{"title":"A novel tapered quartz tuning fork-based laser spectroscopy sensing","authors":"Yufei Ma, Shunda Qiao, Runqiu Wang, Ying He, Chao Fang, Tiantian Liang","doi":"10.1063/5.0214874","DOIUrl":null,"url":null,"abstract":"A novel tapered quartz tuning fork (QTF) was designed to enhance its stress magnitude and charge distribution in QTF-based laser spectroscopy, which had a low resonant frequency of 7.83 kHz and a wide fork gap for long energy accumulation time and easy optical alignment. Compared to the reported rectangular QTF, this tapered QTF transfers the maximum stress position from the root to the middle to improve its sensing performance. Furthermore, the unique design eliminates the 90° right angles typically found in standard QTFs, which often lead to undesired “webs” and “facets” during the etching process. This design minimizes performance degradation by reducing the presence of residual unexpected materials. QTF-based laser spectroscopy of quartz-enhanced photoacoustic spectroscopy (QEPAS) and light-induced thermoelastic spectroscopy (LITES) were adopted to verify its performance. Compared with the widely used standard QTF, the total surface charge of the tapered QTF was improved 5.08 times and 5.69 times in QEPAS and LITES simulations, respectively. Experiments revealed that this tapered QTF-based QEPAS sensor had a 3.02 times improvement in signal-to-noise-ratio (SNR) compared to the standard QTF-based system. Adding an acoustic micro-resonator to this tapered QTF-based QEPAS sensor improved the signal level by 97.20 times. The minimum detection limit (MDL) for acetylene (C2H2) detection was determined to be 16.45 ppbv. In the LITES technique, compared to the standard QTF, this tapered QTF-based sensor had a 3.60 times improvement in SNR. The MDL for C2H2 detection was determined to be 146.39 ppbv.","PeriodicalId":8200,"journal":{"name":"Applied physics reviews","volume":"40 1","pages":""},"PeriodicalIF":11.9000,"publicationDate":"2024-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied physics reviews","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.1063/5.0214874","RegionNum":1,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"PHYSICS, APPLIED","Score":null,"Total":0}
引用次数: 0
Abstract
A novel tapered quartz tuning fork (QTF) was designed to enhance its stress magnitude and charge distribution in QTF-based laser spectroscopy, which had a low resonant frequency of 7.83 kHz and a wide fork gap for long energy accumulation time and easy optical alignment. Compared to the reported rectangular QTF, this tapered QTF transfers the maximum stress position from the root to the middle to improve its sensing performance. Furthermore, the unique design eliminates the 90° right angles typically found in standard QTFs, which often lead to undesired “webs” and “facets” during the etching process. This design minimizes performance degradation by reducing the presence of residual unexpected materials. QTF-based laser spectroscopy of quartz-enhanced photoacoustic spectroscopy (QEPAS) and light-induced thermoelastic spectroscopy (LITES) were adopted to verify its performance. Compared with the widely used standard QTF, the total surface charge of the tapered QTF was improved 5.08 times and 5.69 times in QEPAS and LITES simulations, respectively. Experiments revealed that this tapered QTF-based QEPAS sensor had a 3.02 times improvement in signal-to-noise-ratio (SNR) compared to the standard QTF-based system. Adding an acoustic micro-resonator to this tapered QTF-based QEPAS sensor improved the signal level by 97.20 times. The minimum detection limit (MDL) for acetylene (C2H2) detection was determined to be 16.45 ppbv. In the LITES technique, compared to the standard QTF, this tapered QTF-based sensor had a 3.60 times improvement in SNR. The MDL for C2H2 detection was determined to be 146.39 ppbv.
期刊介绍:
Applied Physics Reviews (APR) is a journal featuring articles on critical topics in experimental or theoretical research in applied physics and applications of physics to other scientific and engineering branches. The publication includes two main types of articles:
Original Research: These articles report on high-quality, novel research studies that are of significant interest to the applied physics community.
Reviews: Review articles in APR can either be authoritative and comprehensive assessments of established areas of applied physics or short, timely reviews of recent advances in established fields or emerging areas of applied physics.