Mengjing Xu, Boyang Shi, Haofeng Li, Xiaohan Mai, Lan Mi, Jiong Ma, Xiangdong Zhu, Guowei Wang, Yiyan Fei
{"title":"Development of a carboxymethyl chitosan functionalized slide for small molecule detection using oblique-incidence reflectivity difference technology.","authors":"Mengjing Xu, Boyang Shi, Haofeng Li, Xiaohan Mai, Lan Mi, Jiong Ma, Xiangdong Zhu, Guowei Wang, Yiyan Fei","doi":"10.1364/BOE.534563","DOIUrl":null,"url":null,"abstract":"<p><p>Label-free optical biosensors have become powerful tools in the study of biomolecular interactions without the need for labels. High throughput and low detection limit are desirable for rapid and accurate biomolecule detection. The oblique-incidence reflectivity difference (OI-RD) technique is capable of detecting thousands of biomolecular interactions in a high-throughput mode, specifically for biomolecules larger than 1000 Da. In order to enhance the detection capability of OI-RD for small molecules (typically < 500 Da), we have developed a three-dimensional biochip that utilized carboxymethyl chitosan (CMCS) functionalized slides. By investigating various factors such as sonication time, protein immobilization time, CMCS molecular weight, and glutaraldehyde (GA) functionalization time, we have achieved a detection limit of 6.8 pM for avidin (68 kDa). Furthermore, accurate detection of D-biotin with a molecular weight of 244 Da has also been achieved. This paper presents an effective solution for achieving both high throughput and low detection limits using the OI-RD technique in the field of biomolecular interaction detection.</p>","PeriodicalId":8969,"journal":{"name":"Biomedical optics express","volume":"15 10","pages":"5947-5959"},"PeriodicalIF":2.9000,"publicationDate":"2024-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11482164/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical optics express","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1364/BOE.534563","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
Abstract
Label-free optical biosensors have become powerful tools in the study of biomolecular interactions without the need for labels. High throughput and low detection limit are desirable for rapid and accurate biomolecule detection. The oblique-incidence reflectivity difference (OI-RD) technique is capable of detecting thousands of biomolecular interactions in a high-throughput mode, specifically for biomolecules larger than 1000 Da. In order to enhance the detection capability of OI-RD for small molecules (typically < 500 Da), we have developed a three-dimensional biochip that utilized carboxymethyl chitosan (CMCS) functionalized slides. By investigating various factors such as sonication time, protein immobilization time, CMCS molecular weight, and glutaraldehyde (GA) functionalization time, we have achieved a detection limit of 6.8 pM for avidin (68 kDa). Furthermore, accurate detection of D-biotin with a molecular weight of 244 Da has also been achieved. This paper presents an effective solution for achieving both high throughput and low detection limits using the OI-RD technique in the field of biomolecular interaction detection.
期刊介绍:
The journal''s scope encompasses fundamental research, technology development, biomedical studies and clinical applications. BOEx focuses on the leading edge topics in the field, including:
Tissue optics and spectroscopy
Novel microscopies
Optical coherence tomography
Diffuse and fluorescence tomography
Photoacoustic and multimodal imaging
Molecular imaging and therapies
Nanophotonic biosensing
Optical biophysics/photobiology
Microfluidic optical devices
Vision research.