Exploring 3D Printed Implants With Anti-Dropout Function to Overcome Time Constraints in Acute Orbital Fractures for Patient-Specific Implants.

IF 1 4区 医学 Q3 SURGERY Journal of Craniofacial Surgery Pub Date : 2024-09-16 DOI:10.1097/SCS.0000000000010647
Dong Ha Park, Jun Suk Lee, Yeon Kyo Jung, Hyoseob Lim
{"title":"Exploring 3D Printed Implants With Anti-Dropout Function to Overcome Time Constraints in Acute Orbital Fractures for Patient-Specific Implants.","authors":"Dong Ha Park, Jun Suk Lee, Yeon Kyo Jung, Hyoseob Lim","doi":"10.1097/SCS.0000000000010647","DOIUrl":null,"url":null,"abstract":"<p><p>Orbital wall reconstruction and implant insertion are crucial procedures for temporarily replacing the orbital walls in cases of significant fractures. Traditional methods using planar orbital implants have faced challenges owing to their flat shape, which increases the risk of dislocation from improper cuts and necessitates the use of screws in the orbital rim. This study aims to improve outcomes by employing customized 3-dimensional implants, thereby reducing complications and risk of dislocation resulting from external shock or implant weight postinsertion. This prospective study included 12 Korean individuals diagnosed with facial fractures (orbital wall injuries). Surgeries were performed on 12 patients, and follow-up CT scans were conducted on 10 of them. Therefore, the authors could only address the results for the 10 patients. The authors used bioactive glass ceramics and medical-grade poly-e-caprolactone to 3D print personalized implants, completing the manufacturing process in an average of 4.6 days. Computed tomography scans guided measurements of orbital volumes and exophthalmos. After surgery, we found that the difference values for bone orbital volumes (<0.1 mL) and exophthalmos (<1 mm except one) decreased compared with presurgery values. Independent t tests and Pearson correlation analysis revealed no significant changes between normal and affected sides in both phases. However, R-values increased in the postsurgery phase. Patients monitored postsurgery at 2 weeks, 3 months, and 6 months showed no complications. The 3D-printed patient-specific implants, customized to individual fracture shapes and featuring distinct implants and locking parts with notches, effectively restore bony orbital volumes and reduce exophthalmos. They have been proven feasible and applicable for reconstructing acute orbital wall fractures.</p>","PeriodicalId":15462,"journal":{"name":"Journal of Craniofacial Surgery","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2024-09-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Craniofacial Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/SCS.0000000000010647","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Orbital wall reconstruction and implant insertion are crucial procedures for temporarily replacing the orbital walls in cases of significant fractures. Traditional methods using planar orbital implants have faced challenges owing to their flat shape, which increases the risk of dislocation from improper cuts and necessitates the use of screws in the orbital rim. This study aims to improve outcomes by employing customized 3-dimensional implants, thereby reducing complications and risk of dislocation resulting from external shock or implant weight postinsertion. This prospective study included 12 Korean individuals diagnosed with facial fractures (orbital wall injuries). Surgeries were performed on 12 patients, and follow-up CT scans were conducted on 10 of them. Therefore, the authors could only address the results for the 10 patients. The authors used bioactive glass ceramics and medical-grade poly-e-caprolactone to 3D print personalized implants, completing the manufacturing process in an average of 4.6 days. Computed tomography scans guided measurements of orbital volumes and exophthalmos. After surgery, we found that the difference values for bone orbital volumes (<0.1 mL) and exophthalmos (<1 mm except one) decreased compared with presurgery values. Independent t tests and Pearson correlation analysis revealed no significant changes between normal and affected sides in both phases. However, R-values increased in the postsurgery phase. Patients monitored postsurgery at 2 weeks, 3 months, and 6 months showed no complications. The 3D-printed patient-specific implants, customized to individual fracture shapes and featuring distinct implants and locking parts with notches, effectively restore bony orbital volumes and reduce exophthalmos. They have been proven feasible and applicable for reconstructing acute orbital wall fractures.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
探索具有防脱落功能的 3D 打印植入物,以克服急性眼眶骨折患者特定植入物的时间限制。
眶壁重建和植入物植入是在严重骨折情况下临时替代眶壁的关键程序。使用平面眶内植入物的传统方法因其扁平形状而面临挑战,这增加了因切割不当而脱位的风险,并且必须在眶缘使用螺钉。本研究旨在通过采用定制的三维植入物来改善治疗效果,从而减少外力冲击或植入物重量导致的并发症和脱位风险。这项前瞻性研究纳入了 12 名被诊断为面部骨折(眶壁损伤)的韩国人。对 12 名患者进行了手术,并对其中 10 名患者进行了后续 CT 扫描。因此,作者只能对这 10 名患者的结果进行分析。作者使用生物活性玻璃陶瓷和医用级聚己内酯三维打印个性化植入物,平均在 4.6 天内完成制造过程。计算机断层扫描引导测量了眼眶体积和眼球外凸。手术后,我们发现骨眶体积的差异值 (
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.70
自引率
11.10%
发文量
968
审稿时长
1.5 months
期刊介绍: ​The Journal of Craniofacial Surgery serves as a forum of communication for all those involved in craniofacial surgery, maxillofacial surgery and pediatric plastic surgery. Coverage ranges from practical aspects of craniofacial surgery to the basic science that underlies surgical practice. The journal publishes original articles, scientific reviews, editorials and invited commentary, abstracts and selected articles from international journals, and occasional international bibliographies in craniofacial surgery.
期刊最新文献
Determining Chin Dimensions for Feminizing Genioplasty: An Anatomic Study. Immediately Injections of Botulinum Toxin A After Surgical Excision for Ear Keloids: A Retrospective Study. Is Artificial Intelligence a Useful Tool for Clinical Practice of Oral and Maxillofacial Surgery? A Patient With Cryptococcal Meningitis Accompanied With Acute Intracranial Hypertension Treated by Ventricular Abdominal-wall Drainage. Improvement of the Facial and Dental Esthetics With Surgery-Only Approach.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1