{"title":"DWI lesions after intracranial aneurysm treatment with contour or WEB-does the device matter?","authors":"Friederike Gärtner, Tristan Klintz, Sönke Peters, Justus Mahnke, Karim Mostafa, Fernando Bueno Neves, Johannes Hensler, Naomi Larsen, Olav Jansen, Fritz Wodarg","doi":"10.1177/15910199241290844","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>In this study, we report our experience with the occurrence of diffusion-weighted imaging (DWI) lesions following aneurysm treatment with Woven EndoBridge (WEB) device and Contour Neurovascular System in elective settings. We compared both techniques in a retrospective single-center analysis, to investigate whether there are significant differences in the incidence of microemboli depending on the device used.</p><p><strong>Materials and methods: </strong>Sixty-two cases treated with Contour were retrospectively compared with 84 WEB cases. Postinterventional MRI was performed in all patients within five days after the angiographic procedure. Only DWI lesions in the dependent vascular territory of the treated aneurysm were considered. Data on occurrence of DWI lesions, device implantation times as well as device change or repositions maneuvers were compared.</p><p><strong>Results: </strong>A total of 146 patients were included in this study. Postinterventional DWI lesions were detected in 33 of the 62 (53.2%) Contour cases and in 36 of the 84 (42.8%) WEB cases with an average lesion number of 1.70 ± 3.45 in our WEB group and 1.68 ± 2.53 in our Contour cohort. Neither periinterventional device changes nor device reposition maneuvers had a significant impact on the occurrence of DWI lesions. Although four patients experienced transient neurological deterioration, the DWI lesions were not clinically relevant at the time of discharge, as the patients' NIHSS remained stable compared to the preintervention NIHSS in the entire cohort. There was no statistically significant difference between the implantation times of WEB and Contour, although Contour could be implanted slightly faster.</p><p><strong>Conclusion: </strong>Aneurysm treatment with WEB or Contour results in a comparable numbers of procedure-related DWI lesions. This effect was consistent after adjustment for other demographic or technical variables.</p>","PeriodicalId":49174,"journal":{"name":"Interventional Neuroradiology","volume":" ","pages":"15910199241290844"},"PeriodicalIF":1.5000,"publicationDate":"2024-10-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11559872/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional Neuroradiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15910199241290844","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: In this study, we report our experience with the occurrence of diffusion-weighted imaging (DWI) lesions following aneurysm treatment with Woven EndoBridge (WEB) device and Contour Neurovascular System in elective settings. We compared both techniques in a retrospective single-center analysis, to investigate whether there are significant differences in the incidence of microemboli depending on the device used.

Materials and methods: Sixty-two cases treated with Contour were retrospectively compared with 84 WEB cases. Postinterventional MRI was performed in all patients within five days after the angiographic procedure. Only DWI lesions in the dependent vascular territory of the treated aneurysm were considered. Data on occurrence of DWI lesions, device implantation times as well as device change or repositions maneuvers were compared.

Results: A total of 146 patients were included in this study. Postinterventional DWI lesions were detected in 33 of the 62 (53.2%) Contour cases and in 36 of the 84 (42.8%) WEB cases with an average lesion number of 1.70 ± 3.45 in our WEB group and 1.68 ± 2.53 in our Contour cohort. Neither periinterventional device changes nor device reposition maneuvers had a significant impact on the occurrence of DWI lesions. Although four patients experienced transient neurological deterioration, the DWI lesions were not clinically relevant at the time of discharge, as the patients' NIHSS remained stable compared to the preintervention NIHSS in the entire cohort. There was no statistically significant difference between the implantation times of WEB and Contour, although Contour could be implanted slightly faster.

Conclusion: Aneurysm treatment with WEB or Contour results in a comparable numbers of procedure-related DWI lesions. This effect was consistent after adjustment for other demographic or technical variables.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用轮廓仪或 WEB 治疗颅内动脉瘤后的 DWI 病变--设备是否重要?
目的:在这项研究中,我们报告了在择期手术中使用 Woven EndoBridge(WEB)装置和 Contour 神经血管系统治疗动脉瘤后发生弥散加权成像(DWI)病变的经验。我们在一项回顾性单中心分析中比较了这两种技术,以研究微栓子的发生率是否因所使用的装置不同而存在显著差异:我们将 62 例使用 Contour 治疗的病例与 84 例 WEB 病例进行了回顾性比较。所有患者均在血管造影术后五天内进行了介入后核磁共振成像。只考虑治疗后动脉瘤依附血管区域内的 DWI 病变。比较了 DWI 病变发生率、设备植入时间以及设备更换或重新定位操作的数据:结果:本研究共纳入 146 例患者。62例Contour病例中有33例(53.2%)发现了介入后DWI病变,84例WEB病例中有36例(42.8%)发现了介入后DWI病变,WEB组平均病变数为(1.70 ± 3.45),Contour组平均病变数为(1.68 ± 2.53)。介入周围设备更换或设备重新定位操作对 DWI 病变的发生均无明显影响。虽然有四名患者出现了短暂的神经功能恶化,但出院时 DWI 病变与临床无关,因为患者的 NIHSS 与整个队列干预前的 NIHSS 相比保持稳定。WEB和Contour的植入时间在统计学上没有明显差异,但Contour的植入速度稍快:结论:使用WEB或Contour治疗动脉瘤时,与手术相关的DWI病变数量相当。结论:使用WEB或Contour治疗动脉瘤时,与手术相关的DWI病变数量相当,在调整了其他人口统计学或技术变量后,这种效果仍然一致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Interventional Neuroradiology
Interventional Neuroradiology CLINICAL NEUROLOGY-RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
CiteScore
3.60
自引率
11.80%
发文量
192
审稿时长
6-12 weeks
期刊介绍: Interventional Neuroradiology (INR) is a peer-reviewed clinical practice journal documenting the current state of interventional neuroradiology worldwide. INR publishes original clinical observations, descriptions of new techniques or procedures, case reports, and articles on the ethical and social aspects of related health care. Original research published in INR is related to the practice of interventional neuroradiology...
期刊最新文献
Circulating miRNA profiles as predictive biomarkers for aneurysm healing following endovascular treatment: a prospective study. "Chopperlysis": The effect of helicopter transport on reperfusion and outcomes in large vessel occlusion strokes. DWI lesions after intracranial aneurysm treatment with contour or WEB-does the device matter? Analysis of selective neurocritical care admission costs following elective endovascular treatment of unruptured intracranial aneurysms. Recognition of dural to pial supply in high-grade dural arteriovenous fistula: A technical note.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1