A case report of superficial femoral artery pseudoaneurysm caused by stent fracture

Liang Xie , Zhengdong Fang
{"title":"A case report of superficial femoral artery pseudoaneurysm caused by stent fracture","authors":"Liang Xie ,&nbsp;Zhengdong Fang","doi":"10.1016/j.avsurg.2024.100337","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><div>Developing pseudoaneurysms following stent fracture is a rare complication of stent implantation in patients with chronic lower limb ischemia. We presented a case of pseudoaneurysm secondary to a femoral artery stenting fracture in the left lower extremity, which was successfully managed with vascular intervention under local anesthesia and followed up for 36 months.</div></div><div><h3>Case Report</h3><div>An 80-year-old male with a history of hypertension and cerebral infarction presented with a mass in the left lower limb accompanied by swelling and pain. Doppler ultrasound revealed a pseudoaneurysm measuring 6 × 7 cm in the left superficial femoral artery. Subsequent digital subtraction angiography indicated a fracture of the original stent overlap and a ruptured pseudoaneurysm measuring 8 cm in diameter. Following intravenous heparin administration, a 7 × 150 mm self-expanding membrane-covered stent was successfully implanted to address this issue. Final angiography confirmed proper stent placement, exclusion of the aneurysm, and absence of internal leakage. No obstruction was observed in the sub patellar artery. The patient's symptoms gradually improved without requiring further surgical intervention. Oral aspirin and clopidogrel were administered for 36 months after surgery, and there was no recurrence of symptoms.</div></div><div><h3>Conclusion</h3><div>Active surgical intervention is the optimal treatment approach for patients with pseudoaneurysm caused by stent fracture, whereas endovascular therapy remains a dependable option for such scenarios. The crucial step in the procedure involved inserting the guidewire into both ends of the fractured stent to establish the operative pathway, followed by the introduction of the self-expanding covered stent and isolation of the aneurysm. This endeavor aimed to offer significant insights for treating similar conditions.</div></div>","PeriodicalId":72235,"journal":{"name":"Annals of vascular surgery. Brief reports and innovations","volume":"4 4","pages":"Article 100337"},"PeriodicalIF":0.0000,"publicationDate":"2024-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of vascular surgery. Brief reports and innovations","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2772687824000898","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

Developing pseudoaneurysms following stent fracture is a rare complication of stent implantation in patients with chronic lower limb ischemia. We presented a case of pseudoaneurysm secondary to a femoral artery stenting fracture in the left lower extremity, which was successfully managed with vascular intervention under local anesthesia and followed up for 36 months.

Case Report

An 80-year-old male with a history of hypertension and cerebral infarction presented with a mass in the left lower limb accompanied by swelling and pain. Doppler ultrasound revealed a pseudoaneurysm measuring 6 × 7 cm in the left superficial femoral artery. Subsequent digital subtraction angiography indicated a fracture of the original stent overlap and a ruptured pseudoaneurysm measuring 8 cm in diameter. Following intravenous heparin administration, a 7 × 150 mm self-expanding membrane-covered stent was successfully implanted to address this issue. Final angiography confirmed proper stent placement, exclusion of the aneurysm, and absence of internal leakage. No obstruction was observed in the sub patellar artery. The patient's symptoms gradually improved without requiring further surgical intervention. Oral aspirin and clopidogrel were administered for 36 months after surgery, and there was no recurrence of symptoms.

Conclusion

Active surgical intervention is the optimal treatment approach for patients with pseudoaneurysm caused by stent fracture, whereas endovascular therapy remains a dependable option for such scenarios. The crucial step in the procedure involved inserting the guidewire into both ends of the fractured stent to establish the operative pathway, followed by the introduction of the self-expanding covered stent and isolation of the aneurysm. This endeavor aimed to offer significant insights for treating similar conditions.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
支架断裂导致股浅动脉假性动脉瘤的病例报告
目的在慢性下肢缺血患者中,支架断裂后出现假性动脉瘤是一种罕见的支架植入并发症。我们报告了一例左下肢股动脉支架断裂继发假性动脉瘤的病例,该病例在局麻下通过血管介入治疗获得成功,并随访了 36 个月。病例报告 一位 80 岁的男性患者,有高血压和脑梗塞病史,因左下肢肿块伴肿胀和疼痛就诊。多普勒超声检查发现左股浅动脉有一个 6 × 7 厘米的假性动脉瘤。随后进行的数字减影血管造影显示,原支架重叠部分断裂,假动脉瘤破裂,直径达 8 厘米。静脉注射肝素后,成功植入了一个 7 × 150 毫米的自膨胀膜覆盖支架来解决这一问题。最终的血管造影证实支架放置正确,动脉瘤已被排除,并且没有内漏。髌下动脉未发现阻塞。患者的症状逐渐好转,无需进一步手术治疗。术后口服阿司匹林和氯吡格雷36个月,症状没有复发。结论对于支架断裂引起的假性动脉瘤患者,积极的外科干预是最佳治疗方法,而血管内治疗仍然是此类情况下的可靠选择。手术的关键步骤是将导丝插入断裂支架的两端以建立手术路径,然后引入自膨胀覆盖支架并分离动脉瘤。这项工作旨在为治疗类似病症提供重要启示。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
0.20
自引率
0.00%
发文量
0
审稿时长
62 days
期刊最新文献
Intravascular lipoma with extravascular extension, a rare phenomena and review of the literature Paget-Schroetter Syndrome secondary to anomalous right-sided aortic arch: A case report Facial flushing can be a rare presentation of SVC syndrome Initial experience and early outcomes of treatment of complex deep vein thrombosis with flowtriever and clottriever mechanical thrombectomy systems in conjunction with protrieve sheath A rare case of acute arterial thrombosis revealing undifferentiated arterial leiomyosarcoma
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1