy in determining the 20Ne/22Ne ratio, sufficient for assessing the origins of Ne in the Martian mantle. Furthermore, experiments with a 590 Pa gas mixture simulating the Martian atmosphere achieved a 10% accuracy for the 20Ne/22Ne isotope ratio, with gas abundances consistent with numerical predictions based on individual partial pressures. These results validate the suitability of the developed polyimide membrane assembly for in situ Martian Ne analyses.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
火星现场 Ne 同位素分析验证实验:使用聚酰亚胺膜和金属密封件的气体分离法兰组件
火星大气中的 "氖 "可能反映了最近通过火山脱气从火星地幔中获得的气体,因为 "氖 "的逃逸时间很短(100 Myr)。因此,火星大气中氖的同位素比值将有助于了解火星地幔的同位素比值,进一步说明火星挥发物在行星形成过程中的来源。然而,火星大气中 Ne 的质谱分析面临着 20Ne+ 和 40Ar++ 之间干扰的挑战。以前使用聚酰亚胺膜来分离 20Ne/40Ar 的研究受到了支撑膜的弹性 O 形环的缺点的限制,如不耐低温、排气,以及在发射过程中和登陆火星前后需要承受环境条件等。本研究提出了一种采用金属 C 形环将 100 μm 聚酰亚胺薄膜固定在真空法兰内的新方法。对气体分离法兰进行了环境测试,包括振动、冲击、极端温度和辐射暴露。对 He、Ne 和 Ar 进行的试验前和试验后分析表明,膜-法兰系统具有良好的适应性。使用陆地空气进行的气体渗透测量有效地渗透了 4He 和 20Ne,同时将 40Ar 减少了六个数量级以上。这项研究在确定20Ne/22Ne比率方面达到了<3%的精确度,足以评估火星地幔中Ne的来源。此外,使用模拟火星大气的 590 Pa 气体混合物进行的实验使 20Ne/22Ne 同位素比值的精确度达到了 10%,气体丰度与基于单个分压的数值预测一致。这些结果验证了所开发的聚酰亚胺膜组件适用于原位火星氖分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
The Planetary Science Journal
The Planetary Science Journal Earth and Planetary Sciences-Geophysics
CiteScore
5.20
自引率
0.00%
发文量
249
审稿时长
15 weeks
期刊最新文献
Jovian Vortex Hunter: A Citizen Science Project to Study Jupiter’s Vortices Experimental Method for Measuring Cohesion of Regolith via Electrostatic Lofting Mid-infrared Measurements of Ion-irradiated Carbonaceous Meteorites: How to Better Detect Space Weathering Effects Triton’s Captured Youth: Tidal Heating Kept Triton Warm and Active for Billions of Years The Global Distribution of Water and Hydroxyl on the Moon as Seen by the Moon Mineralogy Mapper (M3)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1