Effects of Time-Elapsed Bleaching on the Surface and Mechanical Properties of Dentin Substrate Using Hydrogen Peroxide-Free Nanohydroxyapatite Gel.

IF 6.6 2区 医学 Q1 NANOSCIENCE & NANOTECHNOLOGY International Journal of Nanomedicine Pub Date : 2024-10-12 eCollection Date: 2024-01-01 DOI:10.2147/IJN.S478930
Aftab Ahmed Khan, Abdulaziz Abdullah AlKhureif, Manal Almutairi, Abrar Nasser Bin Nooh, Saeed Awod Bin Hassan, Yasser M Alqahtani
{"title":"Effects of Time-Elapsed Bleaching on the Surface and Mechanical Properties of Dentin Substrate Using Hydrogen Peroxide-Free Nanohydroxyapatite Gel.","authors":"Aftab Ahmed Khan, Abdulaziz Abdullah AlKhureif, Manal Almutairi, Abrar Nasser Bin Nooh, Saeed Awod Bin Hassan, Yasser M Alqahtani","doi":"10.2147/IJN.S478930","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>There is a critical need to address concerns surrounding the potential impact of bleaching gels specifically on the tooth substrate. Therefore, this laboratory investigation aimed to assess the impact of a hydrogen peroxide (HP)-free bleaching (HiSmile<sup>TM</sup>) in comparison to an HP-based bleaching (Opalescence Regular<sup>TM</sup>) on the surface and mechanical characteristics of tooth substrate.</p><p><strong>Methods: </strong>Sixty sound human premolar teeth were sectioned to produce dentin fragments and divided into two primary groups based on the bleaching agent used. Each group was subdivided into three subgroups (n = 10) per distinct bleaching regimens: (T<sub>1</sub>) fragments underwent a 7-day immersion in distilled water at 37°C without any bleaching treatment, (T<sub>2</sub>) fragments underwent a 7-day immersion in distilled water at 37°C, with the application of bleaching gel occurring on the seventh day for 10 minutes, and (T<sub>3</sub>) fragments underwent a bleaching regimen for seven consecutive days, each session lasting for 10 minutes. The initial and final evaluations of surface roughness, nano-hardness, and elastic modulus were performed. Following the bleaching regimens of T<sub>3</sub>, a composite stub was fabricated on the dentin fragments for the shear bond strength (SBS) test. Statistical testing was accomplished using the analysis of variance (P < 0.05).</p><p><strong>Results: </strong>HP-based bleaching gel showed significant differences between measurement intervals in surface roughness, elastic modulus, and SBS parameters (P < 0.05). In contrast, HP-free bleaching gel showed insignificant differences within the group (P > 0.05). The SBS between dentin-composite was significantly affected with the use of HP-based bleaching gel, while HP-free bleaching gel showed insignificant difference between measurement intervals. The qualitative validation of the treatment's impact was further demonstrated using the scanning electron microscopy.</p><p><strong>Conclusion: </strong>The findings suggest that the bonding stability of composite restorations to dentin may be compromised after bleaching with an HP-based gel, whereas immediate bonding procedures can be safely conducted following the application of an HP-free bleaching gel.</p>","PeriodicalId":14084,"journal":{"name":"International Journal of Nanomedicine","volume":"19 ","pages":"10307-10317"},"PeriodicalIF":6.6000,"publicationDate":"2024-10-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11485028/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Nanomedicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2147/IJN.S478930","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"NANOSCIENCE & NANOTECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: There is a critical need to address concerns surrounding the potential impact of bleaching gels specifically on the tooth substrate. Therefore, this laboratory investigation aimed to assess the impact of a hydrogen peroxide (HP)-free bleaching (HiSmileTM) in comparison to an HP-based bleaching (Opalescence RegularTM) on the surface and mechanical characteristics of tooth substrate.

Methods: Sixty sound human premolar teeth were sectioned to produce dentin fragments and divided into two primary groups based on the bleaching agent used. Each group was subdivided into three subgroups (n = 10) per distinct bleaching regimens: (T1) fragments underwent a 7-day immersion in distilled water at 37°C without any bleaching treatment, (T2) fragments underwent a 7-day immersion in distilled water at 37°C, with the application of bleaching gel occurring on the seventh day for 10 minutes, and (T3) fragments underwent a bleaching regimen for seven consecutive days, each session lasting for 10 minutes. The initial and final evaluations of surface roughness, nano-hardness, and elastic modulus were performed. Following the bleaching regimens of T3, a composite stub was fabricated on the dentin fragments for the shear bond strength (SBS) test. Statistical testing was accomplished using the analysis of variance (P < 0.05).

Results: HP-based bleaching gel showed significant differences between measurement intervals in surface roughness, elastic modulus, and SBS parameters (P < 0.05). In contrast, HP-free bleaching gel showed insignificant differences within the group (P > 0.05). The SBS between dentin-composite was significantly affected with the use of HP-based bleaching gel, while HP-free bleaching gel showed insignificant difference between measurement intervals. The qualitative validation of the treatment's impact was further demonstrated using the scanning electron microscopy.

Conclusion: The findings suggest that the bonding stability of composite restorations to dentin may be compromised after bleaching with an HP-based gel, whereas immediate bonding procedures can be safely conducted following the application of an HP-free bleaching gel.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用无过氧化氢纳米羟基磷灰石凝胶进行延时漂白对牙本质基底表面和机械性能的影响
简介:目前亟需解决漂白凝胶对牙齿基质的潜在影响问题。因此,本实验室调查旨在评估不含过氧化氢(HP)的漂白剂(HiSmileTM)与含HP的漂白剂(Opalescence RegularTM)相比对牙齿基质表面和机械特性的影响:对 60 颗健全的人类前臼齿进行切片,制作牙本质碎片,并根据所使用的漂白剂将其分为两组。每组又按不同的漂白方案分为三个亚组(n = 10):(T1)牙片在 37°C 的蒸馏水中浸泡 7 天,不进行任何漂白处理;(T2)牙片在 37°C 的蒸馏水中浸泡 7 天,第七天涂漂白凝胶,每次 10 分钟;(T3)牙片连续漂白 7 天,每次 10 分钟。对表面粗糙度、纳米硬度和弹性模量进行了初步和最终评估。T3 漂白疗程结束后,在牙本质碎片上制作复合材料桩,进行剪切粘接强度(SBS)测试。统计检验采用方差分析法(P < 0.05):结果:基于 HP 的漂白凝胶在表面粗糙度、弹性模量和 SBS 参数方面显示出不同测量区间的显著差异(P < 0.05)。相比之下,不含 HP 的漂白凝胶在组内差异不显著(P > 0.05)。使用基于 HP 的漂白凝胶后,牙本质-复合材料之间的 SBS 受到明显影响,而不含 HP 的漂白凝胶在不同测量间隔之间的差异不明显。结论:研究结果表明,牙本质与复合材料之间的 SBS 在使用 HP 漂白凝胶后会受到明显影响,而不含 HP 漂白凝胶的牙本质与复合材料之间的 SBS 在不同测量时间段内差异不明显:结论:研究结果表明,使用含HP的漂白凝胶进行漂白后,复合树脂修复体与牙本质的粘接稳定性可能会受到影响,而使用不含HP的漂白凝胶则可以安全地进行即刻粘接。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
International Journal of Nanomedicine
International Journal of Nanomedicine NANOSCIENCE & NANOTECHNOLOGY-PHARMACOLOGY & PHARMACY
CiteScore
14.40
自引率
3.80%
发文量
511
审稿时长
1.4 months
期刊介绍: The International Journal of Nanomedicine is a globally recognized journal that focuses on the applications of nanotechnology in the biomedical field. It is a peer-reviewed and open-access publication that covers diverse aspects of this rapidly evolving research area. With its strong emphasis on the clinical potential of nanoparticles in disease diagnostics, prevention, and treatment, the journal aims to showcase cutting-edge research and development in the field. Starting from now, the International Journal of Nanomedicine will not accept meta-analyses for publication.
期刊最新文献
Prospective Application of Mesenchymal Stem Cell-Derived Exosomes in the Treatment of Disseminated Intravascular Coagulation. Augment of Ferroptosis with Photothermal Enhanced Fenton Reaction and Glutathione Inhibition for Tumor Synergistic Nano-Catalytic Therapy. How Nanoparticles Help in Combating Chronic Wound Biofilms Infection? Therapeutic Potential of Ginger Exosome-Like Nanoparticles for Alleviating Periodontitis-Induced Tissue Damage. Unveiling the Hidden Risks: An Update Decade-Long Analysis of Abraxane-Related Adverse Events from the FAERS Database.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1