Ten-year clinical and radiological outcomes with a vitamin E-infused highly cross-linked polyethylene acetabular cup.

IF 2.8 Q1 ORTHOPEDICS Bone & Joint Open Pub Date : 2024-10-03 DOI:10.1302/2633-1462.510.BJO-2023-0179.R1
Yama Afghanyar, Bedjan Afghanyar, Lennard Loweg, Philipp Drees, Erol Gercek, Jens Dargel, Philipp Rehbein, Karl P Kutzner
{"title":"Ten-year clinical and radiological outcomes with a vitamin E-infused highly cross-linked polyethylene acetabular cup.","authors":"Yama Afghanyar, Bedjan Afghanyar, Lennard Loweg, Philipp Drees, Erol Gercek, Jens Dargel, Philipp Rehbein, Karl P Kutzner","doi":"10.1302/2633-1462.510.BJO-2023-0179.R1","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>Limited implant survival due to aseptic cup loosening is most commonly responsible for revision total hip arthroplasty (THA). Advances in implant designs and materials have been crucial in addressing those challenges. Vitamin E-infused highly cross-linked polyethylene (VEPE) promises strong wear resistance, high oxidative stability, and superior mechanical strength. Although VEPE monoblock cups have shown good mid-term performance and excellent wear patterns, long-term results remain unclear. This study evaluated migration and wear patterns and clinical and radiological outcomes at a minimum of ten years' follow-up.</p><p><strong>Methods: </strong>This prospective observational study investigated 101 cases of primary THA over a mean duration of 129 months (120 to 149). At last follow-up, 57 cases with complete clinical and radiological outcomes were evaluated. In all cases, the acetabular component comprised an uncemented titanium particle-coated VEPE monoblock cup. Patients were assessed clinically and radiologically using the Harris Hip Score, visual analogue scale (pain and satisfaction), and an anteroposterior radiograph. Cup migration and polyethylene wear were measured using Einzel-Bild-Röntgen-Analyze software. All complications and associated treatments were documented until final follow-up.</p><p><strong>Results: </strong>Clinical assessment showed persistent major improvement in all scores. On radiological assessment, only one case showed a lucent line (without symptoms). At last follow-up, wear and migration were below the critical thresholds. No cup-related revisions were needed, indicating an outstanding survival rate of 100%.</p><p><strong>Conclusion: </strong>Isoelastic VEPE cups offer high success rates and may prevent osteolysis, aseptic loosening, and the need for revision surgeries in the long term. However, longer follow-up is needed to validate our findings and confirm the advantages offered by this cup.</p>","PeriodicalId":34103,"journal":{"name":"Bone & Joint Open","volume":null,"pages":null},"PeriodicalIF":2.8000,"publicationDate":"2024-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11446611/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bone & Joint Open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1302/2633-1462.510.BJO-2023-0179.R1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Aims: Limited implant survival due to aseptic cup loosening is most commonly responsible for revision total hip arthroplasty (THA). Advances in implant designs and materials have been crucial in addressing those challenges. Vitamin E-infused highly cross-linked polyethylene (VEPE) promises strong wear resistance, high oxidative stability, and superior mechanical strength. Although VEPE monoblock cups have shown good mid-term performance and excellent wear patterns, long-term results remain unclear. This study evaluated migration and wear patterns and clinical and radiological outcomes at a minimum of ten years' follow-up.

Methods: This prospective observational study investigated 101 cases of primary THA over a mean duration of 129 months (120 to 149). At last follow-up, 57 cases with complete clinical and radiological outcomes were evaluated. In all cases, the acetabular component comprised an uncemented titanium particle-coated VEPE monoblock cup. Patients were assessed clinically and radiologically using the Harris Hip Score, visual analogue scale (pain and satisfaction), and an anteroposterior radiograph. Cup migration and polyethylene wear were measured using Einzel-Bild-Röntgen-Analyze software. All complications and associated treatments were documented until final follow-up.

Results: Clinical assessment showed persistent major improvement in all scores. On radiological assessment, only one case showed a lucent line (without symptoms). At last follow-up, wear and migration were below the critical thresholds. No cup-related revisions were needed, indicating an outstanding survival rate of 100%.

Conclusion: Isoelastic VEPE cups offer high success rates and may prevent osteolysis, aseptic loosening, and the need for revision surgeries in the long term. However, longer follow-up is needed to validate our findings and confirm the advantages offered by this cup.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
注入维生素 E 的高交联聚乙烯髋臼杯的十年临床和放射学疗效。
目的:无菌髋臼杯松动导致的植入物存活率有限是翻修全髋关节置换术(THA)最常见的原因。植入物设计和材料的进步对解决这些难题至关重要。注入维生素 E 的高交联聚乙烯(VEPE)具有很强的耐磨性、高氧化稳定性和卓越的机械强度。虽然 VEPE 单体杯显示出良好的中期性能和出色的磨损模式,但长期结果仍不明确。本研究评估了至少十年随访的移位和磨损模式以及临床和放射学结果:这项前瞻性观察研究调查了101例初级THA病例,平均病程为129个月(120至149个月)。在最后一次随访中,对57例病例的临床和放射学结果进行了评估。所有病例的髋臼组件均为非骨水泥钛颗粒涂层VEPE单体髋臼杯。采用哈里斯髋关节评分(Harris Hip Score)、视觉模拟量表(疼痛和满意度)和前后位X光片对患者进行临床和放射学评估。使用Einzel-Bild-Röntgen-Analyze软件测量髋臼杯移位和聚乙烯磨损情况。所有并发症和相关治疗均记录在案,直至最终随访:结果:临床评估显示,所有评分均有显著改善。放射学评估显示,只有一个病例出现了透明线(无症状)。在最后一次随访中,磨损和移位均低于临界值。没有人需要进行与杯相关的翻修,这表明存活率高达 100%:结论:等弹力VEPE髋臼杯的成功率很高,长期使用可防止骨溶解、无菌性松动和翻修手术。然而,要验证我们的研究结果并确认这种髋臼杯的优势,还需要更长时间的随访。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Bone & Joint Open
Bone & Joint Open ORTHOPEDICS-
CiteScore
5.10
自引率
0.00%
发文量
0
审稿时长
8 weeks
期刊最新文献
Unexpected positive cultures in aseptic revision hip and knee arthroplasty. Ten-year clinical and radiological outcomes with a vitamin E-infused highly cross-linked polyethylene acetabular cup. Large variability in degree of constraint of reverse total shoulder arthroplasty liners between different implant systems. Robotic-navigated spinal decompression procedures: the next frontier. Minimally invasive robotic-assisted lumbar laminectomy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1