Safety and efficacy of coated flow diverters in the treatment of cerebral aneurysms during single antiplatelet therapy: A multicenter study.

IF 1.5 4区 医学 Q4 CLINICAL NEUROLOGY Interventional Neuroradiology Pub Date : 2024-10-03 DOI:10.1177/15910199241286542
Lukas Goertz, Sophia Hohenstatt, Dominik F Vollherbst, Charlotte S Weyland, Omid Nikoubashman, Christian Gronemann, Muriel Pflaeging, Eberhard Siebert, Georg Bohner, David Zopfs, Marc Schlamann, Thomas Liebig, Franziska Dorn, Martin Wiesmann, Markus A Möhlenbruch, Christoph Kabbasch
{"title":"Safety and efficacy of coated flow diverters in the treatment of cerebral aneurysms during single antiplatelet therapy: A multicenter study.","authors":"Lukas Goertz, Sophia Hohenstatt, Dominik F Vollherbst, Charlotte S Weyland, Omid Nikoubashman, Christian Gronemann, Muriel Pflaeging, Eberhard Siebert, Georg Bohner, David Zopfs, Marc Schlamann, Thomas Liebig, Franziska Dorn, Martin Wiesmann, Markus A Möhlenbruch, Christoph Kabbasch","doi":"10.1177/15910199241286542","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>This multicenter study evaluates the safety and efficacy of coated flow diverters (cFDs) for the treatment of cerebral aneurysms under single antiplatelet therapy (SAPT).</p><p><strong>Methods: </strong>This is a retrospective, observational study of 41 patients (median age: 58 years) with 41 aneurysms (median size: 7 mm, 29 [71%] saccular, 9 [22%] ruptured) treated with cFDs at four neurovascular centers between 2020 and 2023. Scheduled cases received continuous SAPT starting seven days before the procedure. Emergency cases were treated with tirofiban followed by SAPT loading. The safety endpoint was ischemic complications occurring during the procedure and within four months of clinical follow-up.</p><p><strong>Results: </strong>The Pipeline Vantage or Flex Shield was used in 26 (63%) procedures, the FRED X in 12 (29%), the p48/64 Hydrophilic Polymer Coating in 2 (5%), and the Derivo Embolization Device 2heal in 1 (2%). Single antiplatelet therapy consisted of prasugrel in 27 (66%) patients, ticagrelor in 9 (22%), and ASA in 5 (12%). There were 2 (5%) early ischemic complications (one minor stroke and one transient ischemic attack). There were no late ischemic complications in the four-month follow-up of 35 patients. The six dropouts included four nontreatment-related deaths after subarachnoid hemorrhage and two patients with a poor outcome after subarachnoid hemorrhage. Complete and favorable occlusion rates (median: 7 months) were 75% (27/36) and 89% (32/36), respectively.</p><p><strong>Conclusions: </strong>Coated flow diverter implantation in the setting of SAPT was safe and effective and warrants confirmation in a prospective comparative trial.</p>","PeriodicalId":49174,"journal":{"name":"Interventional Neuroradiology","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2024-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional Neuroradiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15910199241286542","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: This multicenter study evaluates the safety and efficacy of coated flow diverters (cFDs) for the treatment of cerebral aneurysms under single antiplatelet therapy (SAPT).

Methods: This is a retrospective, observational study of 41 patients (median age: 58 years) with 41 aneurysms (median size: 7 mm, 29 [71%] saccular, 9 [22%] ruptured) treated with cFDs at four neurovascular centers between 2020 and 2023. Scheduled cases received continuous SAPT starting seven days before the procedure. Emergency cases were treated with tirofiban followed by SAPT loading. The safety endpoint was ischemic complications occurring during the procedure and within four months of clinical follow-up.

Results: The Pipeline Vantage or Flex Shield was used in 26 (63%) procedures, the FRED X in 12 (29%), the p48/64 Hydrophilic Polymer Coating in 2 (5%), and the Derivo Embolization Device 2heal in 1 (2%). Single antiplatelet therapy consisted of prasugrel in 27 (66%) patients, ticagrelor in 9 (22%), and ASA in 5 (12%). There were 2 (5%) early ischemic complications (one minor stroke and one transient ischemic attack). There were no late ischemic complications in the four-month follow-up of 35 patients. The six dropouts included four nontreatment-related deaths after subarachnoid hemorrhage and two patients with a poor outcome after subarachnoid hemorrhage. Complete and favorable occlusion rates (median: 7 months) were 75% (27/36) and 89% (32/36), respectively.

Conclusions: Coated flow diverter implantation in the setting of SAPT was safe and effective and warrants confirmation in a prospective comparative trial.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
涂层血流分流器在单一抗血小板疗法中治疗脑动脉瘤的安全性和有效性:一项多中心研究。
研究目的这项多中心研究评估了涂膜血流分流器(cFDs)在单一抗血小板疗法(SAPT)下治疗脑动脉瘤的安全性和有效性:这是一项回顾性观察研究,研究对象是2020年至2023年期间在四家神经血管中心接受cFD治疗的41例动脉瘤患者(中位年龄:58岁)(中位大小:7毫米,29例[71%]为囊性动脉瘤,9例[22%]为破裂动脉瘤)。预定病例在手术前七天开始接受连续的 SAPT 治疗。急诊病例接受替罗非班治疗,然后加载 SAPT。安全性终点是手术过程中和临床随访四个月内发生的缺血性并发症:26例(63%)手术使用了Pipeline Vantage或Flex Shield,12例(29%)使用了FRED X,2例(5%)使用了p48/64亲水聚合物涂层,1例(2%)使用了Derivo栓塞装置2heal。单一抗血小板疗法包括普拉格雷(27 例,占 66%)、替格瑞洛(9 例,占 22%)和 ASA(5 例,占 12%)。有 2 例(5%)早期缺血性并发症(1 例轻微中风和 1 例短暂性脑缺血发作)。在对35名患者进行的为期四个月的随访中,没有出现后期缺血性并发症。六名退出治疗的患者包括四名蛛网膜下腔出血后非治疗相关死亡的患者和两名蛛网膜下腔出血后效果不佳的患者。完全闭塞率和良好闭塞率(中位:7个月)分别为75%(27/36)和89%(32/36):在 SAPT 情况下植入涂层分流器是安全有效的,值得在前瞻性比较试验中加以确认。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Interventional Neuroradiology
Interventional Neuroradiology CLINICAL NEUROLOGY-RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
CiteScore
3.60
自引率
11.80%
发文量
192
审稿时长
6-12 weeks
期刊介绍: Interventional Neuroradiology (INR) is a peer-reviewed clinical practice journal documenting the current state of interventional neuroradiology worldwide. INR publishes original clinical observations, descriptions of new techniques or procedures, case reports, and articles on the ethical and social aspects of related health care. Original research published in INR is related to the practice of interventional neuroradiology...
期刊最新文献
Emergent endovascular treatment versus medical treatment for acute large vessel occlusions with nondisabling symptoms. Performance assessment of the Surpass Evolve flow diverter for the treatment of intracranial aneurysms: A systematic review and meta-analysis. Safety and efficacy of coated flow diverters in the treatment of cerebral aneurysms during single antiplatelet therapy: A multicenter study. Silk vista baby flow diversion beyond the circle of Willis: A single-center experience with long-term outcomes. Barriers to stroke treatment: The price of long-distance from thrombectomy centers.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1