Investigating dehumidification and heating performance in a dual evaporator heat pump system for electric vehicles

IF 3.5 2区 工程技术 Q1 ENGINEERING, MECHANICAL International Journal of Refrigeration-revue Internationale Du Froid Pub Date : 2024-09-27 DOI:10.1016/j.ijrefrig.2024.09.024
Kang Li , Mingfei Tan , Yuan Man , Hua Zhang , Binlin Dou , Ni Liu , Tianjiao Zhang , Qize He , Lin Su , Soheil Mohtaram
{"title":"Investigating dehumidification and heating performance in a dual evaporator heat pump system for electric vehicles","authors":"Kang Li ,&nbsp;Mingfei Tan ,&nbsp;Yuan Man ,&nbsp;Hua Zhang ,&nbsp;Binlin Dou ,&nbsp;Ni Liu ,&nbsp;Tianjiao Zhang ,&nbsp;Qize He ,&nbsp;Lin Su ,&nbsp;Soheil Mohtaram","doi":"10.1016/j.ijrefrig.2024.09.024","DOIUrl":null,"url":null,"abstract":"<div><div>In cold, moisture-rich winter environments, window fogging represents a substantial safety hazard for drivers. Electric vehicles often incorporate heat pump systems to address challenges such as dehumidification and heating specific to cold weather. Therefore, it is essential to evaluate the dehumidification and heating efficiency of these systems through focused research. This study presents a dual-evaporator heat pump system designed specifically for electric vehicles, equipped with two distinct modes for dehumidification and heating. The research examines how factors such as inlet air volume and the degree of opening of the electronic expansion valve affect the system's dehumidification and heating performance. Experimental analyses were conducted to explore the system's response under various conditions of inlet air humidity and compressor speed in both modes. Results suggest that increasing inlet air volume improves dehumidification effectiveness but may reduce heating performance. Likewise, a wider opening of the electronic expansion valve enhances heating but could decrease dehumidification efficiency. Importantly, the study indicates that when the relative humidity of the inlet air exceeds 70 %, a single evaporator mode is more effective for dehumidification. However, when the relative humidity is below 70 %, the dual evaporator mode is more advantageous, showing better heating performance.</div></div>","PeriodicalId":14274,"journal":{"name":"International Journal of Refrigeration-revue Internationale Du Froid","volume":"168 ","pages":"Pages 620-631"},"PeriodicalIF":3.5000,"publicationDate":"2024-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Refrigeration-revue Internationale Du Froid","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0140700724003360","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0

Abstract

In cold, moisture-rich winter environments, window fogging represents a substantial safety hazard for drivers. Electric vehicles often incorporate heat pump systems to address challenges such as dehumidification and heating specific to cold weather. Therefore, it is essential to evaluate the dehumidification and heating efficiency of these systems through focused research. This study presents a dual-evaporator heat pump system designed specifically for electric vehicles, equipped with two distinct modes for dehumidification and heating. The research examines how factors such as inlet air volume and the degree of opening of the electronic expansion valve affect the system's dehumidification and heating performance. Experimental analyses were conducted to explore the system's response under various conditions of inlet air humidity and compressor speed in both modes. Results suggest that increasing inlet air volume improves dehumidification effectiveness but may reduce heating performance. Likewise, a wider opening of the electronic expansion valve enhances heating but could decrease dehumidification efficiency. Importantly, the study indicates that when the relative humidity of the inlet air exceeds 70 %, a single evaporator mode is more effective for dehumidification. However, when the relative humidity is below 70 %, the dual evaporator mode is more advantageous, showing better heating performance.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
研究电动汽车双蒸发器热泵系统的除湿和加热性能
在寒冷、湿度大的冬季环境中,车窗起雾对驾驶员的安全构成了极大的威胁。电动汽车通常采用热泵系统来应对寒冷天气下的除湿和加热等挑战。因此,有必要通过重点研究来评估这些系统的除湿和加热效率。本研究介绍了专为电动汽车设计的双蒸发器热泵系统,该系统配备两种不同的除湿和加热模式。研究探讨了进气量和电子膨胀阀开启程度等因素如何影响系统的除湿和制热性能。研究人员进行了实验分析,以探讨系统在两种模式下不同的进气湿度和压缩机转速条件下的反应。结果表明,增加进气量可以提高除湿效果,但可能会降低制热性能。同样,电子膨胀阀开度越大,制热效果越好,但可能会降低除湿效率。重要的是,研究表明,当入口空气的相对湿度超过 70% 时,单蒸发器模式的除湿效果更好。然而,当相对湿度低于 70% 时,双蒸发器模式更具优势,显示出更好的制热性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
7.30
自引率
12.80%
发文量
363
审稿时长
3.7 months
期刊介绍: The International Journal of Refrigeration is published for the International Institute of Refrigeration (IIR) by Elsevier. It is essential reading for all those wishing to keep abreast of research and industrial news in refrigeration, air conditioning and associated fields. This is particularly important in these times of rapid introduction of alternative refrigerants and the emergence of new technology. The journal has published special issues on alternative refrigerants and novel topics in the field of boiling, condensation, heat pumps, food refrigeration, carbon dioxide, ammonia, hydrocarbons, magnetic refrigeration at room temperature, sorptive cooling, phase change materials and slurries, ejector technology, compressors, and solar cooling. As well as original research papers the International Journal of Refrigeration also includes review articles, papers presented at IIR conferences, short reports and letters describing preliminary results and experimental details, and letters to the Editor on recent areas of discussion and controversy. Other features include forthcoming events, conference reports and book reviews. Papers are published in either English or French with the IIR news section in both languages.
期刊最新文献
Review and prospect of air source heat pump research: A bibliometric insight Simulation analysis on ejector performance with inclusion of chevrons in primary nozzle An assessment of service quality for cold-chain logistics in air freight: A Perception-Expectation gap model based on fuzzy Best-Worst Method CFD-based unsteady simulation and performance analysis of scroll compressor A semi-empirical model of frost formation on a cryogenic surface cooled from ambient temperature under forced convection condition
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1