Stig Steen, Audrius Paskevicius, Qiuming Liao, Erik Steen
{"title":"<i>Ex vivo</i> evaluation of the whole heart function allowing selective investigation of the right and left heart.","authors":"Stig Steen, Audrius Paskevicius, Qiuming Liao, Erik Steen","doi":"10.1080/14017431.2024.2418084","DOIUrl":null,"url":null,"abstract":"<p><p><i>Objectives</i>. The aim was to demonstrate a reliable <i>ex vivo</i> method to test the function of the whole heart. <i>Design</i>. Pigs of varying sizes (44-80 kg) were exposed to dose response of adrenaline. Blood pressures and cardiac output were measured. The explanted hearts were tested in a novel <i>ex vivo</i> system to see if we could replicate the <i>in vivo</i> values at maximal adrenaline stimulation. The perfusion solution was STEEN Solution™ with erythrocytes and continuous infusion of essential drugs. In contrast to normal body circulation which is sequential, the heart evaluation system is divided into left and right heart circuits which are operating in parallel, making it possible to test the right and left heart individually or as a whole. The system provides coronary flow measurements. The nonlinear dynamic resistances are constructed to stabilize systolic and diastolic pressures in a broad range and independently from cardiac output. It is important for the functional evaluation to avoid pumping help for the heart; therefore, atrial vortexes are constructed to minimize pump flow directionality and energy from entering atria. <i>Results. Ex vivo</i> evaluation was able to match the maximal <i>in vivo</i> effect of adrenaline on cardiac output and blood pressures. After 2 h of evaluation, the blood gases and lactate were normal and free haemoglobin was zero. Autopsy of the hearts showed no macroscopic pathology. <i>Conclusions.</i> The system is able to give a reliable functional evaluation of the heart <i>ex vivo</i>.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/14017431.2024.2418084","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/26 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives. The aim was to demonstrate a reliable ex vivo method to test the function of the whole heart. Design. Pigs of varying sizes (44-80 kg) were exposed to dose response of adrenaline. Blood pressures and cardiac output were measured. The explanted hearts were tested in a novel ex vivo system to see if we could replicate the in vivo values at maximal adrenaline stimulation. The perfusion solution was STEEN Solution™ with erythrocytes and continuous infusion of essential drugs. In contrast to normal body circulation which is sequential, the heart evaluation system is divided into left and right heart circuits which are operating in parallel, making it possible to test the right and left heart individually or as a whole. The system provides coronary flow measurements. The nonlinear dynamic resistances are constructed to stabilize systolic and diastolic pressures in a broad range and independently from cardiac output. It is important for the functional evaluation to avoid pumping help for the heart; therefore, atrial vortexes are constructed to minimize pump flow directionality and energy from entering atria. Results. Ex vivo evaluation was able to match the maximal in vivo effect of adrenaline on cardiac output and blood pressures. After 2 h of evaluation, the blood gases and lactate were normal and free haemoglobin was zero. Autopsy of the hearts showed no macroscopic pathology. Conclusions. The system is able to give a reliable functional evaluation of the heart ex vivo.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.