Hamees A. Adawy, Maha A. Hegazy, Samah S. Saad, Amr M. Bekhet, Shereen A. Boltia
{"title":"Greenness assessment of a molecularly imprinted polymeric sensor based on a bio-inspired polymer","authors":"Hamees A. Adawy, Maha A. Hegazy, Samah S. Saad, Amr M. Bekhet, Shereen A. Boltia","doi":"10.1186/s13065-024-01313-0","DOIUrl":null,"url":null,"abstract":"<div><p>Methyldopa, a synthesized dopamine substitute with phenolic, amine, and carboxylic groups, was used to create a selective molecular imprinted polymer (MIP) for detecting formoterol fumarate dihydrate (FFD), a long-acting beta2-agonist for asthma and COPD. The bio-inspired polymer (MD) was electro-grafted onto a pencil graphite electrode (PGE) using cyclic voltammetry in a phosphate buffer (pH 6.5). An indirect method involving a redox probe (ferrocyanide/ferricyanide) and differential pulse voltammetry measured FFD binding to the MIP’s 3D cavities. The sensor showed a linear response range from 1 × 10⁻⁹ M to 2 × 10⁻¹⁰ M, with a detection limit of 1.7 × 10⁻¹¹ M. The polymethyldopa (PMD) and FFD interaction was assessed by UV spectroscopy, and the method was validated per ICH guidelines. Green analytical approaches, including RGB and GAPI, were also implemented. The goal was to use advances in molecularly imprinted polymers to develop a more precise and selective electrochemical sensor for FFD quantification.</p></div>","PeriodicalId":496,"journal":{"name":"BMC Chemistry","volume":"18 1","pages":""},"PeriodicalIF":4.3000,"publicationDate":"2024-10-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://bmcchem.biomedcentral.com/counter/pdf/10.1186/s13065-024-01313-0","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Chemistry","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1186/s13065-024-01313-0","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Methyldopa, a synthesized dopamine substitute with phenolic, amine, and carboxylic groups, was used to create a selective molecular imprinted polymer (MIP) for detecting formoterol fumarate dihydrate (FFD), a long-acting beta2-agonist for asthma and COPD. The bio-inspired polymer (MD) was electro-grafted onto a pencil graphite electrode (PGE) using cyclic voltammetry in a phosphate buffer (pH 6.5). An indirect method involving a redox probe (ferrocyanide/ferricyanide) and differential pulse voltammetry measured FFD binding to the MIP’s 3D cavities. The sensor showed a linear response range from 1 × 10⁻⁹ M to 2 × 10⁻¹⁰ M, with a detection limit of 1.7 × 10⁻¹¹ M. The polymethyldopa (PMD) and FFD interaction was assessed by UV spectroscopy, and the method was validated per ICH guidelines. Green analytical approaches, including RGB and GAPI, were also implemented. The goal was to use advances in molecularly imprinted polymers to develop a more precise and selective electrochemical sensor for FFD quantification.
期刊介绍:
BMC Chemistry, formerly known as Chemistry Central Journal, is now part of the BMC series journals family.
Chemistry Central Journal has served the chemistry community as a trusted open access resource for more than 10 years – and we are delighted to announce the next step on its journey. In January 2019 the journal has been renamed BMC Chemistry and now strengthens the BMC series footprint in the physical sciences by publishing quality articles and by pushing the boundaries of open chemistry.