Resolving studies of Balmer alpha lines relevant to the LIBS analysis of hydrogen isotope retention

IF 3.2 2区 化学 Q1 SPECTROSCOPY Spectrochimica Acta Part B: Atomic Spectroscopy Pub Date : 2024-09-21 DOI:10.1016/j.sab.2024.107050
I. Traparic , D. Rankovic , B.D. Stankov , J. Savovic , M. Kuzmanovic , M. Ivkovic
{"title":"Resolving studies of Balmer alpha lines relevant to the LIBS analysis of hydrogen isotope retention","authors":"I. Traparic ,&nbsp;D. Rankovic ,&nbsp;B.D. Stankov ,&nbsp;J. Savovic ,&nbsp;M. Kuzmanovic ,&nbsp;M. Ivkovic","doi":"10.1016/j.sab.2024.107050","DOIUrl":null,"url":null,"abstract":"<div><div>Utilizing Laser-Induced Breakdown Spectroscopy (LIBS) for detecting deuterium and tritium retention in fusion devices poses a significant challenge due to the experimental limitations in resolving hydrogen isotope Balmer alpha lines (H<sub>α</sub>, D<sub>α</sub>, and T<sub>α</sub>). This study utilizes the Rayleigh criterion to distinguish T<sub>α</sub> and D<sub>α</sub> lines by determining the maximum line widths and corresponding plasma parameters. Experimental validation was performed through LIBS analysis of heavy water-doped graphite/silica gel targets in both argon and helium atmospheres to assess the predicted plasma parameters and line profile shapes. The optimization of laser pulse energy, gas pressure, delay, and gate times aimed at achieving fully resolved lines based on the intensity, width, and the dip between deuterium and hydrogen Balmer alpha lines. By fine-tuning these experimental parameters, the study successfully achieved a dip of less than 10 % between the H<sub>α</sub> and D<sub>α</sub> lines with a satisfactory signal-to-noise ratio, demonstrating the feasibility of fully resolving the T<sub>α</sub> and D<sub>α</sub> lines. These findings underscore the potential of LIBS in enhancing the detection of deuterium and tritium retention in fusion devices.</div></div>","PeriodicalId":21890,"journal":{"name":"Spectrochimica Acta Part B: Atomic Spectroscopy","volume":"221 ","pages":"Article 107050"},"PeriodicalIF":3.2000,"publicationDate":"2024-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Spectrochimica Acta Part B: Atomic Spectroscopy","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0584854724001940","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"SPECTROSCOPY","Score":null,"Total":0}
引用次数: 0

Abstract

Utilizing Laser-Induced Breakdown Spectroscopy (LIBS) for detecting deuterium and tritium retention in fusion devices poses a significant challenge due to the experimental limitations in resolving hydrogen isotope Balmer alpha lines (Hα, Dα, and Tα). This study utilizes the Rayleigh criterion to distinguish Tα and Dα lines by determining the maximum line widths and corresponding plasma parameters. Experimental validation was performed through LIBS analysis of heavy water-doped graphite/silica gel targets in both argon and helium atmospheres to assess the predicted plasma parameters and line profile shapes. The optimization of laser pulse energy, gas pressure, delay, and gate times aimed at achieving fully resolved lines based on the intensity, width, and the dip between deuterium and hydrogen Balmer alpha lines. By fine-tuning these experimental parameters, the study successfully achieved a dip of less than 10 % between the Hα and Dα lines with a satisfactory signal-to-noise ratio, demonstrating the feasibility of fully resolving the Tα and Dα lines. These findings underscore the potential of LIBS in enhancing the detection of deuterium and tritium retention in fusion devices.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
与 LIBS 分析氢同位素保留相关的巴尔默阿尔法线的分辨研究
由于在分辨氢同位素巴尔默α线(Hα、Dα 和 Tα)方面存在实验限制,因此利用激光诱导击穿光谱(LIBS)来检测聚变装置中的氘和氚滞留是一项重大挑战。本研究通过确定最大线宽和相应的等离子体参数,利用瑞利准则来区分 Tα 和 Dα 线。通过在氩气和氦气气氛中对掺重水的石墨/硅胶靶进行 LIBS 分析,对预测的等离子体参数和线剖面形状进行了实验验证。优化激光脉冲能量、气体压力、延迟和栅极时间的目的是根据氘和氢巴尔默α线的强度、宽度和倾角实现完全解析的线。通过微调这些实验参数,研究成功地实现了 Hα 和 Dα 线之间小于 10 % 的倾角,信噪比令人满意,证明了完全解析 Tα 和 Dα 线的可行性。这些发现强调了 LIBS 在增强聚变装置中氘和氚滞留检测方面的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
6.10
自引率
12.10%
发文量
173
审稿时长
81 days
期刊介绍: Spectrochimica Acta Part B: Atomic Spectroscopy, is intended for the rapid publication of both original work and reviews in the following fields: Atomic Emission (AES), Atomic Absorption (AAS) and Atomic Fluorescence (AFS) spectroscopy; Mass Spectrometry (MS) for inorganic analysis covering Spark Source (SS-MS), Inductively Coupled Plasma (ICP-MS), Glow Discharge (GD-MS), and Secondary Ion Mass Spectrometry (SIMS). Laser induced atomic spectroscopy for inorganic analysis, including non-linear optical laser spectroscopy, covering Laser Enhanced Ionization (LEI), Laser Induced Fluorescence (LIF), Resonance Ionization Spectroscopy (RIS) and Resonance Ionization Mass Spectrometry (RIMS); Laser Induced Breakdown Spectroscopy (LIBS); Cavity Ringdown Spectroscopy (CRDS), Laser Ablation Inductively Coupled Plasma Atomic Emission Spectroscopy (LA-ICP-AES) and Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS). X-ray spectrometry, X-ray Optics and Microanalysis, including X-ray fluorescence spectrometry (XRF) and related techniques, in particular Total-reflection X-ray Fluorescence Spectrometry (TXRF), and Synchrotron Radiation-excited Total reflection XRF (SR-TXRF). Manuscripts dealing with (i) fundamentals, (ii) methodology development, (iii)instrumentation, and (iv) applications, can be submitted for publication.
期刊最新文献
Assessment of acupuncture's effectiveness in treating gulf war illness using laser induced breakdown spectroscopy and inductively coupled plasma mass spectrometry Characterization of the distribution of mineral elements in chromium-stressed rice (Oryza sativa L.) leaves based on laser-induced breakdown spectroscopy and data augmentation Rapid determination of 90Sr in seawater using a novel porous crown-based resin and tandem quadrupole ICP-MS/MS in cool plasma and O2-He mode Consideration of spectral interference in total reflection X-ray fluorescence analysis using a limited number of calibration samples: Case study of ocean polymetallic nodules Signal enhancement with double-pulse LIBS on biological samples and better discrimination of tissues through machine learning algorithms
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1