Biomechanical analysis of cadaveric wrists before and after MOTEC wrist arthroplasty using a hexapod robot.

Gregory I Bain, Simon F Bellringer, Michael P Russo, Dhara Amin, John J Costi
{"title":"Biomechanical analysis of cadaveric wrists before and after MOTEC wrist arthroplasty using a hexapod robot.","authors":"Gregory I Bain, Simon F Bellringer, Michael P Russo, Dhara Amin, John J Costi","doi":"10.1177/17531934241274135","DOIUrl":null,"url":null,"abstract":"<p><p>This study compares wrist motion, biomechanical behaviour and radiographic parameters before and after total wrist arthroplasty using a fourth-generation spherical articulation prosthesis. A total of 10 cadaveric specimens were assessed using a hexapod Stewart platform robot. After arthroplasty, there were significant increases in both stiffness and phase angle of wrist motion across all planes of motion assessed. In three specimens, a sudden increase in moment was observed on load/displacement curves. Radiographically, carpal height increased by 14%, and the centre of rotation was displaced 11.1 mm proximally, 4.6 mm dorsally and 3.9 mm radially. This stretched the musculotendinous units, tightening the joint, while increasing the moment arm of the wrist flexors and decreasing the moment arm of the extensors, potentially important in the development of postoperative flexion contractures. Possible alterations in technique and/or implant design are considered to assist surgeons in achieving optimal clinical and survivorship outcomes.</p>","PeriodicalId":94237,"journal":{"name":"The Journal of hand surgery, European volume","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-09-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of hand surgery, European volume","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/17531934241274135","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This study compares wrist motion, biomechanical behaviour and radiographic parameters before and after total wrist arthroplasty using a fourth-generation spherical articulation prosthesis. A total of 10 cadaveric specimens were assessed using a hexapod Stewart platform robot. After arthroplasty, there were significant increases in both stiffness and phase angle of wrist motion across all planes of motion assessed. In three specimens, a sudden increase in moment was observed on load/displacement curves. Radiographically, carpal height increased by 14%, and the centre of rotation was displaced 11.1 mm proximally, 4.6 mm dorsally and 3.9 mm radially. This stretched the musculotendinous units, tightening the joint, while increasing the moment arm of the wrist flexors and decreasing the moment arm of the extensors, potentially important in the development of postoperative flexion contractures. Possible alterations in technique and/or implant design are considered to assist surgeons in achieving optimal clinical and survivorship outcomes.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用六足机器人对 MOTEC 腕关节置换术前后的尸体腕部进行生物力学分析。
这项研究比较了使用第四代球形关节假体进行全腕关节置换术前后的腕关节运动、生物力学行为和放射学参数。使用六足 Stewart 平台机器人对 10 具尸体标本进行了评估。关节置换术后,在所有评估的运动平面上,腕关节运动的硬度和相位角都有显著增加。在三个标本中,观察到载荷/位移曲线上的力矩突然增加。从影像学角度看,腕骨高度增加了 14%,旋转中心向近端移动了 11.1 毫米,向背移动了 4.6 毫米,向径向移动了 3.9 毫米。这拉伸了肌肉腱膜单元,收紧了关节,同时增加了腕关节屈肌的力矩臂,减少了腕关节伸肌的力矩臂,可能对术后屈曲挛缩的发生有重要影响。考虑对技术和/或植入物设计进行可能的改变,以帮助外科医生获得最佳的临床和存活效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Guideline on managing thumb ulnar collateral ligament injuries: the British Society of Surgery for the Hand Evidence for Surgical Treatment (BEST) findings and recommendations. Is the ulnar fovea sign positive only in foveal tears of the triangular fibrocartilage complex? Biomechanical analysis of cadaveric wrists before and after MOTEC wrist arthroplasty using a hexapod robot. Wrist arthrodesis in flexed position combined with proximal row carpectomy and ostectomy of the distal radius for spastic patients. Misinformation about upper extremity conditions in guidelines for clinicians.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1