Minyong Lee, Donggun Kim, Yongbeom Shin, Jeongwoo Lee, Jae W. Lee
{"title":"Circulation of self-supplied water for significant energy recovery through heat integration","authors":"Minyong Lee, Donggun Kim, Yongbeom Shin, Jeongwoo Lee, Jae W. Lee","doi":"10.1016/j.ecmx.2024.100740","DOIUrl":null,"url":null,"abstract":"<div><div>This study introduces an overhead heat-integrated distillation column (OHIDiC), a novel approach that maximizes heat recovery by multiple heat exchanges and product circulation. By utilizing the overhead vapor as a direct heat source, low-temperature feed and product water were used as cooling agents, thereby significantly reducing the condenser duty and reliance on cooling utilities. Additionally, the heated feed transfers heat to the column, leading to a substantial reduction of reboiler heat duty. Some of the heated product water is recycled back to the decanter for product cycling, while the rest is released as the final product. This circulation process ensures a continuous coolant supply, which contributes the reduction of condenser duty. Two processes were considered in this study, utilizing the water product from a non-reactive, and from a reactive separation within the system. When applied to the separation of a water-dodecanol mixture, OHIDiC reduced the condenser duty by 69.21% compared to a traditional distillation column, with a 31.46% reduction in the total utility consumption. When reactive distillation was incorporated into the OHIDiC, the higher overhead vapor temperature facilitated high heat transfer in the multiple heat exchange sections, thereby significantly reducing the total thermal load. This resulted in a reduction of up to 46.96% in total heat duty and a 36.06% decrease in CO<sub>2</sub> emissions. These findings confirm that the OHIDiC achieves significant energy savings through the utilization of process-derived substances, with pronounced benefits when the temperature of the overhead vapor becomes higher.</div></div>","PeriodicalId":37131,"journal":{"name":"Energy Conversion and Management-X","volume":"24 ","pages":"Article 100740"},"PeriodicalIF":7.1000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energy Conversion and Management-X","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2590174524002186","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0
Abstract
This study introduces an overhead heat-integrated distillation column (OHIDiC), a novel approach that maximizes heat recovery by multiple heat exchanges and product circulation. By utilizing the overhead vapor as a direct heat source, low-temperature feed and product water were used as cooling agents, thereby significantly reducing the condenser duty and reliance on cooling utilities. Additionally, the heated feed transfers heat to the column, leading to a substantial reduction of reboiler heat duty. Some of the heated product water is recycled back to the decanter for product cycling, while the rest is released as the final product. This circulation process ensures a continuous coolant supply, which contributes the reduction of condenser duty. Two processes were considered in this study, utilizing the water product from a non-reactive, and from a reactive separation within the system. When applied to the separation of a water-dodecanol mixture, OHIDiC reduced the condenser duty by 69.21% compared to a traditional distillation column, with a 31.46% reduction in the total utility consumption. When reactive distillation was incorporated into the OHIDiC, the higher overhead vapor temperature facilitated high heat transfer in the multiple heat exchange sections, thereby significantly reducing the total thermal load. This resulted in a reduction of up to 46.96% in total heat duty and a 36.06% decrease in CO2 emissions. These findings confirm that the OHIDiC achieves significant energy savings through the utilization of process-derived substances, with pronounced benefits when the temperature of the overhead vapor becomes higher.
期刊介绍:
Energy Conversion and Management: X is the open access extension of the reputable journal Energy Conversion and Management, serving as a platform for interdisciplinary research on a wide array of critical energy subjects. The journal is dedicated to publishing original contributions and in-depth technical review articles that present groundbreaking research on topics spanning energy generation, utilization, conversion, storage, transmission, conservation, management, and sustainability.
The scope of Energy Conversion and Management: X encompasses various forms of energy, including mechanical, thermal, nuclear, chemical, electromagnetic, magnetic, and electric energy. It addresses all known energy resources, highlighting both conventional sources like fossil fuels and nuclear power, as well as renewable resources such as solar, biomass, hydro, wind, geothermal, and ocean energy.