Tensile testing in feline ventral abdominal coeliotomy closure with different sizes of polydioxanone suture material: a biomechanical study

IF 1.9 2区 农林科学 Q2 VETERINARY SCIENCES Journal of Feline Medicine and Surgery Pub Date : 2024-09-17 DOI:10.1177/1098612x241271871
Sebastian Jaenich, Tomasz Bartkowiak, Hubert Jopek, Mathias Brunnberg, Pavel Slunsky
{"title":"Tensile testing in feline ventral abdominal coeliotomy closure with different sizes of polydioxanone suture material: a biomechanical study","authors":"Sebastian Jaenich, Tomasz Bartkowiak, Hubert Jopek, Mathias Brunnberg, Pavel Slunsky","doi":"10.1177/1098612x241271871","DOIUrl":null,"url":null,"abstract":"ObjectivesThe aim of this study was to evaluate, in vitro, the load and type of failure of the sutured ventral abdominal fascia of cats with different sizes of suture material made of polydioxanone (PDX) (2-0, 3-0, 4-0, 5-0 USP).MethodsA total of 32 samples of the ventral abdominal wall from 16 cadaveric cats were harvested using an hourglass-shaped template. The samples were sectioned longitudinally along the linea alba and then sutured together in a continuous pattern using four different randomly assigned sizes of pdx suture material (2-0, 3-0, 4-0, 5-0 USP). A universal testing machine was used for linear distraction of the samples. The tensile strength and type of failure were recorded and analysed. Three types of failure were defined: suture material failure (S), suture line failure (T1) and failure of the abdominal wall further away from the linea alba (T2).ResultsThe frequency of suture material failure decreased with increasing suture size. Suture size 5-0 failed due to a S failure in 6/8 samples, PDX 4-0 failed in 2/8 samples and PDX 3-0 failed in only 1/8 samples. However, PDX 2-0 failed due to only T1 or T2 failures, with both failures being almost equally represented. No statistically significant differences in the load to failure between PDX 2-0, 3-0 and 4-0 were noted ( P >0.05). The risk of suture failure increased with decreasing suture size diameter.Conclusions and relevancePDX 2-0 and 3-0 can be used without reservation for the closure of ventral midline coeliotomy in cats. Although there was no statistically significant difference between PDX 2-0, 3-0 and 4-0, PDX 4-0 showed a higher probability for suture breakage and should be used only after careful consideration of the patient while clinical evaluation is pending. Pdx 5-0 cannot be recommended as a safe suture size for this type of surgical closure.","PeriodicalId":15851,"journal":{"name":"Journal of Feline Medicine and Surgery","volume":"29 1","pages":""},"PeriodicalIF":1.9000,"publicationDate":"2024-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Feline Medicine and Surgery","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1177/1098612x241271871","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

ObjectivesThe aim of this study was to evaluate, in vitro, the load and type of failure of the sutured ventral abdominal fascia of cats with different sizes of suture material made of polydioxanone (PDX) (2-0, 3-0, 4-0, 5-0 USP).MethodsA total of 32 samples of the ventral abdominal wall from 16 cadaveric cats were harvested using an hourglass-shaped template. The samples were sectioned longitudinally along the linea alba and then sutured together in a continuous pattern using four different randomly assigned sizes of pdx suture material (2-0, 3-0, 4-0, 5-0 USP). A universal testing machine was used for linear distraction of the samples. The tensile strength and type of failure were recorded and analysed. Three types of failure were defined: suture material failure (S), suture line failure (T1) and failure of the abdominal wall further away from the linea alba (T2).ResultsThe frequency of suture material failure decreased with increasing suture size. Suture size 5-0 failed due to a S failure in 6/8 samples, PDX 4-0 failed in 2/8 samples and PDX 3-0 failed in only 1/8 samples. However, PDX 2-0 failed due to only T1 or T2 failures, with both failures being almost equally represented. No statistically significant differences in the load to failure between PDX 2-0, 3-0 and 4-0 were noted ( P >0.05). The risk of suture failure increased with decreasing suture size diameter.Conclusions and relevancePDX 2-0 and 3-0 can be used without reservation for the closure of ventral midline coeliotomy in cats. Although there was no statistically significant difference between PDX 2-0, 3-0 and 4-0, PDX 4-0 showed a higher probability for suture breakage and should be used only after careful consideration of the patient while clinical evaluation is pending. Pdx 5-0 cannot be recommended as a safe suture size for this type of surgical closure.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用不同尺寸的聚二氧杂蒽酮缝合材料进行猫腹部开腹缝合的拉力测试:一项生物力学研究
本研究的目的是在体外评估使用不同尺寸的聚二氧杂蒽酮(PDX)(2-0、3-0、4-0、5-0 USP)缝合猫腹部筋膜的负荷和失败类型。沿白线对样本进行纵向切片,然后使用随机分配的四种不同规格的 pdx 缝合材料(2-0、3-0、4-0、5-0 USP)以连续的模式缝合在一起。使用万能试验机对样本进行线性牵拉。对拉伸强度和失效类型进行了记录和分析。结果缝合材料失效的频率随着缝合线尺寸的增加而降低。6/8 个样本的 5-0 号缝合线因 S 型失败而失败,2/8 个样本的 PDX 4-0 号缝合线因 S 型失败而失败,仅 1/8 个样本的 PDX 3-0 号缝合线因 S 型失败而失败。然而,PDX 2-0 仅因 T1 或 T2 故障而失效,这两种故障几乎各占一半。PDX 2-0、3-0 和 4-0 之间的失效载荷差异无统计学意义(P >0.05)。结论和意义PDX 2-0 和 3-0 可以毫无保留地用于猫腹中线联合开腹术的缝合。虽然 PDX 2-0、3-0 和 4-0 在统计学上没有显著差异,但 PDX 4-0 显示出较高的缝线断裂几率,应在临床评估前对患者进行慎重考虑后再使用。Pdx 5-0 不能被推荐为此类手术缝合的安全缝合线尺寸。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.90
自引率
17.60%
发文量
254
审稿时长
8-16 weeks
期刊介绍: JFMS is an international, peer-reviewed journal aimed at both practitioners and researchers with an interest in the clinical veterinary healthcare of domestic cats. The journal is published monthly in two formats: ‘Classic’ editions containing high-quality original papers on all aspects of feline medicine and surgery, including basic research relevant to clinical practice; and dedicated ‘Clinical Practice’ editions primarily containing opinionated review articles providing state-of-the-art information for feline clinicians, along with other relevant articles such as consensus guidelines.
期刊最新文献
Doxycycline with or without famciclovir for infectious ophthalmic and respiratory disease: a prospective, randomized, masked, placebo-controlled trial in 373 kittens. Evaluation of cats treated with robenacoxib after gastrointestinal surgery. Serological and molecular detection of Toxoplasma gondii in cats in Europe with evaluation of associated risk factors for pathogen contact/infection. Nasopharyngeal stenosis in cats: a retrospective study of 21 cases comparing endoscopic and surgical treatment (2018-2022). Risk factors affecting all-cause mortality in cats hospitalized by a referral soft tissue service.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1