Myoelectric Fatigue and Motor-Unit Firing Patterns During Sinusoidal Vibration Superimposed on Low-Intensity Isometric Contraction

IF 4.8 2区 医学 Q2 ENGINEERING, BIOMEDICAL IEEE Transactions on Neural Systems and Rehabilitation Engineering Pub Date : 2024-10-01 DOI:10.1109/TNSRE.2024.3471856
Zuyu Du;Yaodan Xu;Anyi Cheng;Yibin Jin;Lin Xu
{"title":"Myoelectric Fatigue and Motor-Unit Firing Patterns During Sinusoidal Vibration Superimposed on Low-Intensity Isometric Contraction","authors":"Zuyu Du;Yaodan Xu;Anyi Cheng;Yibin Jin;Lin Xu","doi":"10.1109/TNSRE.2024.3471856","DOIUrl":null,"url":null,"abstract":"Vibration exercise (VE) has shown promising results for improving muscle strength and power performance when superimposed on high-level muscle contraction. However, low-level contraction may be more preferable in many rehabilitation programs due to the weakness of the patients. Unfortunately, the effects and underlying physiological mechanisms of VE superimposed on low-level contraction are unclear. This study aims to investigate the fatiguing effects and motor unit (MU) firing patterns during VE with low-level muscle contraction. Twenty-one healthy participants performed 60-s isometric contraction of the upper limb under a baseline force at \n<inline-formula> <tex-math>${30}\\%$ </tex-math></inline-formula>\n maximum voluntary contraction and superimposed vibration with an amplitude of \n<inline-formula> <tex-math>${50}\\%$ </tex-math></inline-formula>\n baseline and different frequencies at 0 Hz (control), 15, 25, 35, and 45 Hz. High-density surface electromyography (EMG) was recorded on the biceps brachii. The decay in muscle fiber conduction velocity, calculated in 3-s sliding windows, was employed as an indicator of myoelectric fatigue. MU firing patterns were obtained by decomposing the high-density EMG into MU spike trains. VE, particularly at 25 Hz, produces increased myoelectric fatigue as compared to the control condition. Besides, synchronized MU discharges are observed at the vibration frequency for 15- and 25-Hz VE and the sub-harmonics for 35- and 45-Hz VE. Furthermore, VE-induced increase in MU synchronization (as compared to control) seems to decrease with myoelectric fatigue. Significance: Our findings suggest that VE may be a suitable modality for rehabilitation programs, providing useful insights for subscribing appropriate VE training protocols.","PeriodicalId":13419,"journal":{"name":"IEEE Transactions on Neural Systems and Rehabilitation Engineering","volume":"32 ","pages":"3773-3781"},"PeriodicalIF":4.8000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10701468","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Neural Systems and Rehabilitation Engineering","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10701468/","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Vibration exercise (VE) has shown promising results for improving muscle strength and power performance when superimposed on high-level muscle contraction. However, low-level contraction may be more preferable in many rehabilitation programs due to the weakness of the patients. Unfortunately, the effects and underlying physiological mechanisms of VE superimposed on low-level contraction are unclear. This study aims to investigate the fatiguing effects and motor unit (MU) firing patterns during VE with low-level muscle contraction. Twenty-one healthy participants performed 60-s isometric contraction of the upper limb under a baseline force at ${30}\%$ maximum voluntary contraction and superimposed vibration with an amplitude of ${50}\%$ baseline and different frequencies at 0 Hz (control), 15, 25, 35, and 45 Hz. High-density surface electromyography (EMG) was recorded on the biceps brachii. The decay in muscle fiber conduction velocity, calculated in 3-s sliding windows, was employed as an indicator of myoelectric fatigue. MU firing patterns were obtained by decomposing the high-density EMG into MU spike trains. VE, particularly at 25 Hz, produces increased myoelectric fatigue as compared to the control condition. Besides, synchronized MU discharges are observed at the vibration frequency for 15- and 25-Hz VE and the sub-harmonics for 35- and 45-Hz VE. Furthermore, VE-induced increase in MU synchronization (as compared to control) seems to decrease with myoelectric fatigue. Significance: Our findings suggest that VE may be a suitable modality for rehabilitation programs, providing useful insights for subscribing appropriate VE training protocols.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
正弦振动叠加低强度等长收缩时的肌电疲劳和运动单元点火模式。
振动训练(VE)与高水平肌肉收缩叠加后,在改善肌肉力量和动力表现方面取得了可喜的成果。然而,在许多康复计划中,由于患者身体虚弱,低水平收缩可能更为可取。遗憾的是,VE 叠加低水平收缩的效果和潜在生理机制尚不清楚。本研究旨在探讨在低水平肌肉收缩下进行 VE 时的疲劳效应和运动单位(MU)的发射模式。21 名健康参与者在基线力为最大自主收缩力 30% 的情况下进行了 60 秒的上肢等长收缩,并叠加了振幅为基线力 50%、频率为 0 Hz(对照组)、15、25、35 和 45 Hz 的不同振动。对肱二头肌进行了高密度表面肌电图(EMG)记录。以 3 秒滑动窗口计算的肌纤维传导速度衰减被用作肌电疲劳的指标。通过将高密度肌电图分解为 MU 尖峰序列,可获得 MU 发火模式。与对照组相比,VE(尤其是 25 Hz 频率)会增加肌电疲劳。此外,在 15 赫兹和 25 赫兹 VE 的振动频率以及 35 赫兹和 45 赫兹 VE 的次谐波频率下,均可观察到同步 MU 放电。此外,VE 引起的 MU 同步性增加(与对照组相比)似乎会随着肌电疲劳而减少。意义重大:我们的研究结果表明,VE可能是一种适合康复计划的模式,为制定适当的VE训练方案提供了有益的启示。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
8.60
自引率
8.20%
发文量
479
审稿时长
6-12 weeks
期刊介绍: Rehabilitative and neural aspects of biomedical engineering, including functional electrical stimulation, acoustic dynamics, human performance measurement and analysis, nerve stimulation, electromyography, motor control and stimulation; and hardware and software applications for rehabilitation engineering and assistive devices.
期刊最新文献
Hidden Brain State-Based Internal Evaluation Using Kernel Inverse Reinforcement Learning in Brain-Machine Interfaces Electrophysiological Evidence on Mirror Therapy for Promoting Perceptuo-Motor Processes in Stroke Patients A Novel Dual-Model Adaptive Continuous Learning Strategy for Wrist-sEMG Real-Time Gesture Recognition Long-Term Gait-Balance Monitoring Artificial Intelligence System for Various Terrain Types Semi-Autonomous Continuous Robotic Arm Control Using an Augmented Reality Brain-Computer Interface
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1