Dynamic prediction of pregnancy outcome after previous stillbirth or perinatal death: pilot study to establish proof-of-concept and explore method feasibility.

IF 6.1 1区 医学 Q1 ACOUSTICS Ultrasound in Obstetrics & Gynecology Pub Date : 2024-11-01 Epub Date: 2024-10-15 DOI:10.1002/uog.29104
A E P Heazell, N Graham, M J Parkes, J Wilkinson
{"title":"Dynamic prediction of pregnancy outcome after previous stillbirth or perinatal death: pilot study to establish proof-of-concept and explore method feasibility.","authors":"A E P Heazell, N Graham, M J Parkes, J Wilkinson","doi":"10.1002/uog.29104","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To establish proof-of-concept for the dynamic prediction of adverse pregnancy outcome in women with a history of stillbirth or perinatal death, repeatedly throughout the pregnancy.</p><p><strong>Methods: </strong>A retrospective cohort study of women in a subsequent pregnancy following previous perinatal loss, who received antenatal care at a tertiary hospital between January 2014 and December 2017, was used as the basis for exploratory prognostic model development. Models were developed to repeatedly predict a composite adverse outcome (stillbirth or neonatal death, 5-min Apgar score < 7, umbilical artery pH ≤ 7.05, admission to the neonatal intensive care unit for longer than 24 h, preterm birth (< 37 completed weeks) or birth weight < 10<sup>th</sup> centile) using the findings of sequential ultrasound scans for fetal biometry and umbilical and uterine artery Doppler.</p><p><strong>Results: </strong>In total, 506 participants were eligible, of whom 504 were included in the analysis. An adverse pregnancy outcome was experienced by 110 (22%) participants. The ability to predict the composite outcome using repeated head circumference and estimated fetal weight measurements improved as the pregnancy progressed (e.g. area under the receiver-operating-characteristics curve improved from 0.59 at 24 weeks' gestation to 0.74 at 36 weeks' gestation), supporting proof-of-concept. Predictors to include in dynamic prediction models were identified, including ultrasound measurements of fetal biometry, umbilical and uterine artery Doppler and placental size and shape.</p><p><strong>Conclusion: </strong>The present study supports proof-of-concept for dynamic prediction of adverse outcome in pregnancy following prior stillbirth or perinatal death, which could be used to identify risks earlier in pregnancy, while highlighting methodological challenges and requirements for subsequent large-scale model development studies. © 2024 The Author(s). Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.</p>","PeriodicalId":23454,"journal":{"name":"Ultrasound in Obstetrics & Gynecology","volume":" ","pages":"613-619"},"PeriodicalIF":6.1000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasound in Obstetrics & Gynecology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/uog.29104","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/15 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To establish proof-of-concept for the dynamic prediction of adverse pregnancy outcome in women with a history of stillbirth or perinatal death, repeatedly throughout the pregnancy.

Methods: A retrospective cohort study of women in a subsequent pregnancy following previous perinatal loss, who received antenatal care at a tertiary hospital between January 2014 and December 2017, was used as the basis for exploratory prognostic model development. Models were developed to repeatedly predict a composite adverse outcome (stillbirth or neonatal death, 5-min Apgar score < 7, umbilical artery pH ≤ 7.05, admission to the neonatal intensive care unit for longer than 24 h, preterm birth (< 37 completed weeks) or birth weight < 10th centile) using the findings of sequential ultrasound scans for fetal biometry and umbilical and uterine artery Doppler.

Results: In total, 506 participants were eligible, of whom 504 were included in the analysis. An adverse pregnancy outcome was experienced by 110 (22%) participants. The ability to predict the composite outcome using repeated head circumference and estimated fetal weight measurements improved as the pregnancy progressed (e.g. area under the receiver-operating-characteristics curve improved from 0.59 at 24 weeks' gestation to 0.74 at 36 weeks' gestation), supporting proof-of-concept. Predictors to include in dynamic prediction models were identified, including ultrasound measurements of fetal biometry, umbilical and uterine artery Doppler and placental size and shape.

Conclusion: The present study supports proof-of-concept for dynamic prediction of adverse outcome in pregnancy following prior stillbirth or perinatal death, which could be used to identify risks earlier in pregnancy, while highlighting methodological challenges and requirements for subsequent large-scale model development studies. © 2024 The Author(s). Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
动态预测死产或围产期死亡后的妊娠结局:旨在验证概念和探索方法可行性的试点研究。
目的对有死胎或围产期死亡史的妇女在整个孕期反复出现的不良妊娠结局进行动态预测的概念验证:方法:以一项回顾性队列研究为基础,对2014年1月至2017年12月期间在一家三甲医院接受产前护理的围产期死亡产妇进行探索性预后模型开发。利用胎儿生物测量、脐动脉和子宫动脉多普勒的连续超声扫描结果,建立了重复预测综合不良结局(死胎或新生儿死亡、5分钟Apgar评分th百分位数)的模型:共有 506 人符合条件,其中 504 人被纳入分析。110名参与者(22%)出现了不良妊娠结局。随着妊娠的进展,使用重复头围和估计胎儿体重测量值预测综合结果的能力有所提高(例如,受体运算特征曲线下面积从妊娠24周时的0.59提高到妊娠36周时的0.74),支持概念验证。结论:本研究支持概念验证:本研究支持对死胎或围产儿死亡后妊娠不良结局进行动态预测的概念验证,可用于在妊娠早期识别风险,同时强调了后续大规模模型开发研究在方法学方面的挑战和要求。© 2024 作者姓名妇产科超声》由 John Wiley & Sons Ltd 代表国际妇产科超声学会出版。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
12.30
自引率
14.10%
发文量
891
审稿时长
1 months
期刊介绍: Ultrasound in Obstetrics & Gynecology (UOG) is the official journal of the International Society of Ultrasound in Obstetrics and Gynecology (ISUOG) and is considered the foremost international peer-reviewed journal in the field. It publishes cutting-edge research that is highly relevant to clinical practice, which includes guidelines, expert commentaries, consensus statements, original articles, and systematic reviews. UOG is widely recognized and included in prominent abstract and indexing databases such as Index Medicus and Current Contents.
期刊最新文献
Angle between vein of Galen and straight sinus: a novel marker on microvascular flow imaging for prenatal assessment of tentorium cerebelli position. Congenital heart defects during COVID-19 pandemic. Transabdominal sonographic sliding signs for preoperative prediction of dense intra-abdominal adhesions in women undergoing repeat Cesarean delivery. Ultrasound assessment of lymph nodes for staging of gynecological cancer: consensus opinion on terminology and examination technique. Comprehensive prenatal ultrasound for surgical risk assessment: differentiating placenta accreta spectrum from uterine scar dehiscence for improved clinical decision-making.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1