Diagnostic accuracy of microvascular flow imaging ultrasound for endoleak detection after endovascular aortic aneurysm repair: a systematic review and meta-analysis.

Polish journal of radiology Pub Date : 2024-08-22 eCollection Date: 2024-01-01 DOI:10.5114/pjr/190502
Marcin Czeczelewski, Ewa Kopyto, Maryla Kuczyńska, Anna Drelich-Zbroja, Tomasz Jargiełło
{"title":"Diagnostic accuracy of microvascular flow imaging ultrasound for endoleak detection after endovascular aortic aneurysm repair: a systematic review and meta-analysis.","authors":"Marcin Czeczelewski, Ewa Kopyto, Maryla Kuczyńska, Anna Drelich-Zbroja, Tomasz Jargiełło","doi":"10.5114/pjr/190502","DOIUrl":null,"url":null,"abstract":"<p><p>The objective was to assess the diagnostic accuracy of microvascular flow imaging ultrasound (MVUS) for the detection of endoleak after endovascular aortic aneurysm repair. A systematic search of the literature published until January 2024 was performed according to the Preferred Reporting Items for Systematic reviews and Meta-Analyses of Diagnostic Test Accuracy (PRISMA-DTA) guidelines. The pooled rates of sensitivity, specificity, and diagnostic odds ratio of MVUS in endoleak detection with computed tomography angiography as the reference standard were estimated using univariate random-effect analysis with 95% confidence intervals. Three studies were considered eligible for inclusion. Superb micro-vascular imaging (SMI) was used as an MVUS technique in all cases. The total number of paired scans was 209. Sensitivity and specificity of the individual studies ranged 0.75-1.00 and 0.93-1.00, respectively. Pooled sensitivity and specificity of the SMI method was 0.91 (CI: 0.82-0.96) and 0.98 (CI: 0.94-1.00), respectively. The pooled diagnostic odds ratio was 635 (95% CI: 128-3140). The findings of the present study support the use of the MVUS for endoleak detection. However, further research is warranted to explore the broader application of MVUS, providing a more comprehensive understanding and establishing robust criteria for its role in clinical practice.</p>","PeriodicalId":94174,"journal":{"name":"Polish journal of radiology","volume":"89 ","pages":"e414-e419"},"PeriodicalIF":0.0000,"publicationDate":"2024-08-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11384215/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Polish journal of radiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5114/pjr/190502","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The objective was to assess the diagnostic accuracy of microvascular flow imaging ultrasound (MVUS) for the detection of endoleak after endovascular aortic aneurysm repair. A systematic search of the literature published until January 2024 was performed according to the Preferred Reporting Items for Systematic reviews and Meta-Analyses of Diagnostic Test Accuracy (PRISMA-DTA) guidelines. The pooled rates of sensitivity, specificity, and diagnostic odds ratio of MVUS in endoleak detection with computed tomography angiography as the reference standard were estimated using univariate random-effect analysis with 95% confidence intervals. Three studies were considered eligible for inclusion. Superb micro-vascular imaging (SMI) was used as an MVUS technique in all cases. The total number of paired scans was 209. Sensitivity and specificity of the individual studies ranged 0.75-1.00 and 0.93-1.00, respectively. Pooled sensitivity and specificity of the SMI method was 0.91 (CI: 0.82-0.96) and 0.98 (CI: 0.94-1.00), respectively. The pooled diagnostic odds ratio was 635 (95% CI: 128-3140). The findings of the present study support the use of the MVUS for endoleak detection. However, further research is warranted to explore the broader application of MVUS, providing a more comprehensive understanding and establishing robust criteria for its role in clinical practice.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
血管内主动脉瘤修补术后微血管血流成像超声检测内漏的诊断准确性:系统综述和荟萃分析。
目的是评估微血管血流成像超声(MVUS)在血管内主动脉瘤修复术后检测内漏的诊断准确性。根据系统综述和诊断测试准确性荟萃分析首选报告项目(PRISMA-DTA)指南,对2024年1月之前发表的文献进行了系统检索。以计算机断层扫描血管造影作为参考标准,采用单变量随机效应分析和 95% 置信区间估算了 MVUS 在内膜渗漏检测中的敏感性、特异性和诊断几率比的汇总率。有三项研究符合纳入条件。所有病例均采用超微血管成像(SMI)作为 MVUS 技术。配对扫描的总次数为 209 次。单项研究的敏感性和特异性分别为 0.75-1.00 和 0.93-1.00。SMI方法的汇总敏感性和特异性分别为0.91(CI:0.82-0.96)和0.98(CI:0.94-1.00)。汇总诊断几率比为 635(95% CI:128-3140)。本研究结果支持使用 MVUS 检测内漏。然而,还需要进一步的研究来探索 MVUS 的更广泛应用,为其在临床实践中的作用提供更全面的理解并建立健全的标准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.10
自引率
0.00%
发文量
0
期刊最新文献
Comments on data balance, test-set accounting, and thresholded reporting in an adaptive convolution neural network model for tuberculosis detection and diagnosis using semantic segmentation. Volumetric differences in the brain in children with hypoxic-ischemic encephalopathy after therapeutic hypothermia: a review of MRI findings. Prognostic value of collateral scoring systems for hemorrhagic transformation after endovascular treatment in acute ischemic stroke. Impact of breast implant presence and type on mean glandular dose calculations. Distribution, extent, and calculated age of initiation of coronary artery calcification.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1