High-frequency irreversible electroporation ablation for the prostate in Beagle dogs.

IF 1.9 3区 医学 Q4 ANDROLOGY Translational andrology and urology Pub Date : 2024-09-30 Epub Date: 2024-09-26 DOI:10.21037/tau-24-108
Rong Xing, Shiyu Ji, Xinyi Li, Tianying Gong, Qi Jiang
{"title":"High-frequency irreversible electroporation ablation for the prostate in Beagle dogs.","authors":"Rong Xing, Shiyu Ji, Xinyi Li, Tianying Gong, Qi Jiang","doi":"10.21037/tau-24-108","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Ablation procedures have garnered significant attention as a minimally invasive treatment of prostate diseases. However, the feasibility and safety of applying high-frequency irreversible electroporation (H-FIRE) to ablate the Beagle prostate for benign prostatic hyperplasia (BPH) treatment have not been thoroughly explored, the appropriate range of parameters has not been determined. In order to ensure the feasibility and safety of prostate ablation surgery, we conducted a study using Beagle dogs as subjects to investigate prostate tissue.</p><p><strong>Methods: </strong>We utilized a composite steep pulse therapy device to perform ablations on 26 lateral lobes of the prostate in 13 Beagles, employing various parameters for different needle distances. The effectiveness of this device was assessed through the observation of the ablation area, intraoperative muscle tremors, postoperative hematological examination, and gross inspection.</p><p><strong>Results: </strong>The findings of our study revealed that 1,000 to 2,000 v/cm in electric field strength, combined with 5 µs pulse width and pulse number 100, is a safe parameter range for ablation of prostate tissue. At the same time, the large electric field strength (2,000 v/cm) has the best ablation effect with the biggest continuous and thorough ablation area. All parameters of H-FIRE were safe for Beagles.</p><p><strong>Conclusions: </strong>H-FIRE ablation for prostate is safe and effective in dogs, which has the potential to be a useful addition to the range of minimally invasive treatments available for the treatment of BPH against this backdrop of increasing surgical practice.</p>","PeriodicalId":23270,"journal":{"name":"Translational andrology and urology","volume":"13 9","pages":"2016-2026"},"PeriodicalIF":1.9000,"publicationDate":"2024-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11491217/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Translational andrology and urology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.21037/tau-24-108","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/26 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ANDROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Ablation procedures have garnered significant attention as a minimally invasive treatment of prostate diseases. However, the feasibility and safety of applying high-frequency irreversible electroporation (H-FIRE) to ablate the Beagle prostate for benign prostatic hyperplasia (BPH) treatment have not been thoroughly explored, the appropriate range of parameters has not been determined. In order to ensure the feasibility and safety of prostate ablation surgery, we conducted a study using Beagle dogs as subjects to investigate prostate tissue.

Methods: We utilized a composite steep pulse therapy device to perform ablations on 26 lateral lobes of the prostate in 13 Beagles, employing various parameters for different needle distances. The effectiveness of this device was assessed through the observation of the ablation area, intraoperative muscle tremors, postoperative hematological examination, and gross inspection.

Results: The findings of our study revealed that 1,000 to 2,000 v/cm in electric field strength, combined with 5 µs pulse width and pulse number 100, is a safe parameter range for ablation of prostate tissue. At the same time, the large electric field strength (2,000 v/cm) has the best ablation effect with the biggest continuous and thorough ablation area. All parameters of H-FIRE were safe for Beagles.

Conclusions: H-FIRE ablation for prostate is safe and effective in dogs, which has the potential to be a useful addition to the range of minimally invasive treatments available for the treatment of BPH against this backdrop of increasing surgical practice.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
比格犬前列腺高频不可逆电穿孔消融术
背景:作为前列腺疾病的一种微创治疗方法,消融术已引起广泛关注。然而,应用高频不可逆电穿孔术(H-FIRE)消融比格犬前列腺以治疗良性前列腺增生症(BPH)的可行性和安全性尚未得到深入探讨,适当的参数范围也尚未确定。为了确保前列腺消融手术的可行性和安全性,我们以比格犬为研究对象,对前列腺组织进行了研究:方法:我们使用一种复合陡峭脉冲治疗设备对 13 只比格犬的 26 个前列腺侧叶进行了消融,并针对不同的针距采用了不同的参数。通过观察消融区域、术中肌肉震颤、术后血液学检查和大体检查评估了该设备的有效性:我们的研究结果表明,电场强度为 1,000 至 2,000 v/cm、脉冲宽度为 5 µs、脉冲数为 100 是消融前列腺组织的安全参数范围。同时,大电场强度(2,000 v/cm)的消融效果最好,消融区域最大且连续彻底。H-FIRE的所有参数对比格犬都是安全的:H-FIRE前列腺消融术对狗是安全有效的,在外科手术日益增多的背景下,它有可能成为治疗良性前列腺增生症的微创疗法的有益补充。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
4.10
自引率
5.00%
发文量
80
期刊介绍: ranslational Andrology and Urology (Print ISSN 2223-4683; Online ISSN 2223-4691; Transl Androl Urol; TAU) is an open access, peer-reviewed, bi-monthly journal (quarterly published from Mar.2012 - Dec. 2014). The main focus of the journal is to describe new findings in the field of translational research of Andrology and Urology, provides current and practical information on basic research and clinical investigations of Andrology and Urology. Specific areas of interest include, but not limited to, molecular study, pathology, biology and technical advances related to andrology and urology. Topics cover range from evaluation, prevention, diagnosis, therapy, prognosis, rehabilitation and future challenges to urology and andrology. Contributions pertinent to urology and andrology are also included from related fields such as public health, basic sciences, education, sociology, and nursing.
期刊最新文献
Robotic ureteral reconstruction of non-absorbable clip erosion into the ureter: a case series. Successful sperm retrieval by microdissection testicular sperm extraction in a man with partial AZFb deletion: a case report. The dartocavernous stitch surgical technique for prevention of recurrent phimosis in obese patients presenting for circumcision. Time-sensitive elements in elective treatment of urinary lithiasis: a narrative review. Understanding general public and healthcare provider knowledge gaps in male factor infertility.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1